4
MPI-300
Installation & Operations Manual
Sanitation Recommendations
STEP 1
Hot Water
STEP 2
Ozone Enriched
Cold Water
1. Total reduction of Aceto-
bacter (which contributes
to Volatile Activity)
2. Total Reduction of Brettan-
omyces (or all wild yeasts)
3. Overall barrel freshning
None
1.0-3.0 MInutes
4. Light
1.0 Minute 1.5 MInute
5. Heavy
2.0 MIn-
utes
2.0 Minutes
3D-3. Direct Food Contact - Spray Nozzles
Applications vary. Please contact DEL Ozone for
advice/consultation at 800-676-1335.
3D-4. Testing Dissolved Ozone Level (HACH) in
System Effluent Water Flow
Materials Required
1. HACH Indigo Blue AccuVac high range dis-
solved ozone test kit (DEL P/N 6-0116)
2. 5 gallon plastic pail (pre-cleaned)
3. Cold potable supply water for MPI-300
Procedure
1. Familiarize self with HACH AccuVac test kit.
2. Start-up MPI-300, place and hold spray wand in
5 gallon pail, and allow to flow for three to four
minutes (NOTE: ensure the tip of the spray
wand is approximately two inches above the
bottom of the pail).
3. Thoroughly rinse hands, ampule, and plunger
under the pail’s overflow for one minute.
4. Immediately take a water sample using the
ampule (following the HACH instructions) from
the middle of the pail at least one inch below
the water surface.
5. Gently shake the ampule.
6. Immediately compare the color of the ampule to
7. the supplied color wheel with thumb covering
the numerical readings. Once a color match is
determined, move thumb and take numerical
reading.
SECTION 4 MAINTENANCE AND
SERVICE
4A. Preventative Maintenance Schedule
DAILY:
1. Check ozone generator for proper operation.
- Make sure green indicator lights are lit during
operation.
MONTHLY:
1. Turn off system, unplug from power.
2. Remove and clean air filter located under “dry
section.”
- Remove plastic cover.
-
Rinse filter in warm, soapy water and allow to dry.
- Replace filter. (DEL P/N 7-1153)
3. Perform general cleaning of cabinet exterior.
4. Using clean/dry compressed air, blow out the
interior of cabinet, taking special care around
small components and wiring.
5. Check for debris in the debris screen located in
the source water inlet fitting. Clean & reinstall.
6. Check air in the tires and their general
condition.
ANNUALLY:
1. Remove and replace compressor air filter
cartridge using DEL P/N 7-1132.
EVERY 10,000 HOURS:
1. Rebuild compressor.
- Purchase compressor rebuild kit. (DEL P/N
2-1007 - See Section 5B for ordering infor-
mation)
- Follow instructions in compressor rebuild kit.
EVERY 18,000 HOURS:
1. Replace ozone generation cell. (DEL P/N 9-0925)
4B. Trouble Shooting
Knowledge of electrical applications is required
for trouble shooting. Contact a certified electrician
if you are unsure of your ability to service the
equipment. If any condition persists, call 800-676-
1335 or for international call 805-541-1601 for
technical assistance.
Symptom: “OZONE ON” green indicator light out
when switch is in the “ON” position and “PUMP ON”
light is on.
1. Check inside control panel for fault lights.
a. See Low Vac & Hi Temp fault light sections.
2. Check internal fuse.
a. Replace if blown. (3 amp - AGC 3)
3. Cabinet door ajar.
a. Close and latch door.
Summary of Contents for MPI-300
Page 13: ...10 MPI 300 Installation Operations Manual APPENDIX A DAILY DATA LOG...
Page 14: ...11 MPI 300 Installation Operations Manual APPENDIX A...
Page 15: ...12 MPI 300 Installation Operations Manual APPENDIX B EMERGENCY INFORMATION...
Page 16: ...13 MPI 300 Installation Operations Manual...
Page 17: ...14 MPI 300 Installation Operations Manual APPENDIX C SAFETY...