Maintenance

Notes

1. 

To ensure proper function of the indicator, it should not be placed directly under sunshine and 

 

should be placed in a well ventilated space.  

2. 

The indicator should not be installed in a place with severe dust or where vibrations are present 

3. 

The Load cell requires a solid connection with the indicator, and the system should always be 

 

grounded. The indicator must avoid coming into contact with electric and magnetic fields.  

 

• Avoid using the indicator in a place that has flammable gas or flammable steam:  

 

• In order to protect the operator, indicator and relevant device, you should mount a lightning rod 

 

    in thunderstorm prone geographic areas. 

 

• Load cell and indicator are static sensitive device, you must adopt anti static measures. 

4. 

Do not clean the case of indicator with intensive solvents (for example: benzene and nitro oils)  

5. 

Liquid and conductive substances should not come into contact with the indicator, otherwise the 

 

electronic components can be damaged and the user could get shocked.  

6. 

Make sure to cut off the power supply to the indicator and relevant devices before connecting 

 

and disconnecting any external devices.  

7. 

During operation, if major problems occur, operator must pull off the power supply plug immediately, 

 

and user should return this indicator for repair. Unauthorized manufacturers, repair centers, or users 

 

should NOT repair the scale on their own, otherwise further damage may occur.  

8. 

In order to prolong product life, please charge the cell fully before using it. If you don’t use the 

 

indicator for a long time, you must charge the cell every two months and for eight hours per 

 

charging time.  

9. 

Moving or installation must be performed carefully and avoid sudden movements, vibration, 

 

and bumps in order to protect the storage cell from being damaged.

Summary of Contents for D1047067

Page 1: ...Digital Weighing Indicator User Manual WWW DEELAT COM ...

Page 2: ...Indication 13 Chargeable Battery 13 Maintenance 14 Notes 15 Model Deelat Floor Scale weighing indicator Accuracy GradeIII n 3000 Sample Rate 10 times second A D conversion Δ Load cell sensitivity 1 5 3mV V Scale interval 1 2 5 10 20 50 for selection Display 6 bits LCD 6 state indicating signals Scoreboard interface optional In serial output mode current loop signal transmission distance 50m Commun...

Page 3: ... come into counting mode Press this button to accumulating the weight in weighing mode Press this button for sample taking in counting mode Press this button to tare in weighing mode Press this button to zero in weighing mode Press this button to turn on off the scale Press this button to stay in weighing mode or Press this button to save move in set mode FUNC TARE ZERO Unit Kg Charge A12 COUNT FU...

Page 4: ... zero 2 If the displayed value deviates from the zero point but it is still within the manual zero range the ZERO key will return the indictor to zero If not within the manual zero range then the ZERO key will not function If this is the case please recalibrate or reset zero parameters 3 Only when a stable indication is displayed can the zero operation function 1 When the indicator is in weighing ...

Page 5: ... keep the result from the last sampling 1 In weighing mode hold and press Func for 5 seconds and it will enter user function setting mode mode P There are 12 modes from P1 to P12 Press to choose the mode and press Tare to choose the parameter The description of parameters is as follows P1 kg Lb change X 1 kg display X 2 Lb display P2 automatically power off X 1 N A X 2 Power off in 10 minutes X 3 ...

Page 6: ...e following the 1st is starting the bit the 10th is the stop bit and the middle are 8 data bits Communication mode as follows 1 In continuous mode The data transmitted is weight Gross weight or net weight The format of G W ww000 000kg or ww000 000lb The format of N W wn000 000kg or wn000 000lb Note The position of above decimal is decided by the decimal set on the indicator 2 In command mode The i...

Page 7: ...point full range and enter into the zero point calibration mode Press ZERO when the stable signal is on and it will display End and keep the original full range point calibration Press the calibration switch under the lead sealing board at the back of the indicator and it will save the setting and return to the weighing status 4 Fast calibration for full range point Fast calibration for full range...

Page 8: ...pt anti static measures 4 Do not clean the case of indicator with intensive solvents for example benzene and nitro oils 5 Liquid and conductive substances should not come into contact with the indicator otherwise the electronic components can be damaged and the user could get shocked 6 Make sure to cut off the power supply to the indicator and relevant devices before connecting and disconnecting a...

Page 9: ...WWW DEELAT COM ...

Reviews: