Chapter 4: PowerEdge MX Ethernet Switch Operating Modes
41
Dell EMC PowerEdge MX
Networking Architecture Guide
Figure 30. Two MX5108n in a single chassis topology
Note:
A SmartFabric using the MX5108n cannot span multiple MX7000 chassis
SmartFabric uplink topologies
This section outlines the supported SmartFabric topologies.
Figure 31
shows the wiring topology in an Ethernet only environment. The MX9116n FSE
pair and the leaf pair are each configured for VLT. Uplinks are shown in green, with both
links from each MX9116n FSE in a VLT port channel. In addition to the uplinks shown, if
extra uplink bandwidth is needed, the QSFP28-DD port groups can be used as uplinks by
changing the breakout type and cabling as described in Section 3.2.1.
Note
: See Appendix A for information about connecting to the Dell EMC Networking Z9100-ON
ToR switch.
MX9116n FSE
–
Ethernet only