background image

45

4

Whispering, open office layout, normal living room

35

2

Quiet office

30

1

Quiet library

20

0

Recording studio

41

Summary of Contents for PowerEdge R7425

Page 1: ...torage capacity for low latency data intensive workloads The following documentation is designed as both instructional aid and online reference material for the PowerEdge R7425 rack server The material introduces new technologies and features specific to the PowerEdge R7425 in an effort to better prepare technicians to provide outstanding support to our customers Technical Guide ...

Page 2: ...amage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death 2018 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2017 12 Rev A00 ...

Page 3: ...9 NIC indicator codes 21 Power supply unit indicator codes 21 Drive indicator codes 23 LCD panel 24 Inside the system 25 4 Processors 27 Processor features 27 Supported processors 27 Processor configurations 27 5 System memory 28 General memory module installation guidelines 30 Memory Configurations 30 Memory RAS features 30 6 Storage 32 Storage Controllers 32 Supported drives 32 IDSDM with vFlash...

Page 4: ...OpenManage systems management 53 iDRAC with Lifecycle controller 54 iDRAC features and comparison 54 Dell EMC consoles 59 Dell EMC OpenManage systems management tools utilities and protocols 60 Integration with third party consoles 62 OpenManage connections with third party consoles 62 12 Appendix A Additional specifications 64 PSU specifications 64 System dimensions 65 Chassis weight 66 Environme...

Page 5: ...ProSupport Flex for Data Center 71 Additional professional services 71 Dell EMC Education Services 71 Dell EMC Global Infrastructure Consulting Services 72 Dell EMC managed services 72 5 ...

Page 6: ...Ie 3 0 enabled expansion slots and a choice of network interface technologies to cover NIC and rNDC Product positioning The PowerEdge R7425 is a general purpose platform with highly expandable memory and impressive I O capability to match The R7425 is capable of handling demanding workloads and applications targets to support data warehouses E commerce databases and high performance computing HPC ...

Page 7: ...ting and downtime with embedded diagnostic and automated case creation Supports complete lifecycle management with the OpenManage portfolio of systems management solutions including leading remote management with iDRAC9 and Lifecycle Controller New technologies The following are the new technologies featured on the PowerEdge R7425 Table 1 New technologies New technology Detailed description AMD Na...

Page 8: ...nd alerting data center level power monitoring and faster performance For details see the Dell EMC OpenManage systems management section LCD bezel The PowerEdge R7425 LCD control panel is embedded in an optional front bezel for easy access and management Wireless Management The Quick Sync 2 BLE WiFi module offers secure wireless access to the embedded iDRAC SupportAssist Collections remote RACADM ...

Page 9: ...M LRDIMM 12x NVDIMM N Disk drives 3 5 2 5 12Gb SAS 6Gb SATA 3 5 2 5 12Gb SAS 6Gb SATA RAID controllers Adapters H330 H730P H740P H840 SW RAID is not supported Adapters H330 H730P H740P H840 Mini Mono HBA330 H330 H730P H740P SW RAID S140 HBA HBA330 12 G SAS HBA HBA330 12G SAS HBA PCIe SSD Up to 24x PCIe SSD Up to 12x PCIe SSD with common slot 4x per PCIe ext card PCIe slots Max 8 x PCIe 3 0 Max 8 x...

Page 10: ...drive tray and 3 5 inch x2 SAS SATA backplane back or 3 5 inch x12 SAS SATA backplane 3 5 inch x4 SAS SATA backplane on the mid drive tray and 2 5 inch x4 SAS SATA backplane back or 2 5 inch x24 NVMe backplane Power supply 2400 W AC Platinum 2000W AC Platinum 1600W AC Platinum 1100W AC and 380V DC Mixed Mode Platinum 1100W AC Platinum 1100W 48V DC Gold 750W AC Platinum 750W AC Titanium 750W AC and...

Page 11: ...GB 2 x 1GB 2x 10GB RJ45 or 2 x 1GB 2x 10GB SFP Power supply 495W AC 750W AC 1100W AC 1600W AC 2000W AC 1100W DC 750W and 1100W AC DC mixed mode Supported operating systems Windows Server 2016 with Nano N version Windows Server 2012 R2 N 1 version RHEL 7 4 N version RHEL 6 9 N 1 version SLES 12 SP3 N version Ubuntu 16 04 Virtualization options VMware vSphere 2016 U1 ESXi 6 5 U1 N version VMware vSp...

Page 12: ...os Core and Nagios XI Dimensions and weight Height 86 80mm 3 41 inches Width 482 0mm 18 98 inches Depth with bezel 751 47 mm 29 58 inches Depth without bezel 737 63 mm 29 04 inches Recommended support Dell ProSupport Plus for critical systems or Dell ProSupport for premium hardware and software support for your PowerEdge solution Consulting and deployment offerings are also available Contact your ...

Page 13: ...to 11 up to four 3 5 inch SAS SATA or Nearline SAS mid drives in slots 14 to 17 and up to two 3 5 inch SAS SATA or Nearline SAS rear accessible drives in slots 12 to 13 24 drives system Up to 24 2 5 inch SAS SATA or Nearline SAS front accessible drives in slots 0 to 23 24 drives system Up to 24 2 5 inch NVMe front accessible drives in slots 0 to 23 32 drives system Up to 24 2 5 inch SAS SATA or Ne...

Page 14: ...ins the power button VGA port iDRAC Direct micro USB port and two USB 2 0 ports 4 Information tag N A The Information Tag is a slide out label panel that contains system information such as Service Tag NIC MAC address and so on If you have opted for the secure default access to iDRAC the Information tag also contains the iDRAC secure default password 5 Optical drive optional N A Enables you to ret...

Page 15: ...using mobile devices This feature aggregates hardware firmware inventory and various system level diagnostic error information that can be used in troubleshooting the system You can access system inventory Dell Lifecycle Controller logs or system logs system health status and also configure iDRAC BIOS and networking parameters You can also launch the virtual Keyboard Video and Mouse KVM viewer and...

Page 16: ...memory error occurs Check the System Event Log or system messages for the location of the failed memory Reseat the memory module PCIe indicator The indicator turns solid amber if a PCIe card experiences an error Restart the system Update any required drivers for the PCIe card Reinstall the card System health and system ID indicator codes The system health and system ID indicator is located on the ...

Page 17: ...ate Press the iDRAC Quick Sync 2 button to turn off If the LED fails to turn off restart the system Blinks white rapidly Indicates data transfer activity N A Blinks white slowly Indicates that firmware update is in progress N A Blinks white five times rapidly and then turns off Indicates that the iDRAC Quick Sync 2 feature is disabled Check if iDRAC Quick Sync 2 feature is configured to be disable...

Page 18: ...ou to access the iDRAC Direct features For more information see the iDRAC User s Guide at Dell com idracmanuals 4 iDRAC Direct LED N A The iDRAC Direct LED indicator lights up to indicate that the iDRAC Direct port is connected 5 VGA port Enables you to connect a display device to the system iDRAC Direct LED indicator codes The iDRAC Direct LED indicator lights up to indicate that the port is conn...

Page 19: ...connected Flashing green on for two seconds and off for two seconds Indicates that the laptop or tablet connected is recognized Turns off Indicates that the laptop or tablet is unplugged Back view of the system Figure 12 Back view of three riser system Figure 13 Back view of 4 x 2 5 inch drive system Figure 14 Back view of 2 x 3 5 inch drive system 19 ...

Page 20: ... information about the supported configurations see the see the Technical specifications section 8 USB port 2 The USB ports are 9 pin and 3 0 compliant These ports enable you to connect USB devices to the system 9 VGA port Enables you to connect a display device to the system For more information see the see the Technical specifications section 10 Serial port Enables you to connect a serial device...

Page 21: ...eing sent or received Link indicator is green and activity indicator is off The NIC is connected to a valid network at its maximum port speed and data is not being sent or received Link indicator is amber and activity indicator is off The NIC is connected to a valid network at less than its maximum port speed and data is not being sent or received Link indicator is blinking green and activity is o...

Page 22: ... turn the system on CAUTION When correcting a PSU mismatch replace only the PSU with the blinking indicator Swapping the PSU to make a matched pair can result in an error condition and unexpected system shutdown To change from a high output configuration to a low output configuration or vice versa you must turn off the system CAUTION AC PSUs support both 240 V and 120 V input voltages with the exc...

Page 23: ...tion or vice versa you must turn off the system CAUTION If two PSUs are used they must be of the same type and have the same maximum output power CAUTION Combining AC and DC PSUs is not supported and triggers a mismatch Drive indicator codes Each drive carrier has an activity LED indicator and a status LED indicator The indicators provide information about the current status of the drive The activ...

Page 24: ...e LCD panel are outlined here The LCD backlight is white during normal operating conditions When the system needs attention the LCD backlight turns amber and displays an error code followed by descriptive text NOTE If the system is connected to a power source and an error is detected the LCD turns amber regardless of whether the system is turned on or off When the system turns off and there are no...

Page 25: ...m information status and error messages or iDRAC IP address Inside the system Figure 20 Inside the system Configuration showing air shroud 1 backplane 2 backplane expander 3 cooling fan 6 in the cooling fan assembly 4 air shroud 5 network daughter card 6 riser 1 25 ...

Page 26: ...ay and rear drive cage 1 backplane 2 backplane expander 3 cooling fan 6 in the cooling fan assembly 4 drive 4 in the mid drive tray 5 mid drive backplane 6 rear drive backplane 7 drive 2 x 3 5 inch or 4 x 2 5 inch in the rear drive cage 8 system board 9 riser 1 26 ...

Page 27: ...on Chip Soc design with support for two high performance threads per core 14nm process technology Industry leading memory bandwidth 8 channels of memory The single socket system supports up to 16 DIMMs of DDR4 delivering up to 64 or 128 GB memory capacity Maximum DIMM memory capacity of 128 GB will be available at a later time The processor is a complete SoC with fully integrated high speed I O su...

Page 28: ...r 2133 MT s depending on the following factors DIMM type RDIMM or LRDIMM Number of DIMM slots populated per channel System profile selected for example Performance Optimized or Custom can be run at high speed or lower Maximum supported DIMM frequency of the processors Your system contains 32 memory sockets split into two sets of 16 sockets one set per processor Each 16 socket set is organized into...

Page 29: ...nnel 3 Channel 4 Channel 5 Channel 6 Channel 7 Proc esso r 1 Slots A5 and A13 Slots A6 and A14 Slots A7 and A15 Slots A8 and A16 Slots A1 and A9 Slots A2 and A10 Slots A3 and A11 Slots A3 and A11 Proc esso r 2 Slots B5 and B13 Slots B6 and B14 Slots B7 and B15 Slots B8 and B16 Slots B1 and B9 Slots B2 and B10 Slots B3 and B11 Slots B4 and B12 29 ...

Page 30: ...iability availability and serviceability RAS features help keep the system online and operational without significant impact to performance and can decrease data loss and crashing due to errors RAS aids in rapid accurate diagnosis of faults which require service Table 20 Supported RAS features Feature Description Dense configuration optimized profile Increased memory reliability can be a result fr...

Page 31: ... correctable errors occur in a rank or channel they are moved to the spare area while the operating system is running to prevent the errors from causing an uncorrectable failure Memory thermal throttling This feature helps to optimize power performance and can also be used to prevent DIMMs from overheating 31 ...

Page 32: ...ware controller without consuming a PCIe slot by using a small form factor and high density connector to the base planar The new PERC controller offerings will leverage heavily on previous generation PERC family The premium performance PERC series controller will drive better IOPs and enhanced the SSD performance Table 21 PERC series controller offerings Performance level Controller and descriptio...

Page 33: ...3 0 interface as the host In 14 Gen servers the IDSDM and vFlash card features microSD in place of an SD card The supported capacities for the IDSDM microSD cards are 16 32 64 GB while for vFlash the capacity is limited to 16 GB only The write protect switch is built on the IDSDM with vFlash module Optical Drives The PowerEdge R7425 supports one of the following internal optical drive options DVD ...

Page 34: ...t to draw power and provide system management bus sideband access into the BOSS s thermal field replacement unit TFRU The TFRU controls BOSS s localized active cooling fan solution and provide status to iDRAC SATA data is exposed via the NPIO connector that is cabled to the system board or backplane Figure 23 Boot Optimized Storage Subsystem BOSS Table 23 BOSS RAID controller features Function Fea...

Page 35: ...No NOTE No controller cache Battery support N A NOTE No battery Non RAID disk cache policy Yes NOTE OS controlled Device defaults SMART Info Yes NOTE Can be pulled by Marvell CLI Physical disk hot swap No Virtual disk expansion No Virtual disk slicing No Virtual disk migration Yes NOTE On new controller virtual disk must be Imported from HII before presented to OS Split mirror No NOTE System requi...

Page 36: ... UNMAP virtual disk No TRIM and UNMAP Non RAID physical disk Yes Self encrypting drives SED support No Cryptographic erase sanitize Yes NOTE If drive supports SANITIZE Crypto Erase No other encryption support from controller or drive 36 ...

Page 37: ...Ie Expansion cards The Dell EMC PowerEdge R7425 system supports up to eight PCI express PCIe generation 3 expansion cards slots The list below shows the available PCIe slots for R7425 1 Riser 1 RSR 1A Slot 1 with PCIe Gen3 x16 lanes from CPU1 and Slot 3 with PCIe Gen3 x16 lanes from CPU1 RSR 1D Slot 1 with PCIe Gen3 x16 lanes from CPU1 Slot 2 with PCIe Gen3 x8 lanes and Slot 3 with PCIe Gen3 x8 la...

Page 38: ... Platform Assurance feature in Windows Server 2016 is supported TPM can also be used to enable the BitLocker hard drive encryption feature in Windows Server 2012 2016 The TPM chip is on the Plug in Module PIM and bound only to one system board The system board has a connector for the plug in module and it is factory installed There are four types of TPM module options No TPM TPM 1 2 Nuvoton FIPS C...

Page 39: ...structure Planning Tool EIPT is a tool that helps you plan and tune your computer and infrastructure equipment for maximum efficiency by calculating hardware power consumption power infrastructure and storage Learn more at Dell com calc Power monitoring accuracy PSU power monitoring improvements include Power monitoring accuracy of 1 whereas the industry standard is 5 More accurate reporting of po...

Page 40: ...rives Open and closed loop fan speed control Open loop fan control uses system configuration to determine fan speed based on system inlet air temperature Closed loop thermal control uses temperature feedback to dynamically adjust fan speeds based on system activity and cooling requirements User configurable settings With the understanding and realization that every customer has a unique set of cir...

Page 41: ...45 4 Whispering open office layout normal living room 35 2 Quiet office 30 1 Quiet library 20 0 Recording studio 41 ...

Page 42: ...mpliant square or unthreaded round hole 4 post racks including all generations of the Dell racks Support for tooled installation in 19 EIA 310 E compliant threaded hole 4 post racks Support full extension of the system out of the rack to allow serviceability of key internal components Support for optional cable management arm CMA Minimum rail mounting depth without the CMA 714 mm Minimum rail moun...

Page 43: ...tic rails The static rails support a wider variety of racks than the sliding rails However they do not support serviceability in the rack and are thus not compatible with the CMA Figure 25 Static rails Static rails features summary Static Rails for 4 post 2 post Racks Supports Stab in installation of the chassis to the rails Support tool less installation in 19 EIA 310 E compliant square or unthre...

Page 44: ...rails B13 or the ReadyRails Static rail B4 must be selected NOTE ReadyRails Sliding rails B6 are drop in only Table 26 Static Sliding or Stab in Drop in sliding rails Rail identifier Rail type Installatio n method Supported rack types Dell EMC Titan or Titan D Racks 4 Post 2 Post Square Round Thread Flush Center B6 Ready Rails Sliding Drop in X X X B13 Stab in Drop in Sliding Stab in Drop in X X B...

Page 45: ...ack in which they are being mounted The Min Max values listed above represent the allowable distance between the front and rear mounting flanges in the rack Rail depth without the CMA represents the minimum depth of the rail with the outer CMA brackets removed if applicable as measured from the front mounting flanges of the rack Cable management arm CMA The optional cable management arm CMA organi...

Page 46: ... installation is to first insert the rear standoffs on the system into the rear J slots on the rails to free up a hand and then rotate the system down into the remaining J slots while using the free hand to hold the rail against the side of the system A stab in design means that the inner chassis rail members must first be attached to the sides of the system and then inserted into the outer cabine...

Page 47: ...the rear rail standoff on each side of the system and lower them into the rear J slots on the slide assemblies 3 Rotate the system downward until all the rail standoffs are seated in the J slots Figure 29 Rail standoffs seated in J slots 47 ...

Page 48: ...system into the rack until the system is in the rack Figure 30 Slide system into the rack Installing the system into the rack option B Stab In 1 Pull the intermediate rails out of the rack until they lock into place 2 Release the inner rail lock by pulling forward on the white tabs and sliding the inner rail out of the intermediate rails 48 ...

Page 49: ... Rail component Number Component 1 Intermediate rail 2 Inner rail 3 Attach the inner rails to the sides of the system by aligning the J slots on the rail with the standoffs on the system and sliding forward on the system until they lock into place 49 ...

Page 50: ...Figure 32 Attach the inner rails to the system 4 With the intermediate rails extended install the system into the extended rails 50 ...

Page 51: ...Figure 33 Install system into the extended rails 5 Pull the blue slide release lock tabs forward on both the rails and slide the system into the rack 51 ...

Page 52: ...Figure 34 Slide system into the rack 52 ...

Page 53: ...nsoles OpenManage systems management solutions consist of a combination of embedded management features and software products that help you automate and simplify the entire server lifecycle deploy update monitor and maintain OpenManage solutions are innovatively designed for simplicity and ease of use to help you reduce complexity save time achieve efficiency control costs and empower productivity...

Page 54: ...xpress for Blades iDRAC9 Express for Blades iDRAC8 Enterprise iDRAC9 Enterprise Interface Standards Redfish Yes Yes Yes Yes Yes Yes Yes Yes IPMI 2 0 Yes Yes Yes Yes Yes Yes Yes Yes DCMI 1 5 Yes Yes Yes Yes Yes Yes Yes Yes Web based GUI Yes Yes Yes Yes Yes Yes Yes Yes Racadm command line local remote Yes Yes Yes Yes Yes Yes Yes Yes SMASH CLP SSH only Yes Yes Yes Yes Yes Yes Yes Yes Telnet Yes Yes Y...

Page 55: ...es Yes PK authentication No No Yes Yes Yes Yes Yes Yes FIPS 140 2 Yes Yes Yes Yes Yes Yes Yes Yes Secure UEFI boot certificate management No Yes No Yes No Yes No Yes Lock down mode No No No No No No Yes Unique iDRAC default password No Yes No Yes No Yes No Yes Customizable Security Policy Banner login page No Yes No Yes No Yes No Yes Quick Sync 2 0 optional auth for read operations No Yes No Yes N...

Page 56: ...s Yes Yes Yes Yes Yes Power capping No No No No No No Yes Yes Power Center integration No No No No No No Yes Yes Temperature monitoring Yes Yes Yes Yes Yes Yes Yes Yes Temperature graphing No No Yes Yes Yes Yes Yes Yes Health Monitoring Predictive failure monitoring Yes Yes Yes Yes Yes Yes Yes Yes SNMPv1 v2 and v3 traps and gets Yes Yes Yes Yes Yes Yes Yes Yes Email alerting No No Yes Yes Yes Yes ...

Page 57: ...Yes Yes Yes Yes Yes Yes Yes Yes AutoDiscovery No No Yes Yes Yes Yes Yes Yes Remote OS deployment No No Yes Yes Yes Yes Yes Yes Embedded driver pack Yes Yes Yes Yes Yes Yes Yes Yes Full configuration inventory Yes Yes Yes Yes Yes Yes Yes Yes Inventory export Yes Yes Yes Yes Yes Yes Yes Yes Remote configuration Yes Yes Yes Yes Yes Yes Yes Yes Zerotouch configuration No No No No No No Yes Yes System ...

Page 58: ...deo capture No No No No No No Yes Yes Boot capture No No No No No No Yes Yes Manual reset for iDRAC LCD ID button Yes Yes Yes Yes Yes Yes Yes Yes Remote reset for iDRAC requires iSM Yes Yes Yes Yes Yes Yes Yes Yes Virtual NMI Yes Yes Yes Yes Yes Yes Yes Yes OS watchdog Yes Yes Yes Yes Yes Yes Yes Yes SupportAssist Report embedded Yes Yes Yes Yes Yes Yes Yes Yes System Event Log Yes Yes Yes Yes Yes...

Page 59: ...t securely to Dell technical support for intelligent analysis and diagnosis to optimize availability and reduce manual intervention This solution is available as part of Dell ProSupport and ProSupport Plus at no additional cost Provide REST interface API support for 3rd Party Integration Manage Server Configuration it is a fee based license available on Dell s 14th generation of PowerEdge servers ...

Page 60: ...rts Last Crash screen and video PowerEdge 14th gen servers Access Virtual Console and reduce the need for crash carts Power On Shut down or Reboot your server from anywhere Run any RACADM command OpenManage Power Center OpenManage Power Center is a one to many application that can read power usage and thermal readings information from Dell EMC servers Power Distribution Units PDU and Uninterruptib...

Page 61: ... and Distributed Management Task Force DMTF These APIs are widely used by commercial systems management products and by custom programs and scripts developed by IT staff to automate management functions such as discovery inventory health status checking configuration update and power management The APIs supported by iDRAC with Lifecycle Controller include Redfish In 2015 the DMTF Scalable Platform...

Page 62: ... server hardware and firmware You can perform these tasks through a dedicated Dell menu that can be accessed directly through the VMware vCenter console OMIVV also allows granular control and reporting for the hardware environment using the same role based access control model as vCenter The OpenManage Management Pack for vRealize Operations Manager is available with OMIVV v4 0 onwards This helps ...

Page 63: ... OpenManage Connection for Nagios Core and Nagios XI OpenManage Connection for HPE Operations Manager i OMi For more information on these OpenManage Connections visit Dell com openmanage 63 ...

Page 64: ...50 W Mixed Mode HVDC for China only Platinum 2891 BTU hr 50 60 Hz 100 240 V AC autoranging 750 W 750 W N A 10 A 5 A N A 2891 BTU hr N A 240 V DC autoranging N A N A 750 W 4 5 A 1100 W AC Platinum 4100 BTU hr 50 60 Hz 100 240 V AC autoranging 1100 W 1050 W N A 12 A 6 5 A 1100 W DC N A 4416 BTU hr N A 48 60 V DC autoranging N A N A 1100 W 32 A 1100 W Mixed Mode HVDC for China and Japan only Platinum...

Page 65: ...gher require high line voltage 200 240 V AC to supply their rated capacity System dimensions This section describes the physical dimensions of the system Figure 36 System dimensions of PowerEdge R7425 system Table 31 Dimensions System Xa Xb Y Za with bezel Za without bezel Zb Zc PowerEdge R7425 482 0 mm 18 98 inches 434 0 mm 17 09 inches 86 8 mm 3 42 inches 35 84 mm 1 41 inches 22 0 mm 0 87 inches...

Page 66: ...PowerEdge R7425 system supports integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer Table 33 Supported video resolution options Resolution Refresh rate Hz Color depth bits 1024 x 768 60 8 16 32 1280 x 800 60 8 16 32 1280 x 1024 60 8 16 32 1360 x 768 60 8 16 32 1440 x 900 60 8 16 32 1600 x 900 60 8 16 32 1600 x 1200 60 8 16 32 1680 x 1050 60 8 16 32 1920 x 1080 60 8 16 32...

Page 67: ...ry DDR4 SDRAM Specification jedec org standards documents docs jesd79 4 pdf PCI Express PCI Express Base Specification Rev 2 0 and 3 0 pcisig com specifications pciexpress PMBus Power System Management Protocol Specification v1 2 pmbus info specs html SAS Serial Attached SCSI v1 1 t10 org SATA Serial ATA Rev 2 6 SATA II SATA 1 0a Extensions Rev 1 2 sata io org SMBIOS System Management BIOS Referen...

Page 68: ... com Support Manuals Information Update This document ships with the system is also available in PDF format online and provides information on system updates Dell com Support Manuals System Information Label The system information label documents the system board layout and system jumper settings Text is minimized due to space limitations and translation considerations The label size is standardiz...

Page 69: ...ensive deployment tools to install configure and integrate your new solution optimally and correctly Our deployment experts will assess your environment and understand your goals then design and integrate your server solution for you Table 36 Server deployment capabilities Server Installation Server Integration Place single server in target workspace Yes Rack cable and label servers Yes Install im...

Page 70: ... organization Choose support models based on how you use technology and where you want to allocate resources From the desktop to the data center address everyday IT challenges such as unplanned downtime mission critical needs data and asset protection support planning resource allocation software application management and more Optimize your IT resources by choosing the right support model Figure ...

Page 71: ... tailored to suit your needs While not for everyone it offers a flexible solution for those with large and complex environments When you choose Dell EMC ProSupport Flex for Data Center you will get Enterprise wide support that covers your entire data center A dedicated Technical Account Manager with remote on site part time and full time options Dedicated elite ProSupport Flex technical and field ...

Page 72: ...rt duration projects that deliver return on investment ROI and free up resources The results are practical action oriented plans with specific predictable measurable outcomes From data center optimization to server virtualization to systems management our consulting services can help you build a more efficient enterprise Dell EMC managed services Dell EMC Managed Services are a modular set of life...

Reviews: