Manual forced vacuum time.
This is the
maximum time during which high vacuum is
activated after you have pressed the
Manual forced vacuum
button.
F323
Post-milking time.
This is the duration of
the post-milking.
See time
A
in the diagram.
This timer will restart every time the MPCII
enters post-milking phase.
F324
Take-off delay.
Delay between vacuum
shut-off and retraction.
See time
B
in the
diagram.
F325
Sweep delay.
Delay between retraction and
start sweep.
See time
C
in the diagram.
F326
Sweep duration.
Time
D.
See
①
in the
diagram.
F327
Low-flow limit/pre-milking limit.
The flow
limit when the MPCII switches from
pre-milking phase to main milking phase.
F328
AlfaDast, strip time 1.
See AlfaDast ST1!
F329
AlfaDast, strip time 2.
See AlfaDast ST2!
F330
AlfaDast, strip time 3.
See AlfaDast ST3!
F331
Duovac/Monovac.
If Duovac is not used,
set this parameter to YES (= 1)
F332
Pulsator rate.
F333
Pulsator ratio.
F334
Strip limit.
Used in AlfaDast only. The flow
limit when the strip is activated and the
stripping phase begins.
F335
Take-off limit/post-milking limit.
ACR has been installed:
The flow limit when
73(94)
Summary of Contents for MPCII
Page 1: ...MEMO Internal use DeLaval milking point controller MPCII 2006 07 20 0605 94381001 pdf ...
Page 2: ......
Page 13: ...Installation MPCII AlfaDast 94381001 pdf 2006 07 20 MPCII AlfaDast Installation 5 94 ...
Page 16: ...Installation MPCII AlfaDast 94381001 pdf 2006 07 20 8 94 ...
Page 26: ...Installation MPCII herringbone 94381001 pdf 2006 07 20 18 94 ...
Page 30: ...Installation MPCII In parlour feeding 94381001 pdf 2006 07 20 22 94 ...
Page 36: ...Installation MPCII MidiLine 94381001 pdf 2006 07 20 28 94 ...
Page 46: ...Installation MPCII Tandem 94381001 pdf 2006 07 20 38 94 ...
Page 102: ...Troubleshooting DeLaval milking point controller MPCII 94381001 pdf 2006 07 20 94 94 ...