background image

27

Versa Drawer Refrigeration Units

ADDITIONAL FOUR YEAR PROTECTION PLAN 

(for Motor-Compressor only)

Installation

Delfield

Installation

Model#

  Serial #

Date

In addition to the Standard One Year Warranty on the
Motor-Compressor contained in the above listed Delfield
product (the “Unit”), The Delfield Company (“Delfield”) also
agrees to repair, or exchange with similar or interchangeable
parts in design and capacity at Delfield’s option, the
defective Motor-Compressor contained in the Unit (the
“Motor-Compressor”), or any part thereof, for the Original
Purchaser only, at any time during the four (4) years
following the initial one (1) year period commencing on the
date of installation for the Original Purchaser. 

Failure of

the Original Purchaser to register the registration card
containing the Original Purchaser’s name, address,
date of installation, model number and serial number
of the Unit containing the Motor-Compressor within 30
days from the date of installation shall void this
warranty. 

This additional warranty is only available if the

Motor-Compressor is inoperative due to defects in material
or factory workmanship, as determined by Delfield in its
sole judgment and discretion. The Original Purchaser shall
be responsible for returning the defective Motor-Compressor
to Delfield prepaid, F.O.B. at the address shown on the
back cover of this manual.

The term “Original Purchaser” as used herein means that
person, firm, association or corporation for whom the Unit
was originally installed.

The term “Motor-Compressor” as used herein does not
include unit base, air- or water-cooled condenser, receiver,
electrical accessories such as relay, capacitors, refrigerant
controls, or condenser fan/motor assembly. This warranty
does not cover labor charges incidental to the replacement
of parts. This warranty further does not include any
equipment to which said condensing unit is connected,
such as cooling coils, temperature controls or refrigerant
metering devices. This warranty shall be void if the Motor-
Compressor, in Delfield’s sole judgment, has been
subjected to misuse, neglect, alteration or accident,
operated contrary to the recommendations specified by
the Unit manufacturer, repaired or altered by anyone other
than Delfield in any way so as, in Delfield’s sole judgment,
to affect its quality or efficiency or if the serial number has
been altered, defaced or removed. This Warranty does not
apply to a Motor-Compressor in any Unit that has been
moved from the location where it was originally installed.
The addition of methyl chloride to the condensing unit or
refrigeration system shall void this warranty.

General Conditions

Delfield shall not be liable in any manner for any default or
delay in performance hereunder caused by or resulting
from any contingency beyond Delfield’s control, including,
but not limited to, war, governmental restrictions or
restraints, strike, lockouts, injunctions, fire, flood, acts of
nature, short or reduced supply of raw materials, or
discontinuance of any part or the Motor-Compressor by
the unit manufacturer.

Replacement of a defective Motor-Compressor is limited
to one (1) Motor-Compressor by us during the four (4) year
period. Delfield shall replace the Motor-Compressor at no
charge.

This warranty does not give the Original Purchaser of the
Motor-Compressor the right to purchase a complete
replacement Motor-Compressor of the same make or of
another make. It further does not permit the replacement
to be made with a Motor-Compressor of another kind
unless authorized by Delfield. In the event Delfield
authorizes the Original Purchaser to purchase a replacement
Motor-Compressor locally, only the wholesale cost of the
Motor-Compressor is refundable.

Expressly excluded from this warranty are damages
resulting from spoilage of goods.

Except as provided in any applicable Standard One
Year Limited Warranty or applicable Service Labor
Contract, the foregoing is exclusive and in lieu of all
other warranties, whether written or oral, express or
implied. This Warranty supersedes and excludes any
prior oral or written representations or warranties.
Delfield expressly disclaims any implied warranties of
merchantability, fitness for a particular purpose or
compliance with any law, treaty, rule or regulation
relating to the Motor-Compressor, and the full liability
of Delfield for any breach of this warranty, will be as
provided in this warranty.

Other than any applicable Delfield Standard One year
Limited Warranty, this Delfield Additional Four Year
Protection Plan and any applicable Delfield Service Labor
Contract, the Original Purchaser agrees and acknowledges
that no other warranties are offered or provided in connection
with or for the Motor-Compressor or any part thereof.

In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of
penalties.

Summary of Contents for Versa Drawer 18650VDL

Page 1: ...t MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 www delfield com SERVICE MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to service this equipment MODELS F17VD84 F18VD50 F18VD82 F2984VDL F2984VDR RETAIN THIS MANUAL FOR FUTURE REFERENCE 18650VDL 18650VDR 18682VDL 18682VDR ...

Page 2: ...rt in length as possible Use refrigerant hoses SAE J196 1992 approved with a shutoff device within 12 inches of the ends Make sure recovery tanks are DOT approved for use with the type of refrigerant being serviced Service units only in well ventilated areas using mechanical ventilation systems Follow all accessory advisories and instructions Do not operate any unit with defective or damaged parts...

Page 3: ...TION 6 OPERATION 6 OPERATOR MAINTENANCE 6 COMPONENT REMOVAL AND REPLACEMENT 7 COVERS AND PANELS 7 Front Louvered Panel 7 Louvered Access End Panel 7 Rear Panel 7 DRAWER ASSEMBLY 7 Drawer Removal 7 Drawer Gasket 7 Drawer Front Assembly 7 Return Air Baffle 8 Drawer Switch 8 EVAPORATOR COIL ASSEMBLY COVER 8 EVAPORATOR COIL ASSEMBLY 9 EXPANSION VALVE 9 CONDENSER FAN BLADE 9 CONDENSER FAN MOTOR 10 COND...

Page 4: ...15 CONFIGURATION 15 DIAGNOSTICS 15 TIME AND DATE 15 SOFTWAREVERSIONS 15 TROUBLESHOOTING 16 GENERAL 16 DIAGNOSTICS 16 TROUBLESHOOTING CHART 16 CIRCUIT AND CONTROL DIAGRAMS 18 STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT 23 MANUFACTURER S LIMITED LIFETIME WARRANTY 24 STANDARD ONEYEARWARRANTY 25 ADDITIONAL FOURYEAR PROTECTION PLAN for Motor Compressor only 26 ...

Page 5: ...ce The gaskets are removable without tools This manual covers standard units If you have a custom unit consult the service department at 800 733 8829 SERIAL AND MODEL NUMBERS The serial and model numbers are located inside Drawer 1 on the left side Serial and Model Number location THAW SYSTEM Hot gas is used for the thaw cabinet operation and the defrost mode A hot gas solenoid controls the heat I...

Page 6: ...15 1 3 Right 6 0 34 50 31 5 2 520 5 15P 18682VDL 115 2 1 3 Left 12 0 34 82 31 5 4 720 5 15P 18682VDR 115 2 1 3 Right 12 0 34 82 31 5 4 720 5 15P Refrigeration System HFC 404ARefrigerant Electrical Connections 115Volt 60Hertz singlephase 3 wire grounded 8 cord with plug Drawers 32 11 12 gauge stainless steel 12 X 20 pan capacity Legs 6 adjustable Casters 5 casters with and without brakes INSTALLATI...

Page 7: ...ss end panel removal is similar for all models 1 While supporting the louvered access end panel remove mounting screws 2 Lift louvered access end panel out and up to remove 3 Reverse the above steps to install the louvered access end panel Rear Panel 1 While supporting the rear panel remove 11 screws 2 Remove the rear panel from the unit 3 Reverse the above steps to install the rear panel DRAWER A...

Page 8: ...e 5 Drawer switch Figure 5 Drawer Switch 4 Tag and disconnect the wiring harness from the drawer switch 5 Reverse the above steps to install a replacement drawer switch EVAPORATOR COIL ASSEMBLY COVER NOTE Evaporator coil assembly cover removal is similar for all models 1 The evaporator coil assembly cover is mounted behind the drawer Figure 6 2 Reach inside the box and remove four screws from the ...

Page 9: ...sembly Recharge the system as described in the EPA guidelines for RECOVERY PURGING TESTING AND RECHARGING REFRIGERATION UNIT EXPANSION VALVE 1 Disconnect power from the refrigeration unit 2 Remove the evaporator coil assembly cover as described in COVERS AND PANELS 3 Remove the expansion valve thermocouple from the evaporator line Screw Evaporator coil assembly Expansion valve TXV Thermocouple Fig...

Page 10: ...ont louvered panel The removal procedure is similar for all models 3 Refer to the EPA guidelines for RECOVERY PURGING TESTING AND RECHARGING REFRIGERATION UNIT to recover the refrigerant from the refrigeration system 4 Remove the louvered access end panel as described in COVERS AND PANELS 5 Tagandremovethetemperaturesensorfromthe condensercoil 6 Remove six screws securing the condenser coil inside...

Page 11: ...latortotherefrigerationunit 7 Remove the accumulator from the unit 8 Reverse the above steps to install a replacement accumulator FILTER DRYER 1 Disconnect power from the refrigeration unit 2 Remove the louvered access end panel as described in COVERS AND PANELS 3 Refer to the EPA guidelines for RECOVERY PURGING TESTING AND RECHARGING REFRIGERATION UNIT to recover the refrigerant from the refriger...

Page 12: ...nd remove the temperature sensor mounting screw Figure 14 Rear panel Box temperature sensor Temperature sensor mounting screw Figure 14 Box Temperature Sensor 5 Tag and disconnect the wiring harness from the box temperature sensor 6 Remove the temperature sensor mounting screw and remove the box temperature sensor from the rear 7 Reverse the above steps to install a replacement box temperature sen...

Page 13: ... can make the unit unstable 1 Place a jack underneath the refrigeration unit as close as possible to the leg Figure 16 Lift the unit just high enough to remove the leg from underneath the refrigeration unit Place blocking underneath the unit to prevent the unit from falling during removal of the leg 2 Remove four screws from the upper portion of the leg 3 Remove the leg from the refrigeration unit...

Page 14: ...Narrowstothedesiredmode Refrigerate Freeze Chill orThaw Figure20 NOTE The desired mode will display with parenthesis when selected 3 Press the drawer tab again to lock the desired mode setting Figure 20 Drawer Mode Display 2 Drawer Display shown CAUTION Only qualified technicians should access the following programmingmenus MANUAL DEFROST NOTE Both buttons must be pressed within one second to manu...

Page 15: ...runtimes System Drawer open timeout data log interval run frame heaters metric language reload defaults 2 Press i Enter to lock in an adjusted setting or press the LEFT arrow to go back DIAGNOSTICS OnceintheProgramMenupresstheUPorDOWNarrows to Diagnostics and press i Enter for diagnostics display Figure24 Drawer Drawer 3 4 Figure 24 Diagnostics Menu 4 Drawer Display Shown TIME AND DATE OnceinthePr...

Page 16: ... the control is calling for the fans to run Check the temperature sensor in the condenser coil to see if it is open or shorted Unit is not reaching desired Check to see that the unit is in the correct mode of operation temperature Check to see that the unit is set at the desired set point Check to see if the box temperature sensor is open or shorted Listen to determine if the compressor is cycling...

Page 17: ...the condensate drain pan Make sure the condensate wicks are not missing Water inside the unit Check the evaporator drain pan and drain lines Verify proper condensate removal Verify proper condensate pan installation Unit is showing Drawer Open Closedrawer on the display Check drawer switch Check control Unit is showing Out of Check to determine that the unit is in the correct mode of operation Tem...

Page 18: ...E CONTROL COND TEMP SENSOR COND COIL COND OUTLET TEMP SENSOR ACCESS PORT FILTER DRYER RECEIVER REFG SOL S HOT GAS SOL S REFG SOL S HOT GAS SOL S TXV 2 12V DC AXIAL FANS EVAP COIL REFG BOX 2 BOX TEMP SENSOR DEFROST TEMP SENSOR TXV 2 12V DC AXIAL FANS EVAP COIL REFG BOX 1 BOX TEMP SENSOR DEFROST TEMP SENSOR ACCESS PORT PRESSURE TRANSDUCER ACCUMULATOR COMPRESSOR 1 3 HP ...

Page 19: ...ID 4 D4 HOT GAS SOLENOID J27 1 D1 REFG SOLENOID 2 D1 HOT GAS SOLENOID 3 D2 REFG SOLENOID 4 D2 HOT GAS SOLENOID J29 1 D1 FRAME HEATER 2 NC 3 D2 FRAME HEATER 1 COMMON FOR D1 AND D2 DRW SWITCHES 2 D1 SWITCH 3 D2 SWITCH 4 COMMON FOR D3 AND D4 DOOR SWITCHES 5 D3 SWITCH 6 D4 SWITCH 1 12V FOR D1 AND D2 FANS 2 D1 FANS RETURN 3 D2 FANS RETURN 4 12V FOR D3 AND D4 FANS 5 D3 FANS RETURN 6 D4 FANS RETURN J30 1...

Page 20: ...MP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC H OT 24 26 J33 J25 J32 1 2 COND F AN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC MTR 35 HE ATER SWI T CH 12 VDC DRAWER LIMIT EVAP F ANS 7 1 2 MTR MTR 8 34 DRAWER F R AME PROBE PROBE EVAP TEM P BOX TEM P 1 3 MTR DRAWER LIMIT DRAWER F R AME EVAP TEM P EVAP F ANS 12 VDC SWI T CH 7 MTR 9 HE ATER PROBE PROBE BOX TEM P 4 MTR 10 9 1 8 7 1112 J31 1 34 J...

Page 21: ... VALVES 1 1 J30 J28 J27 1 J19 J18 1 J23 J29 J22 4 1 1 J31 1 DRAWER 2 DRAWER 1 DRAWER 4 DRAWER 3 I O BOARD BOARD CONNECTOR MAP COMMUNICATION CABLE TO DISPLAY BOARD I O TO DISP 1 TO 1 2 TO 2 3 TO 3 PREFER SHIELDED TWISTED PAIR 1 AND 2 TWISTED 3 SHIELD POWER TO DISPLAY BOARD 1 8V 2 GROUND I O TO DISP 1 TO 1 2 TO 2 TEMPERATURE SENSORS SUCTION PRESSURE TRANSDUCER 1 5V 2 SIGNAL 3 COMMON 85 265 VAC 50 60...

Page 22: ...D POWER TO I O BOARD 1 8V 2 GROUND DISP TO I O 1 TO 1 2 TO 2 I O BOARD SEE BOARD CONNECTOR FOR PIN CONNECTION DETAILS COMMUNICATION CABLE TO I O BOARD DISP TO I O 1 TO 1 2 TO 2 3 TO 3 PREFER SHIELDED TWISTED PAIR 1 AND 2 TWISTED 3 SHIELD CONTROL POWER L1 G N BOX 2 BOX 1 ...

Page 23: ...NAL 3 COMMON 85 265 VAC 50 60 HZ CONTROL POWER J25 AC HOT FOR ALL AC LOADS J28 1 D3 REFG SOLENOID 2 D3 HOT GAS SOLENOID 3 D4 REFG SOLENOID 4 D4 HOT GAS SOLENOID J27 1 D1 REFG SOLENOID 2 D1 HOT GAS SOLENOID 3 D2 REFG SOLENOID 4 D2 HOT GAS SOLENOID J29 1 D1 FRAME HEATER 2 NC 3 D2 FRAME HEATER 1 COMMON FOR D1 AND D2 DRW SWITCHES 2 D1 SWITCH 3 D2 SWITCH 4 COMMON FOR D3 AND D4 DOOR SWITCHES 5 D3 SWITCH...

Page 24: ...nless pre approvedwithaServiceWorkAuthorizationfromDelfield You must submit the number with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Solenoid Coil Hi limit Thermal Protector Switch Compressor Start Components and Overload Protector Evaporator Condenser Fan Motor and Blade Door Hinges Locks and Gaskets LABOR OF 2 HOURS TO REPLACE DrawerTracks Cartridges Pressure Control Microprocesso...

Page 25: ...r repair kits must be made through a Delfield Parts Depot or an authorized Delfielddealer Thedefectivepartinvoicemustbereturned to Delfield within 15 days after the date of service to be eligibleforwarrantycoverage Allclaimsmustincludethe model serial number an original date of installation and customer identification Use of parts other than original Delfield replacement parts will not be covered ...

Page 26: ...SIDER CUSTOMER MAY INITIATEASERVICEAGREEMENTWITHOUTPARTSCOVERAGE Ifshipmentofareplacementpartisrequestedpriortothearrivalinthe Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued after the part has been received and inspectedatDelfield splantanddeterminedbyDelfieldtobewithinthis warranty ...

Page 27: ...s beenaltered defacedorremoved ThisWarrantydoesnot apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty GeneralConditions Delfieldshallnotbeliableinanymannerforanydefaultor delay in performance hereunder caused by or resulting fromanycon...

Page 28: ...800 733 8829 Model ______________________ S N _____________________ InstallationDate ______________ For a list of Delfield s authorized parts depots visit our website at www delfield com 980 S Isabella Rd Mt Pleasant MI 48858 U S A 989 773 7981 or 800 733 8829 Fax 989 773 3210 www delfield com Delfield reserves the right to make changes in design or specifications without prior notice 2007 The Del...

Reviews: