Operation
DeLaval milking point controller MPCII
94381001.pdf
2006-07-20
F75 – Local mode
System
This function disconnects this place from
the bus, and the MPCII will work as a
Stand-alone if this parameter is set to 1.
The "communication interrupted" LED will
light up
-
To connect to the bus, press F75↑ 0
again,
the password is 6285.
F76 – Test mode
System and stand-alone
Pressing F, 7, 6, and ↑ on the MPCII sets
the MPCII in test mode.
If a rodreader is connected and there is
transponder within reading range, the
transponder number is displayed as "Txxxx".
As soon as the transponder is removed the
number will disappear from the display.
To finish, press F72 and ↑ or F2 ↑.
Test of inputs:
Test of inputs:
1
= remote gate
1
= remote gate
2
= Not used/HB; Photocell in the box/VT; box MPCII; photocell out right/VT, special MPCII; position
switch/Rot place MPCII
2
= Not used/HB; Photocell in the box/VT; box MPCII; photocell out right/VT, special MPCII; position
switch/Rot place MPCII
3
= remote release; VT special MPCII left side out/photocell; photocell special MPCII rotary
3
= remote release; VT special MPCII left side out/photocell; photocell special MPCII rotary
4
= gate switch, installed at left side of the parlour; VT special MPCII Photocell/right side in
4
= gate switch, installed at left side of the parlour; VT special MPCII Photocell/right side in
5
= gate switch, installed at right side of the parlour; VT special MPCII Photocell/left side in
5
= gate switch, installed at right side of the parlour; VT special MPCII Photocell/left side in
Test of outputs:
Test of outputs:
F700
Deactivates all outputs
F700
Deactivates all outputs
F701
Activates output 1
(ACR cylinder)
F701
Activates output 1
(ACR cylinder)
F702
Activates output 2
(ACR ISO)
F702
Activates output 2
(ACR ISO)
F703
Activates output 3
(Duovac)
F703
Activates output 3
(Duovac)
F704
Activates output 4
(auxiliary 1)
F704
Activates output 4
(auxiliary 1)
F705
Activates output 5
(EP valve 1)
F705
Activates output 5
(EP valve 1)
F706
Activates output 6
(EP valve 2)
F706
Activates output 6
(EP valve 2)
F707
Activates output 7
(right gate valve)
F707
Activates output 7
(right gate valve)
F708
Activates output 8
(left gate valve)
F708
Activates output 8
(left gate valve)
F709
Activates output 9
(alarm lamp)
F709
Activates output 9
(alarm lamp)
F710
Activates output 10
(auxiliary 2)
F710
Activates output 10
(auxiliary 2)
F711
Activates output DCO/V (V COM) (only if EP50 is used)**
F711
Activates output DCO/V (V COM) (only if EP50 is used)**
F715
Pulsator test
F715
Pulsator test
F800
Deactivates all LEDs
F800
Deactivates all LEDs
75(94)
Summary of Contents for MPCII
Page 1: ...MEMO Internal use DeLaval milking point controller MPCII 2006 07 20 0605 94381001 pdf ...
Page 2: ......
Page 13: ...Installation MPCII AlfaDast 94381001 pdf 2006 07 20 MPCII AlfaDast Installation 5 94 ...
Page 16: ...Installation MPCII AlfaDast 94381001 pdf 2006 07 20 8 94 ...
Page 26: ...Installation MPCII herringbone 94381001 pdf 2006 07 20 18 94 ...
Page 30: ...Installation MPCII In parlour feeding 94381001 pdf 2006 07 20 22 94 ...
Page 36: ...Installation MPCII MidiLine 94381001 pdf 2006 07 20 28 94 ...
Page 46: ...Installation MPCII Tandem 94381001 pdf 2006 07 20 38 94 ...
Page 102: ...Troubleshooting DeLaval milking point controller MPCII 94381001 pdf 2006 07 20 94 94 ...