Service
DeLaval milking point controller MPCII
94381001.pdf
2006-07-20
4. The ALPRO processor from version 6.30
automatically sets the MPCII in BOOT
position for program loading. The MPCII
display shows RESET.
Sets the MPCII in the BOOT mode for
application program loading.
During programming the number of files or
batches of files are displayed. The amount
of data left to download is displayed
counting down.
When the application program has been
loaded DONE is displayed.
The MPCII enters the application program
mode.
To leave the application mode and enter the
stand by mode press F and ↑.
The last loaded application program is the
active one.
If ESC is pressed on the ALPRO processor
during application program loading, the
MPCII display indicates TM OUT.
The MPCII is blocked in BOOT mode and
the program loading procedure must be
completed from the ALPRO processor.