Delitek Waste Compactors – user -/service manual-rev 1.2
DT-200i “Green Ship” Waste Compactor – standard versions 5
Figure 2. Dimension sketch DT-200i, bottom view of mounting brackets (centre).
WARNING!
In order to avoid possible damages on equipment and personnel, extra containers onboard must
at all times be secured. The C-200 containers are designed so that they will not be able to freely
roll, as long as they are parked. However, if stored on open deck: the containers must at all
times be properly secured with straps or other suitable devices.
1.2 Connection to electric supply
Connection of el-supply must de done by a qualified electrician.
Be sure to check that the voltage specified for the waste compactor complies with the el-supply
at site. Check the voltage specification on the compactors nameplate and on the attached
Factory Acceptance Test sheet.
Note:
guide tubes, nipples, bushings, gaskets and sealing on the el-locker should be
inspected during installation. This equipment must also be checked during maintenance and
function tests of the compactor. Check for damages on door gasket or water leakages into the
el-locker. The el-locker must always be closed (except from maintenance purposes).
1.3 Checking phase/el-motor direction of rotation
Figure 3. Connection terminals
Figure 4. Direction of rotation