8
Part Number: 9291456 11/17
Installation
Section 2
N225 & N227 STANDARD INSTALLATION DETAILS
For any non-standard installation consult the factory.
1. Install a GFCI receptacle a minimum of 14” (36cm) up
from the cabinet bottom inside the partitions.
2. Cabinet interior minimum dimensions:
Dimensions
N225-E, N225P
N227-E, N227P
A
21.50” (55cm)
29.62” (75cm)
B
29.38” (75cm)
29.38” (75cm)
C
26.00” (66cm)
26.00” (66cm)
D
16.12” (41cm)
29.62” (75cm)
E
26.62” (68cm)
26.62” (68cm)
F
Minimum 2.75” (7cm), Maximum 7.0” (18cm)
23.50”
(60cm)
C
E
D
A
B
12.0”
(30cm)
14.0”
(36cm)
10.0”
(25cm)
F
3. Place the condensing unit through the counter cutout.
4. Extend the telescoping duct from the front of the
condensing unit to the back of the louver. Export
models do not have a telescoping duct, skip to step 6.
5. Put eight provided screws through the telescoping
duct side walls to hold it at the desired depth.
Use Screws to Secure Desired Depth
3 of 8 Screws Shown
6. Partitions must fully extend front to back and top to
bottom.
7. Louver cutout must extend to bottom of cabinet and
align with condenser face.
NOTE: The louver provided must be installed in front of
the condensing unit’s finned coil. Any restriction to the
proper air flow will void the compressor warranty.
• Louver measures 13.00” x 25.00” (33cm x 64cm).
• Louver Cutout Size is 12.00” x 23.50” (30cm x 60cm)
(typical installation).
Finned C
oil
Duct
Partitions Not Shown
Louv
er
Typical Counter Cabinet