background image

Section 6 

Service Information

Part Number: 9291545  REV00  11/20 21

DOOR ASSEMBLIES

Part #

Description

F18DC48P

 

(PR/PL)

F18DC72P

 

(PR/PL)

F18DC99P

 

(PR/PL)

000-187-00FU-S Door assembly, 24”, RT 

23.75” x 25.72” (60cm X 65cm) 

X

000-187-00FV-S Door assembly, 24”, LT  

23.75” x 25.72” (60cm X 65cm) 

X

000-187-00FW-S Door assembly, 27”, RT  

26.75” x 25.72” (68cm X 65cm) 

X X

000-187-00FX-S Door assembly, 27”, LT  

26.75” x 25.72” (68cm X 65cm) 

X X

1701184

Gasket, door, 24” (61cm)

X

1701185

Gasket, door, 27” (69cm)

X X

0160179

Hinge kit, complete  

(for right or left hinged doors)

X

3234072

Hinge, door, top/LH, bottom/RH

X

3234073

Hinge, door, top/RH, bottom/LH

X

9321107

Bushing, nylon, hinge pin 

X

3234391

Hinge, Door, L-Shaped

X

Condensing Unit Assemblies

Part #

Description

F18DC48P

 

(PR/PL)

F18DC72P

 

(PR/PL)

F18DC99P

 

(PR/PL)

000-BN5-004F-S

Dual Condensing unit,

1/3hp & 1/4hp, 115V

X

000-BN5-004G-S Dual Condensing unit,

1/3hp & 1/5hp, 115V

X X

3527163

R290 Compressor 1/4hp

X

3527162

R290 Compressor 1/5hp

X X

3527193

R290 Compressor 1/3hp 

X

1703017

Condensate Pan

X

3510017

Condensing Coil

X

2160019

Condensor Fan Guard

X

2162513

Fan Motor, 35w

X

3510021

Fan Blade

X

3516478

Filter Dryer .25” inlet

X

2190000

Relay

X

3510001

Low Pressure Switch

X

000-SCH-0156

Wiring Schematic

X

Summary of Contents for F18DC48P-RCPL

Page 1: ...is updated as new information and models are released Visit our website for the latest manual Part Number 9291545 Rev00 11 20 Original Document Caution Read this instruction before operating this equipment Fresh Solutions Fit For You Refridgerated Catch Pan Raised Rail Pizza Table ...

Page 2: ... or any other appliance Never use flammable oil soaked cloths or combustible cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carb...

Page 3: ... Installation 10 Refrigeration 10 Section 3 Operation Make Tables 11 Instructions for Optimal Performance 12 Evaporator Fan Operation 13 ERC112 Temperature Control 13 At Start Up 13 Defrost 13 Operation 14 Changing Display from Fahrenheit to Celsius on ERC112 Control 15 Section 4 Maintenance Responsibility 16 Interior Cleaning 17 Gaskets 17 Preventing Blower Coil Corrosion 17 Exterior Cleaning 17 ...

Page 4: ...11 20 Table of Contents continued Section 6 Service Information Wiring Diagrams For All Models 19 Replacement Parts 20 Mullion Coil Assemblies 20 Door Assemblies 21 Condensing Unit Assemblies 21 Miscellaneous Replacement Parts 22 ...

Page 5: ...the three rating plates The rating plate is located behind the louvered door Always have the serial number of your unit available when calling for parts or service Warranty Information Visit www delfield com warranty to Register your product for warranty Verify warranty information View and download a copy of your warranty Regulatory Certifications Makelines are certified by National Sanitation Fo...

Page 6: ...General Information Section 1 6 Part Number 9291545 REV00 11 20 THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 7: ...sate line to a suitable drain Otherwise water will collect on the floor causing a potentially hazardous situation nWarning Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees It is the owners responsibility to provide a container or outlet for drainage The location selected for the equipment must meet the following criteria If any of thes...

Page 8: ...0ft2 3159cm2 108lbs 49kg 6 22ft3 176L F18DC48P RCPL 1 24 61cm 3 40ft2 3159cm2 108lbs 49kg 6 22ft3 176L F18DC72P RCPR 2 27 69cm 7 90ft2 7339cm2 125lbs 57kg 13 11ft3 371L F18DC72P RCPL 2 27 69cm 7 90ft2 7339cm2 125lbs 57kg 13 11ft3 371L F18DC99P RCPR 3 27 69cm 11 85ft2 11009cm2 125lbs 57kg 19 69ft3 558L F18DC99P RCPL 3 27 69cm 11 85ft2 11009cm2 125lbs 57kg 19 69ft3 558L Weight Of Equipment Custom Mo...

Page 9: ... connections to verify they are tight before start up Ground Fault Circuit Interrupter Ground Fault Circuit Interrupter GFCI GFI protection is a system that shuts down the electric circuit opens it when it senses an unexpected loss of power presumably to ground Welbilt does not recommend the use of GFCI GFI circuit protection to energize our equipment If code requires the use of a GFCI GFI then yo...

Page 10: ...n create a slipper surface on the floor and a hazard to employees It is the owner s responsibility to provide a container or outlet for drainage Leg Caster Installation DANGER Legs or casters must be installed and the legs or casters must be screwed in completely to prevent bending When casters are installed the mass of this unit will allow it to move uncontrolled on an inclined surface These unit...

Page 11: ...t in damage to the interior of the cabinet or to the blower coil Make Tables Delfield refrigerated bases are designed to maintain an operational temperature of 36 F to 40 F 2 C to 4 C Self contained units with a cord and plug have an ON OFF switch located directly behind the louvered panel covering the compressor section Simply turn the switch to ON to begin operation Temperature in the rail is de...

Page 12: ...y the excess food product in the catch pans after two hours of use throughout the work day to achieve the best temperatures However the catch pans are capable of maintaining temperatures up to four hours if needed 5 At the end of the operation the top rail catch pan switch must be turned to the OFF position The cabinet main switch remains ON The rail frost will melt and flow down the drain line Pr...

Page 13: ...mplete This initial defrost cycle may take up to 35 minutes to complete 3 The display will continue to read dEF for an additional 30 minutes while the cooling cycle cools the box to the set temperature 4 Then the digital thermostat will display box temperature 5 The temperature control will cycle the compressor evaporator fan motor and condenser fan motor to maintain box temperature at the control...

Page 14: ...a high ambient temperature or not shutting the rail off nightly All alarms sound for approximately 10 seconds and then are silent for 50 seconds It will do that for 15 cycles and then remain silent The alarm code will still be present on the display until the fault clears Press upper or lower right button Display show actual set point blinking If buttons untouched for 3 seconds returns to normal I...

Page 15: ... push the stand by button lower left button to enter into the display menu 5 Scroll to CFu using the up down arrows and push the stand by button lower left button to enter the display unit menu 6 F should be displayed indicating Fahrenheit Use the down arrow to change it to C for Celsius and hit the stand by button lower left button to enter the change 7 Push the defrost button upper left button t...

Page 16: ...es or other means to accelerate the defrosting process nWarning When using cleaning fluids or chemicals rubber gloves and eye protection and or face shield must be worn Caution Over shelves and other items mounted to the top of the counters should never be installed in the field due to the potential damage to the refrigeration system Caution Maintenance and servicing work other than cleaning as de...

Page 17: ...ads for cleaning Never use chlorinated citrus based or abrasive cleaners Stainless steel exterior panels have a clear coating that is stain resistant and easy to clean Products containing abrasives will damage the coating and scratch the panels Daily cleaning may be followed by an application of stainless steel cleaner which will eliminate water spotting and fingerprints Early signs of stainless s...

Page 18: ...re too warm Check rail on off to make sure it is on Check rail for ice buildup If a thick layer of ice is present shut unit off and allow unit to defrost Verify condenser coil is clean Verify thermostat setting Top rail not holding temperature too cold Verify thermostat setting Refrigerated base not holding temperature Check base thermostat Verify doors are closing properly and gaskets are sealing...

Page 19: ... 9291545 REV00 11 20 19 Wiring Diagrams For All Models Control Schematic 000 SCH 0162 Compressor Schematic 000 SCH 0156 Section 6 Service Information Note All wiring diagrams are for trained professional use only ...

Page 20: ...ns X 2160024 Guard fan 4 7 X 2160023 Fan axial EC 120V 60Hz X 3510005 Coil evaporator X 030 232 0003 Back evaporator enclosure X 3517414 Expansion valve 1 4 R290 X 030 233 0001 Side coil angled Right X 030 233 0002 Side coil angled Left X 000 BNH 0030 Drain pan X 030 234 0003 Front coil X 2184317 Harness coil X 2194808 Probe Defrost Danfoss Control X 2194809 Probe Temp Sensor Danfoss X F18DC99P RC...

Page 21: ...t or left hinged doors X 3234072 Hinge door top LH bottom RH X 3234073 Hinge door top RH bottom LH X 9321107 Bushing nylon hinge pin X 3234391 Hinge Door L Shaped X Condensing Unit Assemblies Part Description F18DC48P PR PL F18DC72P PR PL F18DC99P PR PL 000 BN5 004F S Dual Condensing unit 1 3hp 1 4hp 115V X 000 BN5 004G S Dual Condensing unit 1 3hp 1 5hp 115V X X 3527163 R290 Compressor 1 4hp X 35...

Page 22: ... X X X 000 B2G 0043 S Overshelf Assembly 48 122cm unit X 000 B2G 0042 S Overshelf Assembly 72 183cm unit X 000 B2G 0040 S Overshelf Assembly 99 251cm unit X 409 B92 0043 S Overshelf sliding cover 48 122cm unit X 409 B92 0042 S Overshelf sliding cover 72 183cm unit X 409 B92 0040 S Overshelf sliding cover 99 251cm unit X 3234242 Plastic Drain 1 25mm diameter X X X 3977998 Shelf 24 61cm door X 39780...

Page 23: ...nformation Part Number 9291545 REV00 11 20 23 Drawer Assembly 2 3 1 KEY PART NUMBER DISCRIPTION QUANTITY 1 000 373 004D DRAWER BOX ASSEMBLY 1 2 000 315 0036 DRAWER MULLION ASSEMBLY 1 3 000 328 0049 27 Drawer Front 2 Hi 2 ...

Page 24: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9291545 Rev00 11 20 ...

Reviews: