background image

 

14 

General warranty terms and conditions 

When following the instructions for installation, operation and maintenance, the manufacturer guarantee 24 months from 

the date of receipt for the product

. Should the product purchased be put into operation by an entity other than the seller, the 

warranty period commences from the date that the product is put into operation, provided that the buyer ordered its 

commissioning within three weeks of its receipt. The customer expressly acknowledges that during the warranty period that 

extends beyond the length of the warranty period that is specified in the Commercial Code (the statutory warranty) s/he can 

neither require replacement of the product nor may s/he withdraw from the contract. 

 

1.

 

When claiming a product defect it is necessary to submit a proof of purchase that contains the following information: 

name and surname, name and business name, address and the warranty card, if the buyer received one from the seller. 

The validity of the warranty shall not be affected by non-compliance with the obligations related to the issuance of the 

warranty card. 

2.

 

Claims concerning the product (for a warranty repair only complete devices are accepted) may be filed during the 

warranty period only  with the  seller from which it was purchased;  subsequently the seller is required to forward the 

product to an authorised service centre or to the manufacturer.  

3.

 

A condition for the recognition of the rights under the warranty is the installation of the product having been undertaken 

by an authorised person in possession of a valid certificate from the manufacturer. 

5.

 

Claims regarding a product defect that can be dealt with reasonably quickly and without additional consequences will be 

resolved by remedying the  defect  (repair) or by replacement of  the product part  , because in such a case it is a 

contradiction of the standard norms that the entire product shall be replaced (§ 616, paragraph 4 of the Commercial 

Code). 

6.

 

The buyer who exercises the right of warranty repair is not entitled to the return of the parts that have been replaced.  

7.

 

The warranty period can be extended for up to 48 months and its validity can be extended beyond the standard length on 

the basis of the conclusion of an individual warranty contract. Further information may be obtained through a specific 

business meeting. 

 

This warranty is not applicable to: 

 

a product that has not 

been put into operation by the manufacturer or by a certified employee

 in possession of a valid 

certificate issued by the manufacturer 

 

A product that did not have regulary performed calibrations and functional checks by the manufacturer or by a certified 

employee is possession of a valid certificate issued by the manufacturer. 

 

damage caused by fire, water, static electricity, power surges in the electric supply or in the public network, accident, 

improper use of the product, wear and tear 

 

contamination of the product and its subsequent cleaning 

 

damage caused by 

improper installation, any adjustment, modification

 or improper manner of use inconsistent with the 

instruction manual, the technical standards or the applicable safety regulations in the Czech Republic 

 

damage to the product during transportation caused by improper handling or handling of the  product in a manner 

contrary to the advice provided in the instruction manual 

 

DEGA products that have 

been used in association with other than original DEGA products

, including consumables and 

accessories

 

 

bearing additional parts or consumables (e.g. a foil label, seal, etc.), that are detrimental to normal wear and tear during 

operation, together with wear and tear of the product and its parts caused by their normal use

 

 

For the complete version of the general business conditions and of the claims procedure go to www.dega.cz  

 

Manufacturer: DEGA CZ s.r.o., Malešická 2850/22c, 130 00 Praha 3, Czech republic 
VAT: CZ 279 029 43, Telephone  +420 774 447 660 E-mail: info@dega.cz , Web: www.dega.cz 

 

 

© 2015 DEGA CZ s.r.o.   

User Manual ver.: 05.08.2020 15:14:00 

 

Summary of Contents for NS III LCD

Page 1: ...any form without the prior permission of DEGA CZ s r o is prohibited DEGA CZ s r o reserves the right to alter the specifications of the hardware and software described in this manual at any time and without prior notice DEGA CZ s r o bears no liable for any damage resulting from use of this device ...

Page 2: ...tter 8 2 Gas detection 8 3 Malfunction 8 4 Monitoring the calibration periods 8 5 Reading the record of measured concentrations and alarms 8 Operation maintenance inspection and service of the transmitter 8 1 Usage limits 8 2 Operation 9 3 Operation Maintenance 9 Accessories and basic types of transmitters 9 1 Calibration adapter connection to the gas pump DEGA GAS INLET 9 2 Cover against splashin...

Page 3: ...tter sensors with respect to the environment Transmitter sensors contain hazardous substances Dispose of them in accordance with the current legislation on environmental protection Use the transmitter only with the appropriate certified DEGA products The device is certified as functionally and technically qualified only with original DEGA accessories In case of using the device with any other prod...

Page 4: ...LCD RE max 30 min DEGA NSx SL III DEGA NSx PL III PID 90 mA 2 2 W 154 mA 3 7 W DEGA NSx SL II LCD RE DEGA NSx PL III PID max 5 h max 30 min Response time T90 Sensor lifetime in a clean environment DEGA NSx EL II LCD RE max 180 s based on sensor type DEGA NSx EL II LCD RE 2 years DEGA NSx CL II LCD RE max 15 s DEGA NSx CL II LCD RE 2 years DEGA NSx IL II LCD RE max 15 s DEGA NSx IL II LCD RE 5 year...

Page 5: ...atalyst poisons sulfur and silicon compounds which cause a change of sensitivity of catalytic sensors The sensors are characterized by high stability and a long lifetime DEGA NSx SL III with a semiconductor sensor Cheapest method of scanning They operate on the principle of changes in electrical conductivity of semiconductors by changing the concentration of the detected gas Their advatage is a lo...

Page 6: ...smitter with the four hexagon socket screws 4mm b Disconnect the LCD motherboards c Mount the transmitter on a flat surface with four 6mm fasteners in height above the floor with the gas entrance facing downwards as specified by the detected substance d Direct the cable trough the bushing e Connect the cabeling to the terminal block When using the second Ex d bushing dismout the Ex d blind plug It...

Page 7: ... of cable depends on the fire report and the protocol for determining external influences 7 Setting the RS485 adress of the transmitter Each transmitter must have a unique adress within the entire bus otherwise there will be communication collisions and malfunctions The transmitter adress can either be set internally using the DegaConfig program or using the DIP switch on the PCB If the position 6...

Page 8: ...alue to the evaluation unit via DEGA MOBUS protocol 3 Malfunction If a malfunction of electronics or the sensor is detected during operation the transmitters starts transmitting via a 0 5mA current loop On the PCB this state is indicated by the yellow LED ERR 4 Monitoring the calibration periods The transmitter continuously checks the calibration validity of the connected sensor After 12 months si...

Page 9: ... is set can cause an alarm even if the concentration of the gas does not exceed the set level Given the range of disturbing gases or vapors diluents exhaust gases vapors of organic substances disinfectants etc a generally allowable concentration of interfering gases can not be determined Data on cross sensitivity to certail gases are included at the apporpriate sensors Therefore before processing ...

Page 10: ...ording to the selectivity of the sensor 2 Transmitters with an electrochemical sensor NSx EL III Product code Transmitter type Detected gas Measurement range Measurement of current loop 4 20mA Resolution Calibration gas 40100022 DEGA NSCO EL 1000 III Carbon Monoxide CO 0 1000 ppm 0 130 ppm 1 ppm Carbon Monoxide 130 ppm 40100019 DEGA NSCO EL 200 III Carbon Monoxide CO 0 200 ppm 0 200 ppm 0 1 ppm Ca...

Page 11: ...de 20 ppm 40100049 DEGA NSNO2 EL 100 III Nitrogen dioxide NO2 0 100 ppm 0 100 ppm 0 1 ppm Nitrogen dioxide 20 ppm 40100050 DEGA NSNO2 EL 500 III Nitrogen dioxide NO2 0 500 ppm 0 500 ppm 1 ppm Nitrogen dioxide 100 ppm 40100046 DEGA NSNO EL 250 III Nitric oxide NO 0 250 ppm 0 15 ppm 0 1 ppm Nitric oxide 150 ppm 40100045 DEGA NSNO EL 25 III Nitric oxide NO 0 25 ppm 0 25 ppm 0 1 ppm Nitric oxide 15 pp...

Page 12: ...de 250 ppm 40100033 DEGA NSHBr EL 20 III Hydrogen bromide HBr 0 20 ppm 0 20 ppm 0 01 ppm Hydrogen sulfide 25 ppm 40100034 DEGA NSHBr EL 200 III Hydrogen bromide HBr 0 200 ppm 0 200 ppm 0 1 ppm Hydrogen sulfide 250 ppm 40100038 DEGA NSHF EL 10 III Hydrogen fluoride HF 0 10 ppm 0 10 ppm 0 01 ppm Nitrogen dioxide 20ppm 40100067 DEGA NSVOC EL 20 III VOC 0 20 ppm 0 20 ppm 0 01 ppm VOC 20ppm 40100003 DE...

Page 13: ...4000 ppm 0 500 ppm 0 1ppm Izobutylene 300ppm LEL Lowest explosion level ALARM PEL Permitted exposure limit maximal permitted value of the avarage concentration over time Alarm settings can be chosen freely according to customer requirements in measurement range Attachments 1 Chart for setting the transmitter adress adress 1 2 3 4 5 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF 3 ON ON OFF OFF OFF 4 OF...

Page 14: ...ct shall be replaced 616 paragraph 4 of the Commercial Code 6 The buyer who exercises the right of warranty repair is not entitled to the return of the parts that have been replaced 7 The warranty period can be extended for up to 48 months and its validity can be extended beyond the standard length on the basis of the conclusion of an individual warranty contract Further information may be obtaine...

Reviews: