Installation
Section 2
10
Part Number: 9294839 03/17
Leveling
After the cabinet has been placed in the desired location,
cabinets with legs must be leveled. Level units from front to
back and from side to side. Leveling will insure proper door
operation and removal of condensate. Cabinets with casters
must have the caster brake set so the cabinet cannot move.
Stabilizing
It is very important that all legs are properly adjusted to
keep the cabinet level, evenly distribute the weight and to
make sure the unit will not rock, lean or be unstable.
Leg & Caster Installation
DANGER
Legs or casters must be installed and the legs or casters
must be screwed in completely to prevent bending.
When casters are installed the mass of this unit will
allow it to move uncontrolled on an inclined surface.
These units must be tethered/secured to comply with
all applicable codes.
n
Warning
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owner’s and operator’s responsibility.
n
Warning
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg/caster. Place blocking
underneath the unit. Do not work underneath a raised
unit without proper blocking. Do not lift the unit more
than necessary to remove the leg/caster. Lifting the unit
too far can make the unit unstable.
,
Caution
All single-section units require that the swivel casters be
mounted on the front and rigid casters be mounted on
the rear.
To install the legs or casters:
1. Remove unit from skid.
NOTE: The bolts used to hold the unit to the skid should
be re-used as the fourth hex head bolt for each caster
or leg plate installation. The bolt should not measure
over 2” (5cm) in length.
2. Raise unit to access leg/caster mounting holes on
bottom of unit.
3. Attach the legs or casters to bottom of cabinet using
hex head bolts.