mtu 9216
!
interface ethernet1/1/7
no shutdown
fec off
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 96,1611-1614,2711-2712
mtu 9216
!
interface ethernet1/1/8
no shutdown
fec off
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 96,1611-1614,2711-2712
mtu 9216
!
interface ethernet1/1/9
description VLTi
no shutdown
no switchport
mtu 9216
!
interface ethernet1/1/10:1
description VLTi
no shutdown
no switchport
mtu 9216
!
interface ethernet1/1/11
no shutdown
channel-group 1 mode active
no switchport
mtu 9216
!
interface ethernet1/1/12
no shutdown
switchport access vlan 1
!
interface ethernet1/1/13
no shutdown
switchport access vlan 1
!
interface ethernet1/1/14
no shutdown
switchport access vlan 1
!
interface ethernet1/1/15
no shutdown
switchport access vlan 1
!
interface mgmt1/1/1
no shutdown
!
system qos
service-policy input type qos PM_VLAN
!
support-assist
!
policy-map type application policy-iscsi
!
policy-map type qos PM_VLAN
!
class CM1
set qos-group 2
!
class-map type application class-iscsi
!
52
Manual switch configuration
Summary of Contents for PowerEdge MX7000
Page 1: ...Dell EMC VMware Cloud Foundation for PowerEdge MX7000 Deployment Guide ...
Page 8: ...Figure 1 Cloud Foundation deployment workflow 8 Overview ...
Page 27: ...Figure 19 Dual PowerEdge MX7000 enclosure configuration Physical layout 27 ...
Page 29: ...Figure 20 MX9002m Management module cabling Physical layout 29 ...
Page 30: ...Figure 21 Connectivity between FSE modules and FEM modules 30 Physical layout ...
Page 31: ...Figure 22 Uplinks to customer network environment Physical layout 31 ...
Page 42: ...Figure 25 MX9002m Management Module cabling 42 Networking requirements ...
Page 43: ...Figure 26 Connectivity between FSE modules and FEM modules Networking requirements 43 ...
Page 44: ...Figure 27 Uplinks to customer network environment 44 Networking requirements ...