background image

MPI-300 

Installation & Operations Manual

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS.

Read this manual completely before operation of AGW–0500 Ozone Generator Equipment. The High Voltage 
Transformers in this unit create 7,000 volts, with the outer jacket of the High Voltage lead reaching 3,000 volts. 
 

- USE EXTREME CAUTION -

Operate the AGW–0500 on a near level surface with safe access to electrical power. 
Connect to a G.F.C.I. type receptacle.  
Follow all applicable electrical codes. 
Do not bury cord. 
WARNING: To reduce the risk of electrical shock, replace damaged cord immediately. 
ELECTRICAL SHOCK HAZARD: Turn OFF all power switches and disconnect power cord from power source receptacle 
before performing any service work. Failure to do so could result in serious injury or death.

SAFETY CLAIMS

Performance safety testing was based on the 

Hazard Communication Standard as promulgated through the Occupational Safety 

and Health Act of 1970 and documented in the Code of Federal Regulations, Title 29, Chapter XVII, Part 1910, Section 1910.1200.  
The  inherent low hazard due to the AGW-0500’s design and construction, coupled with the safety features, monitoring data, and the 
precautionary directions provided in the owner’s manual are sufficient for The Toxicology Group, LLC, a division of NSF International 
(Ann Arbor, MI), to provide a professional opinion that the AGW-0500 Mobile Ozone Surface Sanitation System poses no safety 
concerns  when operated under the prescribed conditions as set forth in the owner’s manual.

ANTIMICROBIAL CLAIMS

This device has been determined acceptable for use as an ozone generating device providing sanitization and disinfection of hard, 
inanimate, pre-cleaned surfaces, in and around food processing areas (P1). A potable water rinse is not required following the use of 
this device on previously cleaned hard surfaces.  

NSF International Registration for this device is based, partially, upon documentation indicating that it meets all necessary requirements 
including labeling, EPA Establishment Registration, and safety requirements set forth under Federal Insecticide, Fungicide, and 
Rodenticide Act (FIFRA) of June 5, 1947, Section 2(q)(1) and Section 7. 

Efficacy studies conducted according to AOAC Official Method 961.02; Germicidal Spray Products as Disinfectants Test and AOAC 
Official Method 960.09*; Germicidal and Detergent Sanitizing Action of Disinfectants provided the following results:

Organism

Applied Dose

Actual Dose (at nozzle)

Spray Duration

Reduction

Trichophyton mentagrophytes 
(ATCC 9533)

3.0 ppm

1.85-2.25 ppm

30 seconds

 6 log (99.9999%)

Salmonella choleraesuis 
(ATCC 6538)

3.0 ppm

1.85-2.25 ppm

3 minutes

 6 log (99.9999%)

Staphylococcus aureus 
(ATCC 6538)

3.0 ppm

1.85-2.25 ppm

10 minutes

6 log (99.9999%)

Pseudomonas aeruginosa (ATCC 
15442)

3.0 ppm

1.85-2.25 ppm

5 minutes

6 log (99.9999%)

Campylobacter jejuni 
(ATCC 15442)

3.0 ppm

1.85-2.25 ppm

3 minutes

4 log (99.99%)

Listeria monocytogenes 
(ATCC 7644)

3.0 ppm

1.85-2.25 ppm

3 minutes

4 log (99.99%)

Aspergillus flavus 
(ATCC 9296)

3.0 ppm

1.85-2.25 ppm

5 minutes

4 log (99.99%)

Brettanomyces bruxellensis 
(ATCC 10560)

3.0 ppm

1.85-2.25 ppm

3 minutes

4 log (99.99%)

Escherichia coli* 
(ATCC 11229)

3.0 ppm

2.1 ppm

30 seconds

5 log (99.9999%)

Summary of Contents for MPI-300

Page 1: ...Installation Operations Manual 3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com 4 0700 Rev E MPI 300 Multi Point Intervention Ozone Sanitation System...

Page 2: ...orth in the owner s manual ANTIMICROBIAL CLAIMS This device has been determined acceptable for use as an ozone generating device providing sanitization and disinfection of hard inanimate pre cleaned s...

Page 3: ...3D Standard Operating Procedures 3 SECTION 4 Maintenance Service 4A PM Schedule 4 4B Trouble Shooting 4 SECTION 5 Replacement Parts 5A Ordering Information 4 5B Standard Replacement Parts List 4 SECTI...

Page 4: ...M min Weights Dimensions 25 5 H x 24 5 W x11 D 100 lbs Ambient Temp 40 F 90 F not to exceed 90 F 1C Layout Accessories The MPI 300 is a low pressure ozone enriched cold water surface sanitizer Interna...

Page 5: ...ed to a location close to your process This can be a level location either indoors or outdoors For all systems allow for access to protected electrical power and required water connections The point o...

Page 6: ...inal sanitizing rinse leaving no residual 3D 1 Surface Sanitation The spray can be directed on all wettable wood metal concrete and plastic surfaces including floors drains walls conveyors containers...

Page 7: ...numerical reading SECTION 4 MAINTENANCE AND SERVICE 4A Preventative Maintenance Schedule DAILY 1 Check ozone generator for proper operation Make sure green indicator lights are lit during operation MO...

Page 8: ...0 1 0 2 770 3740 0 2 6 7 1 1 2 5 Rotavirus 0 006 0 06 3810 6480 0 2 2 1 0 01 0 05 G lamblia cysts 0 5 0 6 47 150 G muris cysts 1 8 2 0 1400 7 2 18 5 30 630 6A 2 Materials Selection Materials Aqueous O...

Page 9: ...one to which workers may be exposed averaged over 8 hours 5 days a week OSHA Gaseous ozone concentrations above 0 02 PPM are detectable by humans Inasmuch sections 6C through 6H of this manual discuss...

Page 10: ...ure times ranging from 5 minutes to 10 hours 6D 2 Ventilation It is mandatory that general and local exhaust ventilation be provided to dilute and disperse small amounts of ozone into the outside atmo...

Page 11: ...34 may be used for personnel or area monitoring for exposure times ranging from 5 minutes to 10 hours For higher resolution the ChromAir ozone badge may be used in conjunction with the ChromAir ozone...

Page 12: ...ng has ceased start artificial respiration rescue breathing is the most effective method until breathing has been restored 2 Send for medical assistance immediately 3 If absent begin cardiopulmonary r...

Page 13: ...10 MPI 300 Installation Operations Manual APPENDIX A DAILY DATA LOG...

Page 14: ...11 MPI 300 Installation Operations Manual APPENDIX A...

Page 15: ...12 MPI 300 Installation Operations Manual APPENDIX B EMERGENCY INFORMATION...

Page 16: ...13 MPI 300 Installation Operations Manual...

Page 17: ...14 MPI 300 Installation Operations Manual APPENDIX C SAFETY...

Page 18: ...pping Classification NON REGULATED I PHYSICAL DATA Boiling Point 212 F Freezing Point 32 F Specific Gravity 1 0 Solubility in Water COMPLETE Evaporation Rate APPROX 1 Physical Form LIQUID Appearance O...

Page 19: ...prevent irritation and drying of the skin V EMERGENCY AND FIRST AID PROCEDURES Eye Contact If exposure to water containing aqueous solution of ozone causes irritation to eyes flush eyes with plenty of...

Page 20: ...e periodic exposure levels established by OSHA for worker safety through the use of DEL s ozone management technology Precautions To Be Taken In Handling Aqueous solutions of ozone in potable water sh...

Page 21: ...E WARRANTED ONLY FOR THE BALANCE OF THE ORIGINAL TWO 2 YEAR WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT AND MAINTENANCE PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WA...

Page 22: ...3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001...

Reviews: