WARNINGS 

 

Failure to properly follow maintenance instructions and pre-
cautions can cause serious injuries or death.  Always follow 
the inspection and maintenance recommendations and 
schedules in this owner’s manual. 
 
Safety Precautions: 
Make sure the engine is off before you begin any maintenance 
or repairs. This will eliminate several potential hazards: 

 

Carbon monoxide poisoning from engine exhaust. 

Be sure there is adequate ventilation whenever you 
operate the engine. 

 

Burns from hot parts. 

Let the engine and exhaust system cool before touch-
ing. 

 

Injury from moving parts. 

Do not run the engine unless instructed to do so. 

 
In the State of California a spark arrestor is required by law.  
Other states may have similar laws.  Federal laws apply on all 
federal lands.  If you equip the muffler with a spark arrestor, it 
must be maintained in effective working order.  See page 12. 
 
Rapid retraction of the recoil starter cord can pull the starter 
cord back faster than you can let go.  When starting the en-
gine, pull the cord slowly until resistance is felt then pull rap-
idly to avoid kickback

.   

AC Applications 
Before connecting an appliance or power cord to the genera-
tor: 
1.  Make sure that appliances are in good working order. 

Faulty appliances or power cords can create a potential for 
electrical shock. If an appliance begins to operate abnor-
mally, becomes sluggish or stops suddenly, turn it off im-
mediately.  

2.  Disconnect the appliance, and determine whether the 

problem is the appliance, or if the rated load capacity of 
the generator has been exceeded.  

3.  Make sure that the electrical rating of the tool or appli-

ance does not exceed that of the generator. Never exceed 
the maximum power rating of the generator. Power levels 
between rated and maximum may be used for no more 
than 30 minutes. 

 
Substantial overloading will open the circuit breaker. Exceed-
ing the time limit for maximum power operation or slightly 
overloading the generator may not switch the circuit breaker 
or circuit protector OFF, but will shorten the service life of the 
generator. 
 
Limit operation requiring maximum power to 30 minutes.  For 
continuous operation (longer than 30 minutes), do not exceed 
80% of the rated power balanced equally on the A&B sides of 

Changing the speed of the generator by adjusting the governor can cause damage to the generator, 
devices attached to the generator, and may result in bodily injury.  Do not adjust or tamper with 
the engine speed setting. 

Product Specifications 

DANGER 

WARNING 

Generator 

G5000D 

G8000D 

Rated frequency 

60 Hz 

60 Hz 

Rated voltage 

120V / 240V  

120V / 240V 

Max continuous  output power 

5.0 kW (Max.) 

8.0 kW (Max) 

AC output (Max.) 

20.8A 

33.3A 

Engine type 

OHV 4-Stroke 

OHV 4-Stroke 

displacement 

270 cc 

420 cc 

Compression ratio 

8.2:1 

8.0:1 

Rated rotation speed 

3600 RPM 

3600 RPM 

Rated power 

10 Hp 

15 Hp 

Starting system 

Recoil 

Recoil and electric starter 

Rotation direction 

Counter clockwise 

Counter clockwise 

Fuel type 

Unleaded gasoline 

Unleaded gasoline 

Low oil shutdown 

Yes 

Yes 

Fuel tank size 

12 gallons 

12 gallons 

Oil type / Capacity 

SAE 10W-30 0.9 quarts 

SAE 10W-30 1.1 quarts 

Gross weight 

207 lbs (94 kg) 

235lbs (107kg) 

Battery 

N/A 

12 AH 12 VDC  

Integrated voltmeter 

Yes 

Yes 

DANGER 

Summary of Contents for G5000D

Page 1: ...6 7 Component Identification 8 Wheel Kit Installation Battery Commissioning 9 Controls 10 11 Operating the Generator 12 Maintenance 13 Maintenance Transporting and Storage 14 15 Troubleshooting 16 War...

Page 2: ...EAST Brush Mas Chipper Shredder with 2 Way Feed 100 inch Tow Behind Mower The 36 inch Brush Mower Brush 36 inch 45 inch Snow Blower Snow Beast 54 inch 62 inch Zero Turn Mower Z Beast Check out our oth...

Page 3: ...stem the generator must be installed by a qualified electrician and connected to transfer equipment as a separately derived system in accordance with the National Electrical Code NFPA 70 The generator...

Page 4: ...E HOME OR IN PARTLY ENCLOSED AREAS SUCH AS GAR AGES AND USE ONLY OUTSIDE AND FAR FROM OPEN WINDOWS DOORS AND VENTS IV THERE IS A PERMANENT CONDUCTOR BETWEEN THE GENERATOR STATOR WINDING AND THE FRAME...

Page 5: ...ddenly turn it off im mediately 2 Disconnect the appliance and determine whether the problem is the appliance or if the rated load capacity of the generator has been exceeded 3 Make sure that the elec...

Page 6: ...start option only L14 30 240V 120V Twist Lock Connector Recoil Starter Assembly Air Filter Choke Lever Ground Lug Valve Cover Muffler Guard Alternator Exhaust Pipe Generator models may have different...

Page 7: ...equipment required to safely operate this generator 1 Gas can 2 Unleaded gasoline 3 SAE 10W 30 1 1 quarts for DEK 11hp 13hp 14hp and 15hp engines 0 9 quarts required for DEK 10 HP 4 An oil fill funne...

Page 8: ...ve the battery is missing FOR YOUR SAFETY AND CONVENIENCE THE BATTERY WAS SHIPPED SEALED AND PRE CHARGED The battery is ready to be connected to the generator Approximate assembly time is 5 minutes Su...

Page 9: ...thout engine oil DO NOT START THE ENGINE WITHOUT FILLING THE ENGINE WITH OIL Use SAE 10W 30 for normal conditions and SAE 5W 30 when the ambient tempera ture is below 32 F Engine Switch To start and s...

Page 10: ...NEVER use a generator inside homes garages crawlspaces or other partly enclosed areas Deadly levels of carbon mon oxide can build up in these areas Using a fan or opening win dows and doors does NOT...

Page 11: ...in the following chart To determine maximum load that you may safely connect to this generator 1 Calculate the maximum continuous power required by adding up the running power of each appliance The t...

Page 12: ...hrs or 6 months 300 hrs or 1 year Engine oil Check X Engine Oil Change X Air Cleaner Check X Air Cleaner Wash X Fuel filter Cup Clean X Spark Plug Clean X Spark Plug Change X Optional Spark Arrestor...

Page 13: ...park arrestor in the reverse order of removal Maintenance TRANSPORTING When transporting the generator turn the engine switch and the fuel valve OFF Keep the generator level to prevent fuel spillage F...

Page 14: ...n filter and carburetor float bowl Fill tank with clean fuel Spark plug boot off loose Press spark plug boot firmly on spark plug Spark plug fouled or failed Remove spark plug clean or replace Carbure...

Page 15: ...Inspect gas ket for damage and replace if damaged Loose crankcase bolt s Tighten crankcase bolts Valve cover bolt loose Tighten bolt Oil leaking from shaft Oil seals failed call customer help line Fue...

Page 16: ...equipment on which the accessory or replacement part is installed and proof of purchase at your expense to any DEK Power Equipment service location in the United States who is authorized to service th...