2.8 Mode Trigger: 2 Tone Mode (Vista RG1000 V2 ONLY!)
The Vista RG1000 V2 has a two position Mode trigger switch located on the bottom right side of
the control box. This Switch is only active when trigger switch on the face plate is in the Full All
Position.
2 Tone Mode
- Low tone for ferrous objects and High tone for non-ferrous objects.
In the 2 Tone Mode, all non-ferrous and ferrous targets which are accepted according to the Disc.
knob setting (to the right of the Disc. setting), will give a high tone. All targets rejected by the
Disc. knob setting (to the left of the Disc. setting) will give a low tone. You can adjust the size of
ferrous target to be accepted by either turning the Disc. knob to the left (the smaller the size of the
ferrous target in order to give a low tone) or by turning the Disc. knob to the right (the bigger the
size of the ferrous target in order to give a high tone). Big ferrous targets will still give a high tone
but are easily identified by the strong signal along with a slight low iron tone at the end of the
target.
This Mode is highly effective in iron patches to clearly identify non-ferrous targets among ferrous
targets and also to specifically search for certain ferrous targets.
-
Remember, the Vista RG1000 V2 must be properly ground balanced for optimum
performance.
12
TWO TRIGGER SWITCH
FORWARD POSITION
(Trigger pushed furthest from you.)
2-TONE MODE