Connecting the charger
WARNING –
Lithium polymer batteries are volatile
. Failure to read and follow these instructions may
result in fire, personal injury, and damage to property if charged or used incorrectly. To prevent injury or
damage:
l
Use only the charger specified to charge the battery.
l
Use the charger to charge only UX5 HP batteries.
l
Always check that the settings on the charger are correct before charging the battery. Incorrect
charger settings may result in damage to the battery, severe burning and fire hazards.
l
Always remove the battery from the rover body for charging or storing.
WARNING –
Never leave the charger unattended during use. Failure to observe and operate the
charger properly can cause damage to the charger, battery, personal property and/or cause serious
personal injury.
WARNING –
The maximum charging current for the UX5 HP battery is limited to 5 A. This value must be
lower than the maximum permissible current (6 A) for the battery. Incorrect battery charging parameters
can destroy your battery and cause it to catch fire or explode.
1. If the battery is fitted in the rover,
remove the battery from the rover
body.
2. Connect the Graupner Ultramat 14 Plus charger to one of the following:
l
11–15 V DC (vehicle battery)
l
100–240 V AC (power supply)
The charger powers on and displays the charge parameters.
3. Make sure the charger settings are correct. The parameters should be:
l
LiPo manual
l
C:5.0A 6600mAh
Press the
Prog/Mode
key to check the voltage per cell. When:
l
Charging the battery for a flight, the voltage should be 4.20V/C
l
Preparing the battery for storage, the voltage should be 3.90V/C
Press the
Prog/Mode
key to return to the main screen. If the settings shown are not correct, change
them using the steps below.
If the charge program is incorrect:
a. Press and hold the
Prog/Mode
key for two seconds to navigate through the charge modes.
Repeat this action until the charger screen shows "LiPo/LiIo/LiFe manual".
b. Press the
Prog/Mode
key and then press the
DEC
or
INC
key until the type is set to "LiPo".
c. Press the
Prog/Mode
key to return to the main screen.
To change the voltage per cell:
a. Press the
Prog/Mode
key to select the voltage per cell setting. The entry "X.XXV/C" blinks. Press
the
DEC
or
INC
key to change the value until it is set to "4.20V/C" for charging or "3.90V/C" for
61
Delair-Tech
|
676, Rue Max Planck – 31670 Toulouse-Labège, France
|
Tel: +33 (0) 5 82 95 44 06
|
Capital: 238 110,30 € - APE: 3030Z – Intra-Community VAT number: FR90 53 09 69 781 – 530 969 781 R.C.S. Toulouse
This document is the sole property of Delair-Tech and cannot be used or reproduced without the written authorization of Delair-Tech
.