Figure 31 Slide the system into the cabinet
Connect the I/O cables and power cords
This procedure is used to connect the peripherals and power to the system.
Procedure
1. Using the connection information recorded on the labels, connect the I/O cables to the
system.
2. Plug the power cords into the power supplies.
Verifying successful DIMM replacement from the ACM
After a DIMM is replaced and power has been re-applied, you can run the FRU command line
verification from the ACM to ensure that the replacement was successful.
Procedure
1. From the ACM, type the following command:
# showfru dimm
The screen displays that the system is collecting data. When the data collection is
completed, the screen displays status information for the DIMMs.
acme-dp4400-ACM:~ # showfru dimm
Collecting Data............
________________________________________________________________
| ID| Status| Manufacturer| Part# | Serial# | Size |
|===============================================================|
| A1| OK | Samsung | M393A4K40BB2-CTD| 364BB912| 32768 MB|
| A2| OK | Samsung | M393A4K40BB2-CTD| 364B9A1B| 32768 MB| *
| A3| OK | Samsung | M393A4K40BB2-CTD| 364BA009| 32768 MB|
| A4| OK | Samsung | M393A4K40BB2-CTD| 36324964| 32768 MB|
| B1| OK | Samsung | M393A4K40BB2-CTD| 36324B7D| 32768 MB|
| B2| OK | Samsung | M393A4K40BB2-CTD| 3632553D| 32768 MB|
| B3| OK | Samsung | M393A4K40BB2-CTD| 36325451| 32768 MB|
| B4| OK | Samsung | M393A4K40BB2-CTD| 36324988| 32768 MB|
Remove and replace assemblies
46
Dell EMC Integrated Data Protection Appliance DP4400 Service Procedures