5
F18 Series Service and Installation Manual
5
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Delfield
™
®
Specifications
MODEL
# OF
STORAGE
SHELF AREA
# OF
RECOMMENDED
VOLTS/HERTZ/
BTU DESIGN LOAD
EVAP. CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BTU/°TD
Remote Refrigerated Reduced Height Rail
F18RR44
(2) 19”
9.49
5.12
10
1/4
115/60/1
3.0
547/441
120/19
F18RR52
(1) 19” & (1) 27”
11.81
6.51
12
1/3
115/60/1
3.0
625/529
120/23
F18RR60
(2) 27”
14.14
7.9
16
1/3
115/60/1
5.0
703/617
120/26
F18RR70
(2) 32”
17.05
9.64
18
1/2
115/60/1
5.0
800/794
120/32
F18RR79
(1) 19” & (2) 27”
18.68
10.29
18
1/2
115/60/1
5.0
962/882
240/36
F18RR87
(3) 27”
21.30
11.85
22
3/4
115/60/1
5.0
1032/970
240/39
MODEL
# OF
STORAGE
SHELF AREA
# OF
VOLTS/HERTZ/
BTU LOAD
BTU SYSTEM CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
PANS
HORSE POWER
PHASE
AMPS
BASE/RAIL
BASE/RAIL
Self-Contained Refrigerated Reduced Height Rail
F18RC52
(2) 19”
9.49
5.12
12
1/4
115/60/1
10.0
547/529
1903/1061
F18RC60
(1) 19” & (1) 27”
11.81
6.51
14
1/3
115/60/1
12.0
625/617
2314/1121
F18RC68
(2) 27”
14.14
7.9
18
1/3
115/60/1
12.0
703/794
2314/1544
F18RC82
(2) 32”
17.05
9.64
20
1/2
115/60/1
14.0
800/882
3097/1648
F18RC91
(1) 19” & (2) 27”
18.68
10.29
22
1/2
115/60/1
14.0
962/1058
3807/1839
F18RC99
(3) 27”
21.30
11.85
24
3/4
115/60/1
16.0
1032/1147
5286/2191
A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99.
MODEL
# OF
STORAGE
SHELF AREA RECOMMENDED
VOLTS/HERTZ/
BTU
EVAP. CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
HORSE POWER
PHASE
AMPS
LOAD
BTU/°TD
Remote Freezer Base
F18FR35
(1) 19”
5.58
2.56
1/3
115/60/1
10.0
943
160
F18FR50
(2) 19”
12.21
5.12
1/2
115/60/1
10.0
1471
160
F18FR58
(1) 19” & (1) 27”
15
6.51
3/4
115/60/1
10.0
1844
160
F18FR66
(2) 27”
17.79
7.9
3/4
115/60/1
10.0
2020
160
F18FR76
(2) 32”
21.28
9.64
3/4
115/60/1
10.0
2437
160
MODEL
# OF
STORAGE
SHELF AREA
VOLTS/HERTZ/
BTU
EVAP. CAP.
NUMBER
DOORS
CU. FT.
SQ. FT.
HORSE POWER
PHASE
AMPS
LOAD
BTU/°TD
Self-Contained Freezer Base
F18FC43
(1) 19”
5.58
2.56
1/3
115/60/1
10.0
943
1558
F18FC62
(2) 19”
12.21
5.12
1/2
115/60/1
12.0
1471
1776
F18FC70
(1) 19” & (1) 27”
15
6.51
3/4
115/60/1
16.0
1647
2713
F18FC78
(2) 27”
17.79
7.9
3/4
115/60/1
16.0
1824
2713
F18FC88
(2) 32”
21.28
9.64
3/4
115/60/1
16.0
2045
2713
A 5-15P NEMA plug is used on F18FC43 & F18FC62. A 5-20P NEMA plug is used on F18FC70, F18FC78 & F18FC88.