F18 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
4
Delfield
™
®
Specifications
MODEL
# OF
SHELF AREA
# OF
RECOMMENDED
VOLTS/HERTZ/
BTU DESIGN
EVAP. CAP.
NUMBER
DOORS
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BTU/°TD
Remote Refrigerated Salad Top Tables
F18SR31A
(1) 19”
2.56
6
1/4
115/60/1
3.0
280/265
120
F18SR44A
(2) 19”
5.12
6
1/4
115/60/1
3.0
491/441
120
F18SR44B
(2) 19”
5.12
8
1/4
115/60/1
3.0
491/441
120
F18SR44C
(2) 19”
5.12
10
1/4
115/60/1
3.0
491/441
120
F18SR52A
(1) 19” & (1) 27”
6.51
6
1/4
115/60/1
3.0
532/529
120
F18SR52B
(1) 19” & (1) 27”
6.51
8
1/4
115/60/1
3.0
532/529
120
F18SR52C
(1) 19” & (1) 27”
6.51
10
1/4
115/60/1
3.0
532/529
120
F18SR52D
(1) 19” & (1) 27”
6.51
12
1/4
115/60/1
3.0
532/529
120
MODEL
# OF
SHELF AREA
# OF
VOLTS/HERTZ/
BTU DESIGN
BTU SYSTEM CAP.
NUMBER
DOORS
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BASE/RAIL
Self-Contained Refrigerated Salad Top Tables
F18SC39A
(1) 19”
2.56
6
1/4
115/60/1
10.0
280/265
1903/745
F18SC39B
(1) 19”
2.56
8
1/4
115/60/1
10.0
280/353
1903/867
F18SC52A
(2) 19”
5.12
6
1/4
115/60/1
10.0
444/265
1903/745
F18SC52B
(2) 19”
5.12
8
1/4
115/60/1
10.0
444/353
1903/867
F18SC52C
(2) 19”
5.12
10
1/4
115/60/1
10.0
444/441
1903/971
F18SC52D
(2) 19”
5.12
12
1/4
115/60/1
10.0
444/529
1903/1061
F18SC60A
(2) 19” & (1) 27”
6.51
6
1/4
115/60/1
10.0
515/265
2314/667
F18SC60B
(2) 19” & (1) 27”
6.51
8
1/4
115/60/1
10.0
515/353
2314/798
F18SC60C
(2) 19” & (1) 27”
6.51
10
1/4
115/60/1
10.0
515/441
2314/916
F18SC60D
(2) 19” & (1) 27”
6.51
12
1/4
115/60/1
10.0
515/529
2314/1023
A 5-15P NEMA plug is used on self-contained units
MODEL
# OF
STORAGE
SHELF AREA
# OF
RECOMMENDED
VOLTS/HERTZ/
BTU DESIGN LOAD
EVAP. CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BTU/°TD
Remote Refrigerated Reduced Height Rail
F18DR44
(2) 19”
9.49
5.12
10
1/4
115/60/1
3.0
547/441
120/19
F18DR52
(1) 19” & (1) 27”
11.81
6.51
12
1/3
115/60/1
3.0
625/529
120/23
F18DR60
(2) 27”
14.14
7.9
16
1/3
115/60/1
5.0
703/617
120/26
F18DR70
(2) 32”
17.05
9.64
18
1/2
115/60/1
5.0
800/794
120/32
F18DR79
(1) 19” & (2) 27”
18.68
10.29
18
1/2
115/60/1
5.0
962/882
240/36
F18DR87
(3) 27”
21.30
11.85
22
3/4
115/60/1
5.0
1032/970
240/39
MODEL
# OF
STORAGE
SHELF AREA
# OF
VOLTS/HERTZ/
BTU LOAD
BTU SYSTEM CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BASE/RAIL
Self-Contained Refrigerated Reduced Height Rail
F18DC52
(2) 19”
9.49
5.12
12
1/4
115/60/1
10.0
547/529
1903/1061
F18DC60
(1) 19” & (1) 27”
11.81
6.51
14
1/3
115/60/1
12.0
625/617
2314/1121
F18DC68
(2) 27”
14.14
7.9
18
1/3
115/60/1
12.0
703/794
2314/1544
F18DC82
(2) 32”
17.05
9.64
20
1/2
115/60/1
14.0
800/882
3097/1648
F18DC91
(1) 19” & (2) 27”
18.68
10.29
22
1/2
115/60/1
14.0
962/1058
3807/1839
F18DC99
(3) 27”
21.30
11.85
24
3/4
115/60/1
16.0
1032/1147
5286/2191
A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99.