background image

LED SeaLite

®

Operator’s Manual

6

All shipments should be sent to the address below:

DeepSea Power & Light 

Attn: RMA #### 

4033 Ruffin Road          

San Diego, CA 92123-1817 

U.S.A 

Tel: 858-576-1261 

Fax: 858-576-0219 

Email: RMA@deepsea.com

Limited Warranty

Seller warrants that the goods (except internal electronic 

components) sold under this contract will be free from 

defect in material and workmanship for a period of two 

years from the date of shipment from the factory, if they 

have been properly used. Internal electronic components 

are warranted for 90 days from the date of shipment 

from the factory, if they have been properly used. This 

warranty will be limited to the repair or replacement of 

parts and the necessary labor and services required 

to repair the goods. IT IS EXPRESSLY AGREED 

THAT THIS WARRANTY WILL BE IN LIEU OF ALL 

WARRANTIES OF FITNESS AND IN LIEU OF THE 

WARRANTY OF MERCHANTABILITY. This warranty 

is the exclusive and only warranty to pass with the 

goods under this contract. No agent, employee, or 

representative of the Seller has any authority to bind 

Seller to any information, representation, or warranty 

concerning the goods sold under this contract, and 

unless an affirmation, representation, or warranty 

made by an agent, employee, or representative is 

specifically included within this contract, it will not be 

enforceable by Buyer. If notice of defect is given to 

DeepSea Power & Light, Inc. within such 90 day or two-

year warranty period, the sole obligation of DeepSea 

Power & Light, Inc. shall be to furnish new or repaired 

parts free of charge in exchange for parts which have 

been proved defective and does not include any other 

costs such as the cost of removal of the defective part, 

installation, labor, or consequential damages of any 

kind, the exclusive remedy being to require DeepSea 

Power & Light, Inc. to furnish such new parts. Under 

no circumstances shall the Buyer be entitled to recover 

any incidental damages as that term is defined in 

Commercial Code §2715. 

Pre & Post Dive Inspection

Check to make sure that the rear bulkhead connector, 

mating connector, and all mounting hardware are secure 

before deployment. 

Check the following areas for previous damage, wear, 

or corrosion: rear bulkhead connector, power cable, and 

front port.

Rinse the LED SeaLite in fresh water after use.

After each deployment, carefully check to make sure the 

light is operational and has not flooded.  If it has flooded, 

the light can become internally pressurized upon 

surfacing and create a potential danger.  Additionally, 

if the power remains on when the light has partially 

flooded, it is possible for electrolytic generation of an 

explosive mixture of hydrogen and oxygen gases. Point 

the light away from persons and valuable equipment and 

make sure that the power is disconnected.

Troubleshooting

If the light stops working while underwater, assume that 

it has flooded.

If it has been determined that the light is not flooded, 

and if the light does not turn on during pre-deployment 

checks, check the input power cable/inline connector to 

make sure that correct voltage is being supplied and that 

the correct pin-out is being used. If the light still does 

not work, return it to DSPL using the RMA Procedure for 

Repair below.

RMA Procedure for Repair 

For warranty and non-warranty repairs, please contact 

DeepSea Power & Light for an RMA number prior to 

returning the item. Please have the light model number, 

serial number, and any other pertinent information along 

with a description of the problem on hand when calling, 

or include them in a fax or e-mail. 

When shipping the item, be sure that the freight is pre-

paid (CODs will not be accepted) and that the RMA 

number is clearly printed on the outside of the box.

www.deepsea.com

sales@deepsea.com

T: 800-487-3775

F: 858-576-0219

PRELIMIN

AR

Y

Summary of Contents for LED SeaLite LSL-1000

Page 1: ... POWER LIGHT Operator s Manual T 858 576 1261 F 858 576 0219 4033 Ruffin Road San Diego CA 92123 1817 USA www deepsea com sales deepsea com Original Instruction PRELIM INARY LED Sealite 1000 2000 REV 02 13 17 ...

Page 2: ...C Dimming RS2324 RS4854 Phase Triac RS2324 RS4854 0 5V 0 10V 4 20mA Mechanical Specifications Housing Hard Anodized 6013 Aluminum Titanium Port Standard Sapphire Optional Acrylic Outer Diameter 63 0 mm 2 48 in Overall Length Without Connector Flood 88 5 mm 3 48 Spot 94 9 mm 3 73 in Weight in Air5 Flood 490 g Spot 510 g Flood 450 g Spot 470 g Weight in Water5 Flood 240 g Spot 260 g Flood 200 g Spot...

Page 3: ... 3 1 00 25 4 4x 1 4 20 OR 4x M6x1 3 73 94 9 5 01 127 3 2 48 63 0 3 10 78 7 1 60 40 6 1 59 40 3 SPOT 2 48 63 0 3 10 78 7 3 48 88 5 4 76 120 9 1 59 40 3 1 35 34 2 FLOOD mm inch Standard Endcap Bracket 4 32 109 7 5 59 142 1 2 48 63 0 3 10 78 7 1 60 40 6 1 59 40 3 SPOT 2 48 63 0 3 10 78 7 4 07 103 3 5 34 135 7 1 59 40 3 1 35 34 2 FLOOD mm inch PRELIM INARY ...

Page 4: ...otes Warnings 5 Pre Post Dive Inspection 5 Troubleshooting 6 RMA Procedure for Repair 6 Limited Warranty 6 Appendix A LSL 1000 Driver Characteristics 7 8 Appendix B LSL 2000 Driver Characteristics 9 10 Appendix C Dimming Curve 11 13 Appendix D Beam Patterns 14 Appendix E SeaSense Information 15 PRELIM INARY ...

Page 5: ... service This light was thoroughly pressure tested prior to leaving the factory to confirm the integrity of the complete assembly While there should be no reason to repair the LED SeaLite this light is designed to be completely field serviceable No soldered wire connections or specialized tools are required All o rings use viton material and have an extended shelf life The LED SeaLite can run at f...

Page 6: ...re DeepSea Power Light Inc to furnish such new parts Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code 2715 Pre Post Dive Inspection Check to make sure that the rear bulkhead connector mating connector and all mounting hardware are secure before deployment Check the following areas for previous damage wear or corrosion r...

Page 7: ...0 180 190 200 80 100 120 140 160 180 200 Input Power W rms Input Voltage V rms LSL 1000 Real Power vs RMS Input Voltage AC DC 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 80 100 120 140 160 180 200 220 Input Current A rms Input Voltage V rms LSL 1000 Peak RMS Current vs RMS Input Voltage AC DC PRELIM INARY ...

Page 8: ...00 110 120 130 140 150 160 Power Factor Input Voltage VAC LSL 1000 Power Factor vs RMS Input Voltage 0 50 100 0 50 100 0 50 100 10 C 5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C Light Output Ambient Water Temperature LSL 1000 Thermal Operating Limits 90VAC 120VAC 140VAC PRELIM INARY ...

Page 9: ... Power W Input Voltage VDC LSL 2000 Input Power vs DC Input Voltage Low Input Range High Input Range Low Output Range High Output Range 100 50 0 0 1 2 3 4 5 6 7 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Light Output Input Current A Input Voltage VDC LSL 2000 Input Current vs DC Input Voltage Low Input Range High Input Range Low Output Range High Output Range PRELIM INARY ...

Page 10: ...Lite Operator s Manual 10 0 50 100 0 50 100 0 50 100 10 C 5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C Light Output Ambient Water Temperature LSL 2000 Thermal Operating Limits 10VDC 20VDC 48VDC PRELIM INARY ...

Page 11: ... 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Light Output LOUT Command Value SeaSense Serial Dimming Curve 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 Light Output Phase Angle LSL 1000 TRIAC Phase Dimming Curve PRELIM INARY ...

Page 12: ...0 0V 0 5V 1 0V 1 5V 2 0V 2 5V 3 0V 3 5V 4 0V 4 5V 5 0V Light Output Dimming Voltage V LSL 2000 0 5V Analog Dimming Curve 0 10 20 30 40 50 60 70 80 90 100 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Light Output Dimming Voltage V LSL 2000 0 10V Analog Dimming Curve PRELIM INARY ...

Page 13: ...D SeaLite Operator s Manual 13 0 10 20 30 40 50 60 70 80 90 100 0mA 2mA 4mA 6mA 8mA 10mA 12mA 14mA 16mA 18mA 20mA Light Output Dimming Control Current mA LSL 2000 4 20mA Analog Dimming Curve PRELIM INARY ...

Page 14: ...e Flood LSL 1000 6KA DW 075 PV SUBMC3 5680 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 100 0 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Radial Lux Distribution Comparison 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 0 25 50 75 100 Degrees Output Angular Distribution PRELIM INARY ...

Page 15: ...ay be present in the LED SeaLite The SeaSense protocol allows for an unparalleled flexibility in the use and operation of the LED SeaLite Using the protocol operators and system integrators can Control the light output level and remap the dimming curve to fit application requirements Monitor system parameters and diagnostic information such as total run time internal temperature and number of powe...