background image

Manager (SCCM); and tools for optimizing management of Dell PowerEdge servers in virtual environments using System Center 
Virtual Machine Manager (SCVMM).

OpenManage Integration for VMware vCenter

The OpenManage Integration for VMware vCenter allows you to monitor, provision, and manage PowerEdge server hardware and 
firmware. You can perform these tasks through a dedicated Dell menu that can be accessed directly through the VMware vCenter 
console. OMIVV also allows granular control and reporting for the hardware environment using the same role-based access control 
model as vCenter. The OpenManage Management Pack for vRealize Operations Manager is available with OMIVV v4.0 onwards. 
This helps in checking hardware health and alerting into vRealize operations, which also includes dashboard and reporting on the 
server environment.

You can manage and monitor Dell hardware within the virtualized environment

Alerting and monitoring environment for servers and chassis

Monitoring and reporting for servers and chassis

Updating firmware on servers

Deploying enhanced options

For more information, see delltechcenter.com/omivv

NOTE: The Dell EMC Repository Manager integrates with OpenManage Integration for VMware vCenter. The Dell EMC 
Repository Manager provides advanced functionality, simplifies the discovery, and deployment of new updates.

BMC Software

Dell EMC and BMC Software work together to simplify IT by ensuring tight integration between Dell EMC server, storage, and 
network management functionality and the BMC Software process and data center automation products.

OpenManage connections with third-party consoles

Dell EMC OpenManage Connections gives you an easy path to adding support for third-party devices, so you can continue to use 
your existing management tools while easily adding Dell EMC server systems to your existing IT environment. Integrate new systems 
at your own pace. Manage new Dell EMC servers and storage with your legacy management tools, while extending the useful life of 
your existing resources. With OpenManage Connections you can add monitoring and troubleshooting of Dell EMC assets to your IT 
infrastructure.

OpenManage Connection for Nagios Core and Nagios XI

OpenManage Connection for HPE Operations Manager i (OMi)

For more information on these OpenManage Connections, visit 

Dell.com/openmanage

.

33

Summary of Contents for PowerEdge T140

Page 1: ...140 is the practical entry level 1 socket mini tower server that is easy to use and keeps your data safe It is ideal for growing businesses that primarily perform file and print mail and messaging and point of sale workloads Technical Guide ...

Page 2: ...8 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2018 10 Rev A00 ...

Page 3: ...atures 13 Supported processors 13 Chipset 14 5 Memory 16 Supported memory 16 Memory speed 16 Memory population and configuration 16 6 Storage 18 Supported hard drives 18 Storage Controller 19 Optical drive 19 Tape drive 19 vFlash and BOSS card 19 Boot Optimized Storage Subsystem BOSS 19 7 Networking and PCIe 20 PCIe slots 20 8 Power and acoustics 21 Power supply units 21 Acoustics 21 9 Supported o...

Page 4: ...endix B Standards compliance 37 13 Appendix C Additional resources 38 14 Appendix D Support and deployment services 39 ProDeploy Enterprise Suite and Residency Services 39 ProDeploy Plus 39 ProDeploy 39 Basic Deployment 39 Residency Services 40 Deployment services 40 Remote Consulting Services 40 Data Migration Service 40 ProSupport Enterprise Suite 40 ProSupport Plus 41 ProSupport 41 ProSupport O...

Page 5: ...f sale web serving and other collaboration and productivity applications ROBO Applications and workloads specific to the particular industry e g Retail Healthcare Finance Education etc Table 1 Detailed information of new technologies New technologies Description Intel C246 series chipset Please refer to the chipset section for details Intel Xeon processor E 2100 Product Family The Intel processor ...

Page 6: ...abled Hard drive types 3 5 Enterprise SATA 7 2K HDDs 3 5 Near Line SAS 7 2K HDDs 3 5 7 2K SATA Entry Drives 3 5 Enterprise SATA 7 2K HDDs 3 5 Near Line SAS 7 2K HDDs 3 5 7 2K SATA Entry Drives External drive bay s 1x slim ODD 9 5mm 1x slim ODD 9 5mm Embedded hard drive controller Chipset based SATA PERC S130 Embedded SW RAID Chipset based SATA PERC S140 Embedded SW RAID Optional storage controller...

Page 7: ...imension HxWxD Height 14 17 in 36 0 cm Width 6 89 in 17 5 cm Depth 17 9 in 45 4 cm Height 14 17 in 36 0 cm Width 6 89 in 17 5 cm Depth 17 9 in 45 4 cm Weight Max 24 91lbs or 11 3 Kgs Max 26 10lbs or 11 84 Kgs Specifications The following table shows the specifications for the PowerEdge T140 Table 2 Product specifications Feature Specifications Form Factor Mini Tower Processors Intel Xeon processor...

Page 8: ... Intel Dual Powerville Troi Stony Dual port 1Gb Base T adapter FH 1GB Intel Quad Powerville Lore Stony Quad port 1Gb Base T adapter FH 1GB Broadcom Dual 5720 Bashir Dual port 1Gb Base T adapter FH 1GB Broadcom Quad 5719 Cardassia Quad port 1Gb Base T adapter FH Power supply Cabled 365W Gold 100 240 V AC Availability ECC Memory ADD in RAID TPM CTPM Video Integrated Matrox G200 with iDRAC9 Remote Ma...

Page 9: ...hassis views and features Front view of the system Figure 1 Front view of the system 1 Power button 2 System health and ID indicator 3 USB 3 0 port 4 iDRAC direct micro USB port 5 Optical drive optional 9 ...

Page 10: ... and iDRAC secure password label 3 Service Tag Express Service Code QRL label 4 OpenManage Mobile OMM label 5 PCIe expansion card slots 4 6 USB 2 0 port 4 7 System identification button 8 NIC port Gb 2 9 USB 3 0 ports 2 10 NIC port Gb 1 11 iDRAC dedicated NIC port 12 VGA port 13 Serial port 14 Power supply unit 15 PSU Built in Self Test BIST LED 16 PSU Built in Self Test BIST Button 10 ...

Page 11: ...shipped with your product Figure 3 Inside the system 1 Cabled Power Supply Unit PSU 2 Optical drive 3 Cabled drives 4 4 System board 5 Expansion card retention latch 6 PCIe expansion card slots 4 7 Intrusion switch 8 Fan 9 Memory module sockets Locating the Service Tag of your system You can identify your system using the unique Express Service Code and Service Tag Pull out the information tag in ...

Page 12: ...Figure 4 Locating Service Tag of your system 1 Information tag top view 2 Information tag back view 3 OpenManage Mobile OMM label 4 iDRAC MAC address and iDRAC secure password label 5 Service Tag 12 ...

Page 13: ...on Technology Intel VT NOTE We do not support graphics with E 2100 processors Graphics cannot be enabled on Dell EMC servers using this processor due to technical restrictions Supported processors The following table lists the supported processors for the PowerEdge T140 Model Speed GHz Power Watts Cores L3 Cache MB Threads Turbo Max Memory Speed MT s Hyper threading E 2186G 3 8 95 6 12 12 Yes 2666...

Page 14: ... Y N Rapid Strorage technology Y N Rapid Strorage technology enterprise Y N Data Center Graphics N N supported displays 3 N Int Gbe MAC Y N eSPI Y N IO Flex ability to change SATA PCIE USB Y N Software Guard Extensions SGX N Y The following table shows the features supported by the T140 chipset Table 3 Chipset features Features Description DMI interface Direct Media Interface 3 DMI3 connects the C...

Page 15: ...rupts Each interrupt has its own unique vector assigned by software Real Time Clock RTC The Real Time Clock RTC performs two key functions keeping track of the time of day and storing system data even when the system is powered down The RTC operates on a 32 768 KHz crystal and a 3V battery General Purpose Input Output GPIO GPIO Serial Expander GSX is the capability provided by the chipset to expan...

Page 16: ...self refresh mode I C access to SPD EEPROM for access to thermal sensors Memory Optimized Independent Channel Mode 100 Single Bit Error Correction Memory Off lining is NOT supported Memory speed The PowerEdge T140 supports 2666MT s DDR4 memory This system will run all memory on all CPUs and channels at the same speed and voltage By default the system will run at the highest speed for the lowest vo...

Page 17: ... 2 2400 UDIMM 16 2 x8 Advanced ECC 1 2 2400 UDIMM 16 2 x8 Advanced ECC 1 2 2133 UDIMM 4 1 x8 Advanced ECC 1 2 2133 UDIMM 4 1 x8 Advanced ECC 1 2 2133 UDIMM 8 2 x8 Advanced ECC 1 2 2133 UDIMM 8 1 x8 Advanced ECC 1 2 2133 UDIMM 16 2 x8 Advanced ECC 1 2 2133 UDIMM 16 2 x8 Advanced ECC 1 2 The following table shows the memory populations and system speed Table 4 Memory populations and system speed DIM...

Page 18: ... selected in a NO RAID configuration Must not be used if the customer usage patterns require a workload rating that exceeds 55 TB year May induce compatibility issues depending on the OS due to the advanced format Entry level SATA hard drives in PowerEdge systems carry lesser of either a 1 year limited hardware warranty or the length of the limited hardware warranty for the Dell EMC system with wh...

Page 19: ...ng ability to boot from Tape drive The PowerEdge T140 do not support internal tape drives due to the form factor However external tape backup devices will be supported The list below shows the supported external tape drives LTO 6 SAS LTO 7 SAS LTO 8 SAS vFlash and BOSS card A SD vFlash card is a Secure Digital SD card that plugs into the SD vFlash card slot in the iDRAC port card It provides persi...

Page 20: ...om PCH x4 lanes The following table shows the PCIe slot location and specifications PCI Slot Mechanical Electrical Height Length 1 PCIe x 8 PCIe x 8 Gen 3 Full Height Half Length 2 PCIe x16 PCIe x 8 Gen 3 Full Height Half Length 3 PCIe x 1 PCIe x 1 Gen 3 Full Height Half Length 4 PCIe x 8 PCIe x 4 Gen 3 Full Height Half Length The following table shows the dimensions of the PCI cards Slots Height ...

Page 21: ...ondition Acoustical performance for two configurations are provided typical and feature rich The following tables contains a summary of the configuration and acoustical performance of the PET140 Each configuration has been tested according to Dell EMC acoustical standards for tower servers Configuration Minimum Typical Feature rich CPU Type Intel E2124 Intel E2124 Intel E2146G CPU TDP 71 W 71 W 80...

Page 22: ...ting Table 9 Acoustical performance Idle operating at 28 C ambient Configuration Minimum Typical Feature rich LwA UL Bels 3 9 3 9 3 9 LpA dBA 26 26 26 Table 10 Acoustical performance Max loading at 35 C ambient Configuration Minimum Typical Feature rich LwA UL Bels 5 2 5 2 5 2 LpA dBA 36 36 36 22 ...

Page 23: ...ystems for the PowerEdge T140 Windows 2019 with Hyper V Windows 2019 Essentials Windows 2016 with Hyper V Windows 2016 Essentials Windows 2012 R2 Enterprise Windows 2012 R2 Standard RHEL 7 5 SLES 15 Ubuntu Server 18 04 1 Citrix XenServer 7 1 VMWare ESXi 6 7 VMWare ESXi 6 5 23 ...

Page 24: ...ucts that help you automate and simplify the entire server lifecycle deploy update monitor and maintain OpenManage solutions are innovatively designed for simplicity and ease of use to help you reduce complexity save time achieve efficiency control costs and empower productivity OpenManage centers around efficient management of server lifecycle Figure 5 Server lifecycle management operations iDRAC...

Page 25: ...y Yes Yes Yes Yes Yes Yes Yes Yes Telnet Yes Yes Yes Yes Yes Yes Yes Yes SSH Yes Yes Yes Yes Yes Yes Yes Yes Serial redirection Yes Yes Yes Yes Yes Yes Yes Yes WSMAN Yes Yes Yes Yes Yes Yes Yes Yes Network Time Protocol No No Yes Yes Yes Yes Yes Yes Connectivity Shared NIC Yes Yes Yes Yes N A N A Yes Yes Dedicated NIC Yes Yes Yes Yes Yes Yes Yes Yes VLAN tagging Yes Yes Yes Yes Yes Yes Yes Yes IPv...

Page 26: ... default password No Yes No Yes No Yes No Yes Customizable Security Policy Banner login page No Yes No Yes No Yes No Yes Remote Presence Power control Yes Yes Yes Yes Yes Yes Yes Yes Boot control Yes Yes Yes Yes Yes Yes Yes Yes Serial over LAN Yes Yes Yes Yes Yes Yes Yes Yes Virtual Media No No No No Yes Yes Yes Yes Virtual Folders No No No No No No Yes Yes Remote File Share No No No No No No Yes ...

Page 27: ...Yes Yes Yes Yes Yes Yes Configurable thresholds Yes Yes Yes Yes Yes Yes Yes Yes Fan monitoring Yes Yes Yes Yes Yes Yes Yes Yes Power Supply monitoring Yes Yes Yes Yes Yes Yes Yes Yes Memory monitoring Yes Yes Yes Yes Yes Yes Yes Yes CPU monitoring Yes Yes Yes Yes Yes Yes Yes Yes RAID monitoring Yes Yes Yes Yes Yes Yes Yes Yes NIC monitoring Yes Yes Yes Yes Yes Yes Yes Yes HD monitoring enclosure Y...

Page 28: ...s Yes Yes Yes Yes Yes Yes Server Configuration Profile in GUI No Yes No Yes No Yes No Yes Diagnostics Service and Logging Embedded diagnostic tools Yes Yes Yes Yes Yes Yes Yes Yes Part Replacement No No Yes Yes Yes Yes Yes Yes Server Configuration Backup No No No No No No Yes Yes Server Configuration Restore Yes Yes Yes Yes Yes Yes Yes Yes Easy Restore system configuration Yes Yes Yes Yes Yes Yes ...

Page 29: ...management As Dell EMC PowerEdge servers have embedded server lifecycle management in many cases there is no need to install an OpenManage systems management software agent into the operating system of a Dell EMC PowerEdge server This greatly simplifies and streamlines the management footprint Agent based management Most systems management solutions require pieces of software called agents to be i...

Page 30: ...g a server operation automatically detect and notify any server or chassis drift from a customer defined baseline configuration Boot a system from a network mounted ISO using iDRAC Replicate of FN IOM and M IOA configurations within M1000e chassis Support VLAN Management for FN IOM and M IOA For more information see delltechcenter com OME OpenManage Mobile OpenManage Mobile OMM is a software appli...

Page 31: ...ell EMC OpenManage systems management tools and utilities consist of the following Dell EMC Repository Manager Dell EMC Repository Manager DRM is an application that helps you to Identify the updates that are relevant to the systems in your data center Identify and notify when updates are available Package the updates into different deployment format To automate the creation of baseline repositori...

Page 32: ...h the payload of the messages expressed in JSON and the OData v4 protocol WSMan The Web Services For Management WSMan API first published by the DMTF in 2008 is the most mature and robust API provided by iDRAC with Lifecycle Controller WSMan uses a Simple Object Access Protocol SOAP with data modeled using the Common Information Model WSMan provides interoperability between management applications...

Page 33: ...options For more information see delltechcenter com omivv NOTE The Dell EMC Repository Manager integrates with OpenManage Integration for VMware vCenter The Dell EMC Repository Manager provides advanced functionality simplifies the discovery and deployment of new updates BMC Software Dell EMC and BMC Software work together to simplify IT by ensuring tight integration between Dell EMC server storag...

Page 34: ...details of the PowerEdge T140 Xa Xb Ya Yb Yc Za with bezel Za without bezel Zb Zc Max Sys Wgt Kg 175 mm 6 89 inches N A 360 mm 14 17 inches 362 9 mm 14 29 inches N A 35 0mm 1 38 inches N A 400 0 mm 15 75 inches 418 75 mm 16 49 inches 11 84 Video The following list the video specifications for the PowerEdge T140 Video type Integrated Matrox G200 with iDRAC9 Video memory 16 MB shared with iDRAC9 app...

Page 35: ...s 3 5 Enterprise SATA 7 2K HDDs 3 5 Near Line SAS 7 2K HDDs 3 5 7 2K SATA Client Drives Capacity 1 TB 2 TB 4 TB NOTE 4TB requires PERC H330 or H730P NIC ports The PowerEdge T140 supports two 10 100 1000 Mbps NIC ports at the back panel Environmental specifications This section includes the environmental specifications for the PowerEdge T140 Feature Descriptions Temperature Maximum temperature grad...

Page 36: ...rage 1 88 Grms at 10 Hz to 500 Hz for 15 min allsix sides tested Maximum shock Operating Six consecutively executed shock pulses in the positive and negative x y and z axes of 31 G for up to 2 6 ms Storage One pulse on each side of the system of 71 G up to 2 ms Maximum altitude Operating 3 048 m 10 000 ft Storage 12 000 m 39 370 ft Operating Altitude De rating Up to 35 C 95 F Maximum temperature i...

Page 37: ...esign servers ipmi DDR4 Memory DDR4 SDRAM Specification jedec org standards documents docs jesd79 4 pdf PCI Express PCI Express Base Specification Rev 2 0 and 3 0 pcisig com specifications pciexpress PMBus Power System Management Protocol Specification v1 2 pmbus info specs html SAS Serial Attached SCSI v1 1 t10 org SATA Serial ATA Rev 2 6 SATA II SATA 1 0a Extensions Rev 1 2 sata io org SMBIOS Sy...

Page 38: ...ls Information Update This document ships with the system is also available in PDF format online and provides information on system updates Dell com Support Manuals System Information Label The system information label documents the system board layout and system jumper settings Text is minimized due to space limitations and translation considerations The label size is standardized across platform...

Page 39: ...onments Certified Dell EMC experts start with extensive environmental assessments and detailed migration planning and recommendations Software installation includes set up of most versions of Dell EMC SupportAssist and OpenManage system management utilities Post deployment configuration assistance testing and product orientation help you rest easy knowing your systems have been deployed and integr...

Page 40: ...point of contact to manage your data migration project Your project manager will work with our experienced team of experts to create a plan using industry leading tools and proven processes based on global best practices to migrate your existing files and data so your business gets up and running quickly and smoothly ProSupport Enterprise Suite With Dell EMC ProSupport Services we can help you kee...

Page 41: ...p you minimize disruptions and maximize availability of your PowerEdge server workloads with 24x7x365 access to certified hardware and software experts Collaborative 3rd party support Hypervisor and OS support Consistent level of support available for Dell EMC hardware software and solutions Onsite parts and labor response options including next business day or four hour mission critical ProSuppor...

Page 42: ...es with automated support Accelerate time to resolution receive issue alerts automatic case creation and proactive contact from Dell EMC experts Gain insight and control optimize enterprise devices with on demand ProSupport Plus reporting in TechDirect and get predictive issue detection before the problem starts SupportAssist is included with all support plans but features vary based on service le...

Page 43: ...ng Services Dell EMC Global Infrastructure Consulting Services use skilled solution architects innovative tools automated analysis and Dell EMC s intellectual property to give you rapid insight into the root causes of unnecessary complexity We seek better answers than traditional service models and our strategy is to help you quickly identify high impact short duration projects that deliver return...