Next step
Follow the procedure listed in
After working inside your system
Installing the power interposer board
Prerequisite
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Follow the safety guidelines listed in
Steps
1
Align the slots on the power interposer board (PIB) with the hooks on the power supply unit (PSU) cage and slide the PIB until it
snaps into place.
2
Secure the PIB to the chassis by using the screw.
3
Route the P3 power cable through the securing clip on the system board and connect power cable to the drive backplane.
Figure 84. Installing the power interposer board
Next steps
1
Install the cooling shroud.
134
Installing and removing system components