User Manual

UserManual

Digital Weighing Indicator

Digital Weighing Indicator

DIGITAL WEIGHING INDICATOR

- 9 -

DIGITAL WEIGHING INDICATOR

- 8 -

Counting

User Function Setting

1. 

In weighing mode, press [Func] to enter into the counting state. It will display “count”, and pressing the 

 

[*] key will display “C00000”. Then press [Tare] to move the digit directed by the small triangle, and the 

 

number corresponding with the small triangle will be increased one each time after pressing the [Zero] 

 

 key (it will enter into counting function mode after the sample quantity is input and [*] is pressed). 

 

“0” will be displayed and the counting indication will be activated. Press [Func] key to return to 

 

weighing mode. After entering counting mode, “count” will be displayed. Press [*] two times to enter 

 

counting mode directly and the indicator will display the previous result. (During this process, if ERR4 

 

is displayed, then sampling has failed, and the indicator will keep the result from the last sampling.

1. 

In weighing mode, hold and press [Func] for 5 seconds and it will enter user function setting 

 

mode (mode P). There are 12 modes from P1 to P12. Press [*] to choose the mode and press [Tare]  

 

to choose the parameter. The description of parameters is as follows: 

P1

kg — Lb change

X=1:

kg display

X=2:

Lb display

P2

automatically power off

X=1:

N/A

X=2:

Power off in 10 minutes

X=3:

Power off in 20 minutes

X=4:

Power off in 30 minutes

P3

Baud rate setting

X=1:

9600

X=2:

4800

X=3:

2400

X=4:

1200

P4

RS232 Net/Gross weight output option

X=1:

Net weight output

X=2:

Gross weight output

P5

RS232 output mode option

X=1:

No transmission (RS232 stop)

X=2:

Continuous transmission

X=3:

Continuous transmission when stable

X=4:

Command mode 
(Z:zero; T:tare;R:transmit weight data once time)

X=5:

Current loop output

X=6:

Keep for Printing

P6

Backlight setting

X=1:

No backlight

X=2:

Automatic backlight

X=3:

Backlight On

P7

Zero-tracking range

X=1:

0.5e

X=2:

1.0e

X=3:

1.5e

X=4:

2.0e

X=5:

2.5e

X=6:

3.0e

X=7:

5.0e

P8

Manual zero range

X=1:

2%FS

X=2:

4%FS

X=3:

10%FS

X=4:

20%FS

P9

Auto zero range

X=1:

2%FS

X=2:

4%FS

X=3:

10%FS

X=4:

20%FS

Summary of Contents for D1047067

Page 1: ...Digital Weighing Indicator User Manual WWW DEELAT COM ...

Page 2: ...Indication 13 Chargeable Battery 13 Maintenance 14 Notes 15 Model Deelat Floor Scale weighing indicator Accuracy GradeIII n 3000 Sample Rate 10 times second A D conversion Δ Load cell sensitivity 1 5 3mV V Scale interval 1 2 5 10 20 50 for selection Display 6 bits LCD 6 state indicating signals Scoreboard interface optional In serial output mode current loop signal transmission distance 50m Commun...

Page 3: ... come into counting mode Press this button to accumulating the weight in weighing mode Press this button for sample taking in counting mode Press this button to tare in weighing mode Press this button to zero in weighing mode Press this button to turn on off the scale Press this button to stay in weighing mode or Press this button to save move in set mode FUNC TARE ZERO Unit Kg Charge A12 COUNT FU...

Page 4: ... zero 2 If the displayed value deviates from the zero point but it is still within the manual zero range the ZERO key will return the indictor to zero If not within the manual zero range then the ZERO key will not function If this is the case please recalibrate or reset zero parameters 3 Only when a stable indication is displayed can the zero operation function 1 When the indicator is in weighing ...

Page 5: ... keep the result from the last sampling 1 In weighing mode hold and press Func for 5 seconds and it will enter user function setting mode mode P There are 12 modes from P1 to P12 Press to choose the mode and press Tare to choose the parameter The description of parameters is as follows P1 kg Lb change X 1 kg display X 2 Lb display P2 automatically power off X 1 N A X 2 Power off in 10 minutes X 3 ...

Page 6: ...e following the 1st is starting the bit the 10th is the stop bit and the middle are 8 data bits Communication mode as follows 1 In continuous mode The data transmitted is weight Gross weight or net weight The format of G W ww000 000kg or ww000 000lb The format of N W wn000 000kg or wn000 000lb Note The position of above decimal is decided by the decimal set on the indicator 2 In command mode The i...

Page 7: ...point full range and enter into the zero point calibration mode Press ZERO when the stable signal is on and it will display End and keep the original full range point calibration Press the calibration switch under the lead sealing board at the back of the indicator and it will save the setting and return to the weighing status 4 Fast calibration for full range point Fast calibration for full range...

Page 8: ...pt anti static measures 4 Do not clean the case of indicator with intensive solvents for example benzene and nitro oils 5 Liquid and conductive substances should not come into contact with the indicator otherwise the electronic components can be damaged and the user could get shocked 6 Make sure to cut off the power supply to the indicator and relevant devices before connecting and disconnecting a...

Page 9: ...WWW DEELAT COM ...

Reviews: