Mechanical Data–Standard Unit
MODEL
GALLON
NUMBER OF
VOLTS/HERTZ
BTU DESIGN LOAD
BTU SYS. CAP.
SHIP
NUMBER CAPACITY
COVERS
H.P.
PHASE
AMPS
FRZR./RAIL
FRZR./RAIL
WEIGHT
F13BC44
24
4
1/3
115/60/1
8.0
506/192
983/828
435 lbs/ 197 kg
F13BC56
36
6
1/3
115/60/1
8.0
638/250
1073/979
480 lbs/ 218 kg
F13BC72
48
8
1/2
115/60/1
10.0
796/307
1309/1174
540 lbs/ 245 kg
5-15P NEMA plug used on all lengths.
J
EXPANSION VALVES FOR BASE & RAIL
V
LEGEND
CONDENSING UNIT WIRED TO J-BOX 25" A.F.F..
J-BOX TO HAVE ON/OFF SWITCH AND 8' CORD
AND PLUG ATTACHED, REAR OF COMP.
OPEN TO EXIT CORD
J
31.50"
(80.0)
14"
(35.6)
44" (111.8)
30" (76.2)
42" (106.7)
56" (142.2)
54" (137.2)
72" (182.9)
17"
(43.2)
44" (111.8)
56" (142.2)
72" (182.9)
SMALL LID
ALL UNITS
9.25"
(23.5)
PLAN VIEW
F13BC44
PLAN VIEW
F13BC56
PLAN VIEW
F13BC72
ELEVATION VIEW
F13BC44
ELEVATION VIEW
F13BC56
ELEVATION VIEW
F13BC72
46.37"
(117.8)
SIDE VIEW
ALL UNITS
14"
(35.6)
18"
(45.7)
V V
V V
6.12"
(15.6)
7.62"
(19.4)
21.31"
(54.1)
36"
(91.4)
23.75"
(60.3)
31.5"
(80)
12"
(30.5)
46.37"
(117.8)
F13BC
The Delfield Company, P.O. Box 470, Mt Pleasant, MI 48804-0470, U.S.A. • (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. ©2001 The Delfield Company. All rights reserved. Printed in U.S.A.
DS13BC 02/01
31.5” (80cm) Deep Self-Contained Low Temp, Ice Cream Cabinets with Syrup Rail