Material Safety Data Sheet

Cont. 

Product Name

AQUEOUS OZONE SOLUTION 

IV HEALTH HAZARD DATA 

Threshold Limit Value        NOT DETERMINED 

Route of Exposure               Inhalation        Ingestion

 Skin         Eye        Not Hazardous 

Eye Contact Hazard 

Exposure may cause mild eye irritation, but is not expected. 

Ingestion Hazard 

Not Hazardous 

Inhalation Hazard 

Inhalation is not likely to be a primary route of exposure but could become irritating if 

aerosols are exposed to individual for extended period of time. 

Skin Contact Hazard 

No skin irritation is expected from short term exposure. 

Skin Absorption Hazard 

No published data indicates this product is absorbed through the skin. 

Effects of Acute 

Exposure 

Mild skin or eye irritation. 

Effects of Chronic 

Exposure 

Repeated exposure of the skin to concentrated product should be avoided to prevent 

irritation and drying of the skin. 

V EMERGENCY AND FIRST AID PROCEDURES 

Eye Contact 

If exposure to water containing aqueous solution of ozone causes irritation to eyes, flush eyes with 

plenty of clean, ozone free, running water for at least 15 minutes, lifting the upper and lower lids 

occasionally.  Remove contact lenses if worn.  Seek medical attention if irritation persists. 

Skin Contact 

Not likely to become irritated unless repeatedly exposed to large volumes of material.  If irritation 

develops, rinse affected area with ozone free potable water.  If irritation continues seek medical 

advice. 

Inhalation

Inhalation of mists could lead to irritation of lungs.  If symptoms develop, move individual away from 

exposure and into fresh air.  If symptoms persist, seek medical attention. 

Ingestion 

NA

VI REACTIVITY DATA 

Incompatibility 

(Materials to Avoid) 

Natural rubber (may degrade, or “dry”, rubber components over extended periods of exposure) 

Conditions 

to Avoid 

NONE KNOWN 

Hazardous 

Decomposition 

NONE

Stability           STABLE       UNSTABLE    Hazardous Polymerization        MAY OCCUR        WILL NOT OCCUR 

Summary of Contents for MPI-300

Page 1: ...Installation Operations Manual 3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com 4 0700 Rev E MPI 300 Multi Point Intervention Ozone Sanitation System...

Page 2: ...orth in the owner s manual ANTIMICROBIAL CLAIMS This device has been determined acceptable for use as an ozone generating device providing sanitization and disinfection of hard inanimate pre cleaned s...

Page 3: ...3D Standard Operating Procedures 3 SECTION 4 Maintenance Service 4A PM Schedule 4 4B Trouble Shooting 4 SECTION 5 Replacement Parts 5A Ordering Information 4 5B Standard Replacement Parts List 4 SECTI...

Page 4: ...M min Weights Dimensions 25 5 H x 24 5 W x11 D 100 lbs Ambient Temp 40 F 90 F not to exceed 90 F 1C Layout Accessories The MPI 300 is a low pressure ozone enriched cold water surface sanitizer Interna...

Page 5: ...ed to a location close to your process This can be a level location either indoors or outdoors For all systems allow for access to protected electrical power and required water connections The point o...

Page 6: ...inal sanitizing rinse leaving no residual 3D 1 Surface Sanitation The spray can be directed on all wettable wood metal concrete and plastic surfaces including floors drains walls conveyors containers...

Page 7: ...numerical reading SECTION 4 MAINTENANCE AND SERVICE 4A Preventative Maintenance Schedule DAILY 1 Check ozone generator for proper operation Make sure green indicator lights are lit during operation MO...

Page 8: ...0 1 0 2 770 3740 0 2 6 7 1 1 2 5 Rotavirus 0 006 0 06 3810 6480 0 2 2 1 0 01 0 05 G lamblia cysts 0 5 0 6 47 150 G muris cysts 1 8 2 0 1400 7 2 18 5 30 630 6A 2 Materials Selection Materials Aqueous O...

Page 9: ...one to which workers may be exposed averaged over 8 hours 5 days a week OSHA Gaseous ozone concentrations above 0 02 PPM are detectable by humans Inasmuch sections 6C through 6H of this manual discuss...

Page 10: ...ure times ranging from 5 minutes to 10 hours 6D 2 Ventilation It is mandatory that general and local exhaust ventilation be provided to dilute and disperse small amounts of ozone into the outside atmo...

Page 11: ...34 may be used for personnel or area monitoring for exposure times ranging from 5 minutes to 10 hours For higher resolution the ChromAir ozone badge may be used in conjunction with the ChromAir ozone...

Page 12: ...ng has ceased start artificial respiration rescue breathing is the most effective method until breathing has been restored 2 Send for medical assistance immediately 3 If absent begin cardiopulmonary r...

Page 13: ...10 MPI 300 Installation Operations Manual APPENDIX A DAILY DATA LOG...

Page 14: ...11 MPI 300 Installation Operations Manual APPENDIX A...

Page 15: ...12 MPI 300 Installation Operations Manual APPENDIX B EMERGENCY INFORMATION...

Page 16: ...13 MPI 300 Installation Operations Manual...

Page 17: ...14 MPI 300 Installation Operations Manual APPENDIX C SAFETY...

Page 18: ...pping Classification NON REGULATED I PHYSICAL DATA Boiling Point 212 F Freezing Point 32 F Specific Gravity 1 0 Solubility in Water COMPLETE Evaporation Rate APPROX 1 Physical Form LIQUID Appearance O...

Page 19: ...prevent irritation and drying of the skin V EMERGENCY AND FIRST AID PROCEDURES Eye Contact If exposure to water containing aqueous solution of ozone causes irritation to eyes flush eyes with plenty of...

Page 20: ...e periodic exposure levels established by OSHA for worker safety through the use of DEL s ozone management technology Precautions To Be Taken In Handling Aqueous solutions of ozone in potable water sh...

Page 21: ...E WARRANTED ONLY FOR THE BALANCE OF THE ORIGINAL TWO 2 YEAR WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT AND MAINTENANCE PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WA...

Page 22: ...3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001...

Reviews: