23.09.2015
ASSEMBLY AND OPERATING MANUAL DEGERtracker S60H CF
Page 28
6.8.2
Clamping to the end of the module area (all modules)
Tightening torque: 10 Nm
ATTENTION!
As described under 6.8.1, the notch in the front of the hammer head bolt must be perpendicular
to the groove in the aluminum profile.
6.9
MLD sensors assembly
2. Install the MLD sensor centrally on the north side of the solar module surface. In countries of the
southern hemisphere the MLD sensor must be installed on the south side of the solar module surface.
Tighten together the mounting bracket of the MLD sensor and the aluminum profile with the M10 square
head bolt, washer and nut. Align MLD sensors with a 90°angle to the module edge as shown in the
diagram.
Tightening torque: 40 Nm
End clamp
M6 Hammerhead bolt
North
Northern
hemisphere
South
southern
hemisphere