4.5 Alternating current installation
The yacht is equipped with a 230 V shore connection unit. When you are mooring in a
harbour, you can feed power into the on.-board system with a connection cable. The plug
(plug according to EEC standards) can be installed in the anchor locker or at the end of the
cockpit. 230 V plugs are placed in the shore connection unit in the space under the navigation
table, the shower room and the pantry.
4.5.1 Shore connection unit
•
Manufacturer CALIRA 421
•
On/off charge unit
•
FI- automatic switch
•
Net control light
•
On/off switch heat exchanger
•
with control light
•
230 V safety plug
Charging of the battery starts once the shore
connection cable gets plugged in. The three 230 V
plugs are all ready. They are only there for power
consumers.. Please think about the limited watt power
of land plugs. The outlet towards the hot water heating
in the heat exchanger has a fixed cabling, which is
separately switched and protected.
FIGURE.:
SHORE CONNECTION
SWITCH BOARD
4.5.2 Charge unit MASTERVOLT
Name Standard
Optional
Model
IVO 12/25-2
IVO 12/40-3
Voltage 230/110V
230/110V
Power
25 Amp.
40 Amp.
Charge voltage
14,25-13,25V
14,25-13,25V
Charge characteristic
IUoUo
IUoUo
HINT
Please read through the attached
safety instructions