PSU specifications
The PowerEdge R7425 system supports up to two AC or DC power supply units (PSUs).
Table 30. PSU specifications
PSU
Class
Heat
dissipation
(maximum)
Frequency Voltage
High line
200v240 V
Low line
100– 140 V
DC
Current
495 W AC Platinum
1908 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
495 W
495 W
N/A
6.5 A–3 A
750 W AC
Platinum
2891 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
750 W
750 W
N/A
10 A–5 A
750 W AC
Titanium
2843 BTU/hr
50/60 Hz
200–240 V AC,
autoranging
750 W
N/A
N/A
5 A
750 W
Mixed
Mode
HVDC (for
China only)
Platinum
2891 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
750 W
750 W
N/A
10 A–5 A
N/A
2891 BTU/hr
N/A
240 V DC,
autoranging
N/A
N/A
750 W
4.5 A
1100 W AC Platinum
4100 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
1100 W
1050 W
N/A
12 A–6.5 A
1100 W DC N/A
4416 BTU/hr
N/A
–(48–60) V DC,
autoranging
N/A
N/A
1100 W 32 A
1100 W
Mixed
Mode
HVDC (for
China and
Japan
only)
Platinum
4100 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
1100 W
1050 W
N/A
12 A–6.5 A
N/A
4100 BTU/hr
N/A
200–380 V DC,
autoranging
N/A
N/A
1100 W 6.4 A–3.2 A
1600 W AC Platinum
6000 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
1600 W
800 W
N/A
10 A
2000 W
AC
Platinum
7500 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
2000 W
1000 W
N/A
11.5 A
2400 W
AC
Platinum
9000 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
2400 W
1400 W
N/A
16 A
64