27
Check and if necessary replace the airfilter of the air compressor according to following figure.
Time frame: quarterly
I.
Disconnect air compressor from electricity grid (power supply).
II.
Loose srews (1) and remove cover plate (4).
III.
Remove air filter (5) from chassis (6) and put a new air filter into it.
IV.
Clean air inlet at cover plate (4) and top of cover (6).
V.
Install cover plate (4) correctly at filter cover plate (6).
VI.
Install cover plate (4) at top of cover (6) by tighten the screws (1).
Heed the inspection intervals in the operating and installation guide for the pressure booster as well!
The operating hours of the air compressor is essential for the maintenance intervals. After a run time of 16,000 operating hours
(approx. 20 months of operation), the me
ssage “Maintenance” (see
operation manual GWM
8.1) is shown on the control unit
display. A contracting party or DEHOUST has to carry out the maintenance and to reset the operating hours meter.
The filtration performance of the BMT-membrane filter depends on the greywater composition, the real daily treatment perfor-
mance and the real consumption for process water. For these reasons it may happen that the BMT-membrane filter has to be
exchanged before the regular maintenance interval.
The exchange of the BMT-membrane filter has to be done by a contracting party or DEHOUST. Please heed the corresponding
manual for BMT-membrane filter exchange and software update
.
7.1.5.
Check air compressor
7.1.6.
Function of the pressure booster
7.2.
Maintenance