background image

LED SeaLite

®

Operator’s Manual

5

Safety Symbols

In this operator’s manual and on the product, safety symbols are used to communicate important 

safety information. This section is provided to improve understanding of these symbols.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to 

avoid possible injury or death.

DANGER

 

indicates a hazardous situation which, if not avoided, could result in death or serious injury.

WARNING

 indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm.

CAUTION

 indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

 

NOTICE 

indicates information that relates to the protection of property.

This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information 

on the safe and proper operation of the equipment.

This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of 

eye injury.

This symbol indicates the risk of electrical shock.

 

 

DANGER

  

!

 

WARNING

  

 

CAUTION

NOTICE

 

This symbol indicates a risk of exposure to high brightness. 

 

UV and blue light can cause eye injury. Avoid exposure to eyes.

 

This symbol indicates high voltage.

 

This symbol indicates a potentially hot surface that may cause burns or ignition.

PRELIMIN

AR

Y

General Notes & Warnings

The LED SeaLite

®

 light is designed and built for years of 

reliable service.  

This light was thoroughly pressure tested prior to leaving 

the factory to confirm the integrity of the complete 

assembly.  While there should be no reason to repair the 

LED SeaLite, this light is designed to be completely field 

serviceable. No soldered wire connections or specialized 

tools are required. All o-rings use viton material and 

have an extended shelf life.

The LED SeaLite can run at full power in air. This light 

is equipped with thermal sensing circuitry which will 

automatically roll back the light output and prevent it 

from overheating.  The light will return to full brightness 

once it is submerged and allowed to cool.

 

WARNING

Modifying the light in any way may damage the light and 

void the warranty. 

Do not clean any part of the light with solvent or alcohol. 

Soapy water is recommended.

Reconfiguring the pin-out of the light is potentially 

dangerous to the operator and can cause significant 

damage to the light. Any change to the pin-out should 

be done only through consultation with the factory in 

order to provide proper documentation and new pin-

out labeling. Failure to do so will result in the loss of 

warranty coverage for the light.

  DANGER

 

When the LED SeaLite is operated in air, the light may 

reach temperatures in excess of 65° C (150° F). These 

temperatures may cause burns if the light is handled 

without personal protective equipment.

While operating in air, this light emits sufficient photonic 

energy to ignite combustible materials. When light is 

operating in air, take appropriate precautions.

Do not operate any high voltage electrical equipment in 

or around water without using proper safety equipment 

such as a Ground Fault Circuit Interrupter (GFCI) and an 

isolation transformer, especially when divers are in the 

water. 

Summary of Contents for LED SeaLite LSL-1000

Page 1: ... POWER LIGHT Operator s Manual T 858 576 1261 F 858 576 0219 4033 Ruffin Road San Diego CA 92123 1817 USA www deepsea com sales deepsea com Original Instruction PRELIM INARY LED Sealite 1000 2000 REV 02 13 17 ...

Page 2: ...C Dimming RS2324 RS4854 Phase Triac RS2324 RS4854 0 5V 0 10V 4 20mA Mechanical Specifications Housing Hard Anodized 6013 Aluminum Titanium Port Standard Sapphire Optional Acrylic Outer Diameter 63 0 mm 2 48 in Overall Length Without Connector Flood 88 5 mm 3 48 Spot 94 9 mm 3 73 in Weight in Air5 Flood 490 g Spot 510 g Flood 450 g Spot 470 g Weight in Water5 Flood 240 g Spot 260 g Flood 200 g Spot...

Page 3: ... 3 1 00 25 4 4x 1 4 20 OR 4x M6x1 3 73 94 9 5 01 127 3 2 48 63 0 3 10 78 7 1 60 40 6 1 59 40 3 SPOT 2 48 63 0 3 10 78 7 3 48 88 5 4 76 120 9 1 59 40 3 1 35 34 2 FLOOD mm inch Standard Endcap Bracket 4 32 109 7 5 59 142 1 2 48 63 0 3 10 78 7 1 60 40 6 1 59 40 3 SPOT 2 48 63 0 3 10 78 7 4 07 103 3 5 34 135 7 1 59 40 3 1 35 34 2 FLOOD mm inch PRELIM INARY ...

Page 4: ...otes Warnings 5 Pre Post Dive Inspection 5 Troubleshooting 6 RMA Procedure for Repair 6 Limited Warranty 6 Appendix A LSL 1000 Driver Characteristics 7 8 Appendix B LSL 2000 Driver Characteristics 9 10 Appendix C Dimming Curve 11 13 Appendix D Beam Patterns 14 Appendix E SeaSense Information 15 PRELIM INARY ...

Page 5: ... service This light was thoroughly pressure tested prior to leaving the factory to confirm the integrity of the complete assembly While there should be no reason to repair the LED SeaLite this light is designed to be completely field serviceable No soldered wire connections or specialized tools are required All o rings use viton material and have an extended shelf life The LED SeaLite can run at f...

Page 6: ...re DeepSea Power Light Inc to furnish such new parts Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code 2715 Pre Post Dive Inspection Check to make sure that the rear bulkhead connector mating connector and all mounting hardware are secure before deployment Check the following areas for previous damage wear or corrosion r...

Page 7: ...0 180 190 200 80 100 120 140 160 180 200 Input Power W rms Input Voltage V rms LSL 1000 Real Power vs RMS Input Voltage AC DC 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 80 100 120 140 160 180 200 220 Input Current A rms Input Voltage V rms LSL 1000 Peak RMS Current vs RMS Input Voltage AC DC PRELIM INARY ...

Page 8: ...00 110 120 130 140 150 160 Power Factor Input Voltage VAC LSL 1000 Power Factor vs RMS Input Voltage 0 50 100 0 50 100 0 50 100 10 C 5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C Light Output Ambient Water Temperature LSL 1000 Thermal Operating Limits 90VAC 120VAC 140VAC PRELIM INARY ...

Page 9: ... Power W Input Voltage VDC LSL 2000 Input Power vs DC Input Voltage Low Input Range High Input Range Low Output Range High Output Range 100 50 0 0 1 2 3 4 5 6 7 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Light Output Input Current A Input Voltage VDC LSL 2000 Input Current vs DC Input Voltage Low Input Range High Input Range Low Output Range High Output Range PRELIM INARY ...

Page 10: ...Lite Operator s Manual 10 0 50 100 0 50 100 0 50 100 10 C 5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C Light Output Ambient Water Temperature LSL 2000 Thermal Operating Limits 10VDC 20VDC 48VDC PRELIM INARY ...

Page 11: ... 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Light Output LOUT Command Value SeaSense Serial Dimming Curve 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 Light Output Phase Angle LSL 1000 TRIAC Phase Dimming Curve PRELIM INARY ...

Page 12: ...0 0V 0 5V 1 0V 1 5V 2 0V 2 5V 3 0V 3 5V 4 0V 4 5V 5 0V Light Output Dimming Voltage V LSL 2000 0 5V Analog Dimming Curve 0 10 20 30 40 50 60 70 80 90 100 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Light Output Dimming Voltage V LSL 2000 0 10V Analog Dimming Curve PRELIM INARY ...

Page 13: ...D SeaLite Operator s Manual 13 0 10 20 30 40 50 60 70 80 90 100 0mA 2mA 4mA 6mA 8mA 10mA 12mA 14mA 16mA 18mA 20mA Light Output Dimming Control Current mA LSL 2000 4 20mA Analog Dimming Curve PRELIM INARY ...

Page 14: ...e Flood LSL 1000 6KA DW 075 PV SUBMC3 5680 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 100 0 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Radial Lux Distribution Comparison 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 0 25 50 75 100 Degrees Output Angular Distribution PRELIM INARY ...

Page 15: ...ay be present in the LED SeaLite The SeaSense protocol allows for an unparalleled flexibility in the use and operation of the LED SeaLite Using the protocol operators and system integrators can Control the light output level and remap the dimming curve to fit application requirements Monitor system parameters and diagnostic information such as total run time internal temperature and number of powe...