If you forget your programming code, you can reset the lock by the following steps:

Initialize by removing battery: Remove one battery (any one of the four batteries) , keep 

pressing the black color privacy lock out mode button under the knob at the back panel 

and do not loose your hand, then put the removed one battery back, and wait until you 

hear 4 "Beep" sound, then the lock has been reset successfully (the "privacy lock out 

mode button kept pressing" operation must maintain after you put the removed one 

battery back, this period will take about 10 seconds).

To return the door lock to the factory default values and codes, choose one of the follow-

ing methods:

4. RESET

4.1. Virtual reset

Enter the

programming code

Enter the

programming code

3.6. Cancel automatic closing

1

2

3

4

5

6

7

8

C

0

9

Note:You can cancel 
any of the processes by 
pressing the 

c

 key.

Note: After resetting, all codes will be deleted 
and the lock will revert to factory default state, 
of which the lock programming code will be 
back to 123456 and user code be back to 123.

1

2

3

4

5

6

7

8

9

0

C

1

2

3

4

5

6

7

8

9

C

0

4.2. Physical reset

Press the RESET button  on back panel 

09

Enter the

programming code

Press the “9” key

Press the “0” key

Summary of Contents for DKEB01-SS

Page 1: ...USER MANUAL USER MANUAL Thank you for purchasing our products Please read this instruction carefully before use and strictly follow the instructions 1 2 3 4 5 6 7 8 9 C 0 ...

Page 2: ...tion Door frame 110mm Door thickness 38 48mm Left open Right open Door Preparation Packing List 01 A 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 2 Piece G H I J K L B C D E F 25mm 4 Piece 40mm 1 Piece 30mm 3 Piece 22mm 1 Piece 10mm 2 Piece 6 8mm 5 8mm 6 0mm 5 4mm 1 0mm 25mm 2 7mm ...

Page 3: ...on Diagram Installation Instructions L K J A B I C D E G H F A Check the required backset 60mm or 70mm B Align the template along the vertical center line of the deadbolt D at the desired height and tape it to the door C Mark the holes first then start drilling 02 ...

Page 4: ...he door B G A F Note Cable goes underneath deadbolt Note The cable goes through the notch on the lower right part of the mounting plate at first E D Note The deadbolt has TWO backset options 60mm or 70mm please adjust it by yourself Note DO NOT Push the latch out before installation Before inserting the latch into the hole check that the mark is facing upwards 03 ...

Page 5: ...using mechanical key J C I H 1 2 3 4 5 6 7 8 9 C 0 E 5 8mm 25mm 2 7mm K L 04 Note Put the lock spindle VERTICALLY into the hole connected to the knob at the indoor unit of the lock that means the rotating part of the knob should also be turned to VERTICAL position L R If it is a left hand door please turn the switch to L If it is a right hand door please turn the switch to R ...

Page 6: ... lower than 4 8V the lock beeps and LED flash es red for 5 seconds Replace all four batteries with new ones immediately 7 Do not use or store the product in places where there are leaks or splashes 8 Do not use solvents or other corrosive chemicals to clean the exterior of the system 9 This device is not intended for use by persons including children whose physical sensory or mental abilities are d...

Page 7: ... to attempt the pin again Mechanical key can be used to unlock in this state All specifications are subject to change without notice All rights reserved Specifications Material Door thickness Woring Temperature Working Power Consumtion Power Supply Unlocking Methods User Capacity Zinc Alloy 38mm 48mm 20 C 70 C 200mA 6V 4pcs AA Alkaline Batteries not included Passcode Mechanical Key 10 code users Fro...

Page 8: ...er the knob of back panel which is a privacy lock out mode which essentially is a do not disturb mode this will make the lock no longer accept pin codes except for mechanical key Note Once the programming has started if you do not press any key for 20 seconds the process will be canceled 2 LOCK 1 2 3 4 5 6 7 8 9 C 0 Press the lock key and it will automatically close the lock 3 PROGRAMMING 3 1 Crea...

Page 9: ...3 4 Change the programming code Enter the new programming code Enter the programming code Repeat the code 1 2 3 5 6 7 8 9 C 0 4 3 5 Activate automatic closing In a range of 10 to 999 seconds enter the delay time for the door lock automatically close 1 2 3 4 5 6 7 9 C 0 8 08 Enter the programming code Enter the programming code Press the 2 key Press the 3 key Press the 4 key Press the 8 key ...

Page 10: ... one battery back this period will take about 10 seconds To return the door lock to the factory default values and codes choose one of the follow ing methods 4 RESET 4 1 Virtual reset Enter the programming code Enter the programming code 3 6 Cancel automatic closing 1 2 3 4 5 6 7 8 C 0 9 Note You can cancel any of the processes by pressing the ckey Note After resetting all codes will be deleted an...

Reviews: