2.
Assemble the supporting struts with four M16x80 bolts,
eight washers, and four nuts, on the side facing the flange
side of the central pipe. The bolt connections only need to
be tightened by hand.
3.
Ensure a distance of 1275 mm between the inner areas of
the base plates. Then tighten the bolts.
Check: the distance between the central hole of the bearing
bracket and the ground must be 1.55 m.
Tightening torque: 200 Nm
4.
Push the outer supporting struts, with the bearing bracket
ahead, to the outer hinge pins of the central pipes. Fit an
M20 washer behind each one.
5.
Insert the splint into the hinge pin hole and bend up as
shown to secure both ends.
15
50
mm
1275 mm