Delitek Waste Compactors – user -/service manual-rev 1.2
DT-200i “Green Ship” Waste Compactor – standard versions 7
a) If the input voltage is 380~440V (480V), the el-supply for the el-panel must be
taken from/ connected to the 220V output at the top of the transformer. The
jumpers on the el-motor must be set for ”Y” STAR (440V) configuration
according to paragraph 1.
b) If the input voltage is 220V, the transformer must be bypassed. Fig. 6 shows a
bypassed transformer. The el supply to the el-panel is parallel connected to the
input el-supply. I.e the voltage is not passing through the transformer at all. The
jumpers on the el-motor must be configured for ”
∆
” Delta (220V) configuration
according to paragraph 1.
.
3. When the reconfiguring of the el-system is completed, please connect the waste
compactor to the selected el-supply.
See also chapter 5 for connection diagrams and schematics regarding rewiring.
WARNING!
THIS PROCEDURE IS NOT POSSIBLE TO PERFORM FOR COMPACTORS
DELIVERED WITH 660~690V motors.