Operation
DeLaval milking point controller MPCII
94381001.pdf
2006-07-20
325
Sweep delay
20 /10 sec (1-9.9)
326
Sweep duration
10/10 sec (0.1-9.9)
327
Low-flow limit
2 /10 kg/min (0.1-0.5)
328
Alfa-dast, time 1 30 sec (15-60)
329
Alfa-dast, time 2 15 sec (1-30)
330
Alfa-dast, time 3 5 sec (1-30)
331
Duovac/Monovac
0 = Duovac (default), 1 = Monovac
332
Pulsator rate
60 ppm (50, 60)
333
Pulsator ratio
65 % (60, 65, 70)
334
Strip limit
5/10 kg/min (0.1-1.5)
335
Take-off limit / post-milking limit
2 kg/min/10
With password 6285 (0.1-0.6)
with password 6286 (0.7-1.1)
337
Vacuum on delay
0 sec (0-5 sec programmed as 1-50 in steps
of 0.1 sec)