background image

DM-4 Gas/Hydro 

 

 

 

Application Notes, PCM TCP/IP port (WebArm)

 

 

 

DEIF A/S

  

Page 4 of 10 

 

2.  Warnings and legal information 

 

Legal information and responsibility 

DEIF takes no responsibility for installation or operation of the generator set. If there is any doubt 
about how to install or operate the generator set controlled by the unit, the company responsible 
for the installation or the operation of the set must be contacted. 
 
 
 
 
 

Electrostatic discharge awareness 

Sufficient care must be taken to protect the terminals against static discharges during the 
installation. Once the unit is installed and connected, these precautions are no longer necessary. 

Safety issues 

Installing the unit implies work with dangerous currents and voltages. Therefore, the installation 
should only be carried out by authorised personnel who understand the risks involved in working 
with live electrical equipment. 
 
 
 
 
 
 

Definitions 

Throughout this document, a number of notes and warnings will be presented. To ensure that 
these are noticed, they will be highlighted in order to separate them from the general text. 

Notes 

 
  
 
 

Warnings 

 
 
 
 
 
 

The notes provide general information which will be helpful for the reader to bear 
in mind. 

The warnings indicate a potentially dangerous situation which could result in 
death, personal injury or damaged equipment, if certain guidelines are not 
followed. 

Be aware of the hazardous live currents and voltages. Do not touch any AC 
measurement inputs as this could lead to injury or death. 

The DM-4 is not to be opened by unauthorised personnel. If opened anyway, the 

warranty will be lost. 

Summary of Contents for DELOMATIC 4 Series

Page 1: ...APPLICATION NOTES PCM TCP IP port WebArm TCP IP setup Document no 4189340652A DELOMATIC 4 DM 4 GAS HYDRO ...

Page 2: ...NDED USERS 3 CONTENTS OVERALL STRUCTURE 3 2 WARNINGS AND LEGAL INFORMATION 4 LEGAL INFORMATION AND RESPONSIBILITY 4 ELECTROSTATIC DISCHARGE AWARENESS 4 SAFETY ISSUES 4 DEFINITIONS 4 3 ABSTRACT 5 4 CONFIGURATION OF THE PCM CARD 6 CHECK SOFTWARE VIA IP CONNECTION 6 CHECK SOFTWARE WITH TELNET 7 CHANGE OF PC IP CONFIGURATION 8 DM 4 IP ADDRESS 10 ...

Page 3: ...cases this would be a panel builder designer Naturally other users might also find useful information in this document Contents overall structure The document is divided into chapters and in order to make the structure of the document simple and easy to use each chapter will begin from the top of a new page Please make sure to read this handbook before working with the DM 4 controller and the gen ...

Page 4: ...ork with dangerous currents and voltages Therefore the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment Definitions Throughout this document a number of notes and warnings will be presented To ensure that these are noticed they will be highlighted in order to separate them from the general text Notes Warning...

Page 5: ...5 of 10 3 Abstract The DM 4 offers TCP IP communication which may need to be changed address etc This document is the instruction manual that tells how to carry out changes and which changes are available Furthermore it describes how to check the PCM module WebArm module ...

Page 6: ...on Use a TCP IP cable to connect your PC to the DM 4 Ethernet port Open your internet browser Key in the IP address in the address field Click enter You now get the information screen from the PCM card Select Device Status You may be prompted for a name and password User name admin Password admin From factory the IP address is 192 168 2 21 ...

Page 7: ... The OS version will if correct display the date here Nov 15 13 556 03 GMT 2007 Alternative to using a web browser Check software with telnet Under Windows start prompt Select Run Write cmd and press enter The command prompt will appear Now start telnet Command telnet ip address example telnet 192 168 2 21 ...

Page 8: ... is the correct WebArm software exit to disconnect from PCM card The software has now been checked Change of PC IP configuration If it is not possible to establish connection the PC IP setting may have to be changed Select in windows START Settings Control panel Network connections Local area connection Properties Internet protocol TCP IP ...

Page 9: ...ot be used here Subnet mask 255 255 255 0 After this you can check the connection using ping In Windows Start Run Cmd In the prompt write ping 192 168 2 21 example use the relevant DM 4 IP address If successful the prompt looks like this Now the DEIF HMI BROWSER can be used and the user interface can be started Remember that you have to change back to original settings after finishing this check ...

Page 10: ...ddress for the DM 4 Note that the system has to be restarted before the change takes effect The default IP address is 192 168 2 21 The default netmask is 255 255 255 0 Example DEIF A S reserves the right to change any of the above When the IP address is changed only the new address can be used to access the DM 4 via TCP IP Make sure that you use a valid address if changing it ...

Reviews: