14
Delfield
CONTROL CONSOLE
The control console contains the data display and control
buttons (Figures 18 and 19) needed to operate the drawers.
The menus can be accessed by pressing and holding the
i
(Enter) button for approximately 5 seconds. The various
screens used to monitor unit operation and to change
settings will time out after 30 seconds. The exception is
the diagnostics screen which does not time out.
1
Drawer
2
Drawer
Drawer
Drawer
3
4
LEFT
(BACK)
DOWN
UP
ENTER
RIGHT
Figure 18. 4-Drawer Console Display
LEFT
(BACK)
DOWN
UP
ENTER
RIGHT
Figure 19. 2-Drawer Console Display
CHANGING DRAWER MODES
NOTE:
At anytime while using the control,
go back to the previous screen by
pressing the LEFT arrow.
1. Press the desired drawer tab on the display.
2. Press the UP or DOWN arrows to the desired mode
(Refrigerate, Freeze, Chill, or Thaw) (Figure 20).
NOTE:
The desired mode will display with
parenthesis when selected.
3. Press the drawer tab again to lock the desired
mode setting.
Figure 20. Drawer Mode Display
(2-Drawer Display shown)
CAUTION
Only qualified technicians should access the following
programming menus.
MANUAL DEFROST
NOTE:
Both buttons must be pressed within
one second to manually set defrost.
To manually set a drawer to defrost, press the desired drawer
tab (Figure 20) and then very quickly press
i
(Enter). To turn
off manual defrost, press the desired drawer tab and very
quickly press
i
(Enter).
PROGRAM MENU
NOTE:
At any time while using the control, go
back to the previous screen by
pressing the LEFT arrow.
The Program Menus can be accessed by pressing and
holding
i
(Enter) for five seconds.
Figure 21. Program Menu
(2-Drawer Display Shown)
1. Select the desired function by pressing the UP or
DOWN arrows (Figure 21).
2. Press
i
(Enter) to select the function.