Chapter 1: Dell EMC PowerEdge MX Platform Overview
15
Dell EMC PowerEdge MX
Networking Architecture Guide
Figure 13. Dell EMC Networking MXG610s Fibre Channel switch module
The following MXG610s components are labeled in Figure 13:
1.
Express service tag
2.
Module insertion/removal latch
3.
Micro-B USB console port
4.
Power and indicator LEDs
5.
Eight 32Gb FC SFP ports
6.
Two 4x 32Gb FC QSFP ports
The Dell EMC PowerEdge MX5000s SAS module supports x4 SAS internal connections
to all eight front-facing slots in the PowerEdge MX7000 chassis. The MX5000s uses T10
SAS zoning to provide multiple SAS zones/domains for the compute sleds. Storage
management is conducted through the OEM-M console.
The MX5000s provides Fabric C SAS connectivity to each compute and one or more
MX5016s storage sleds. Compute sleds connect to the MX5000s using either SAS Host
Bus Adapters (HBA) or a PowerEdge Raid Controller (PERC) in the mini-mezzanine PCI-
e slot.
The MX5000s switches are deployed as redundant pairs to offer multiple SAS paths to the
individual SAS disk drives. An MX7000 chassis supports redundant MX5000s in Fabric C.
Note:
A PowerEdge MX5000s SAS module and a MXG610s is not supported in the same
MX7000 chassis.
Dell EMC
PowerEdge
MX5000s SAS
module