Chapter 4: PowerEdge MX Ethernet Switch Operating Modes
48
Dell EMC PowerEdge MX
Networking Architecture Guide
When the VLAN is deployed through a server template, the SmartFabric Services update
all participating switches with a QoS class map. This class map uses VLAN ID
classification. A QoS policy map and then assigns all traffic matching the class map to the
appropriate data queue.
Note
: For more information about QoS, see the OS10EE Enterprise Edition Users Guide.
Because SmartFabric mode provides network automation capabilities that Full Switch
mode does not, the number of recommended VLANs differs between the modes. Table 5
provides the recommended maximum number of VLANs per fabric, uplink, and server
port.
Table 5.
SmartFabric VLAN scaling guidelines
OS10EE Version
Parameter
Value
10.4.0E(R3S)
Recommended max VLANs per fabric
128
Recommended max VLANs per uplink
128
Recommended max VLANs per server port
32
Note
: These maximums are considered a best practice, not an enforced limit.
VLAN scaling
guidelines