15.  FIVE-YEAR LIMITED WARRANTY

 

 
The  Defender  commercial  carbon  monoxide  detectors  are  manufactured  in  Canada 
under  stringent  ISO  9001  quality  management  practices.    The  manufacturer  warrants 
that, for a period of five years from the date of purchase, this carbon monoxide detector 
will  be  free  from  defects  in  material  and  workmanship,  and  the  factory  sealed  lithium 
batteries will power the CO detector for five years.  The manufacturer, at its option, will 
repair  or  replace  this  product  or  any  component  of  the  product  found  to  be  defective 
during the warranty period.  Replacement will be made with a new or re-manufactured 
product or component. 

If the product is no longer available, replacement may be made with a similar product of 
equal or greater value.  This warranty is valid for the original end-user purchaser from 
the  date  of  initial  purchase  from  an  authorized  distributor,  dealer  or  contractor,  and  is 
not  transferable.    Keep  the  original  sales  receipt.    Proof  of  purchase  is  required  to 
obtain warranty service.  Distributors, dealers or contractors selling Defender products 
do not have the right to alter, modify or in any way change the terms and conditions of 
this warranty. 

This warranty does not cover normal wear of parts or damage resulting from any of the 
following: improper storage, negligent use or misuse of the product, use contrary to the 
operating instructions, operation in unconditioned space (below 40°F or above 100°F), 
disassembly,  or  repair  or  alteration  by  anyone  other  than  the  manufacturer  or  an 
authorized  service  center.    Further,  the  warranty  does not  cover  acts  of  God,  such  as 
fire, flood, earthquakes, hurricanes and tornadoes. 

The  manufacturer  shall  not  be  liable  for  any  incidental  or  consequential  damages 
caused  by  the  breach  of  any  express  or  implied  warranty.    Except  to  the  extent 
prohibited  by  applicable  law,  any  implied  warranty  of  merchantability  or  fitness  for  a 
particular  purpose  is  limited  in  duration  to  the  duration  of  the  above  warranty.    Some 
states  or  jurisdictions  do  not  allow  the  exclusion  or  limitation  of  incidental  or 
consequential  damages  or  limitations  on  how  long  an  implied  warranty  lasts,  so  the 
above  limitations  or  exclusion  may  not  apply  to  you.    This  warranty  gives  you  specific 
legal rights, and you may also have other rights that vary from state to state. 

Warranty Service: 

If  service  is  required,  do  not  return  the  product  to  your  supplier.    Contact  our  U.S. 
manufacturer’s representative at (800) 253-1529, Monday through Thursday, from 7 AM 
to 4 PM PST to obtain a Return Authorization (RA) number.  To assist in serving you, 
please  have  the  model  number,  date  of  purchase,  and  manufacturing  date  available 
when calling. 

Prior  to  returning,  deactivate  the  detector  per  the  instructions  in  Section  13,  pack 
carefully in a padded container, and ship freight prepaid with your original sales receipt, 
an explanation of the problem, and your return address. 

 
 

 

 Defender Detectors 

P.O. Box 60177

 

Reno, NV 89506

 

(800) 253-1529 

www.defenderdetectors.com

 

Summary of Contents for CD8110

Page 1: ...d Commercial CO Detector Single Station CD8180 Sealed Lithium Battery Powered Commercial CO Detector with LCD Digital Display and Peak Level Memory Single Station DISPLAY CO LEVEL TEST RESET MUTE Commercial CO Detector ALARM POWER SERVICE TM DEFENDER PPM Manual P N EOMN0 110 8110 Rev 01 Nov 27 2017 Copyright 2017 Defender Detectors ...

Page 2: ... THIS DETECTOR WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR CARBON MONOXIDE GAS MAY BE PRESENT IN OTHER AREAS THIS DETECTOR IS DESIGNED TO DETECT CARBON MONOXIDE GAS FROM ANY SOURCE OF COMBUSTION IT IS NOT DESIGNED TO DETECT SMOKE FIRE OR ANY OTHER GAS THIS DETECTOR IS DESIGNED TO HELP PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY ...

Page 3: ...LLER ON OR NEAR THE DETECTOR Certain kinds of aerosol chemicals will damage the sensor and cause improper operation The building must be well ventilated when using cleaning supplies or similar contaminants 2 WARNING MESSAGES WARNING This CO detector is designed to measure compliance with the U S Occupational Safety and Health Administration OSHA workplace exposure limits and does not comply with A...

Page 4: ...d Optional Display Buttons Audible and Visual Alarm Signals Separate Alarm Power and Service LED s Self Diagnostic Circuitry and Sensor Life Monitor Secure Lock Mounting System Complies with OSHA Permissible Exposure Limit PEL Complies with UL 2034 Sensitivity Limits UL Tested and Listed to Latest ANSI UL 2075 Standard Five Year Limited Warranty for Detector and Batteries Power LED TEST RESET MUTE...

Page 5: ...ithin last minute from 9 999 ppm Peak Level Memory manually displays highest CO level detected within last 30 days from 9 999 ppm Peak Level Time Record manually displays total time the highest CO level was detected within 10 of the peak from 1 999 minutes Display Tolerance 20 from 30 to 400 PPM 50 RH 72 5 F Electrochemical Sensor Defender s CO detectors are programmed to accommodate sensor tolera...

Page 6: ...tion rises people become nauseous unconscious and ultimately die see below WHAT ARE THE SYMPTOMS OF CARBON MONOXIDE POISONING Many people often confuse carbon monoxide poisoning with the flu the initial symptoms being very similar Different concentrations of CO over various lengths of time cause different symptoms The following symptoms may be related to CARBON MONOXIDE POISONING and should be dis...

Page 7: ...should be installed inside or near every sleeping area or room according to the manufacturer s instructions 6 LOCATIONS TO AVOID NEAR A COOKING AREA Do not install the detector within five feet of any cooking appliances CO may be generated in the cooking process and cause nuisance alarms Also cooking grease can build up on the detector and cause detector failure Any detector that is installed near...

Page 8: ...ically activated 4 It is important that you use the mounting plate provided If the mounting plate is not used you must slide the activation switch at the back of detector to the left until it meets the Stop or ON position as in diagram B 5 Once activated the CO detector should operate for five years without battery replacement The POWER green LED will flash once every 60 seconds and model CD8180 L...

Page 9: ...RATION The CO detector is operational once the activation switch is slid to ON position and a one minute warm up is complete The POWER green LED will flash once every 60 seconds and model CD8180 LCD continuously display LOW BATTERY CONDITION When the battery voltage drops below an acceptable level the detector will chirp once per minute and the POWER green LED will blink 5 seconds every minute The...

Page 10: ...atically reset See Section 10 WHAT TO DO WHEN THE ALARM SOUNDS TEST RESET MUTE BUTTON The TEST RESET MUTE button is used to check the detector for proper operation and to temporarily mute horn for 5 minutes when alarm is activated for 24 hrs during the first week of a Low Battery Voltage signal activation or for 60 hrs during the first month of an End of Life signal activation The model CD8180 LCD...

Page 11: ... of CO gas is injected for about 5 to 6 seconds If too much CO gas is injected the detector will trigger the trouble signal 2 short beeps SERVICE red LED blinks for 5 seconds and CD8180 LCD displays Remove the enclosure from the CO detector and purge the CO with fresh air for a few minutes until the detector returns to normal POWER green LED flashes once every minute and CD8180 LCD displays then r...

Page 12: ...ble signal is not sounding To mute the audible signal during an End of Life condition press the TEST RESET MUTE button The SERVICE red LED will glow for 5 seconds the model CD8180 will display at the same time and the horn will be temporarily silenced for 60 hours When the audible signal reactivates you can continue to mute the horn for an additional 60 hour period by again pressing the TEST RESET...

Page 13: ... You can temporarily silence an audible alarm signal by pressing the TEST RESET MUTE button The ALARM red LED will flash 4 times and the model CD8180 will display for 5 seconds and then continue to display the current CO level detected from 30 to 999 ppm If 50 ppm or more continues to be detected the audible and visual alarm signals will be automatically reactivated within 5 minutes Do not wait to...

Page 14: ... of the presence of CO gas at a reasonable cost However detectors have sensing limitations and may not always sound a warning in the presence of CO The detector will not operate if the battery power is low or dead CO detectors must be tested regularly to ensure that they are receiving power and operating properly Carbon monoxide detectors cannot sense CO that does not reach the detector and theref...

Page 15: ...l has been activated See below procedures to remove and deactivate the detector and discharge the batteries The detector can be disposed of using the same method for disposing of discharged lithium batteries Should the low battery voltage signal occur in less than five years after initial activation the battery power capacity may be low because of long term storage prior to installation exposure t...

Page 16: ... screw driver into the slot to pry out the deactivation STOP Slide the switch to the farthest left end to deactivate the detector The switch moves in one direction only and cannot be moved back Once the detector is deactivated the sealed lithium batteries will be fully discharged and the detector will no longer work E495778 Mounting hole is closed when switch is slid to Deactivate Detector is perm...

Page 17: ...ected and duration of peak CO level Each readout lasts 5 seconds POWER green LED blinks once when CO level display readout is completed Silent Clear Peak Memory Displays POWER green LED blinks once when clear peak memory is completed Bursts a long beep Low battery voltage Displays symbol POWER green LED blinks for 5 seconds every minute Chirps once per minute Mute low battery voltage audible signa...

Page 18: ...in unconditioned space below 40 F or above 100 F disassembly or repair or alteration by anyone other than the manufacturer or an authorized service center Further the warranty does not cover acts of God such as fire flood earthquakes hurricanes and tornadoes The manufacturer shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty Exce...

Reviews: