PCIe slot priority
Table 11. Supported card options
Category
Slot priority
Maximum number of
cards
Max PCIe Width Card length, Card height
PERC
1
1
X16
None
NIC
3
1
X16
None
NIC
3
1
X16
None
NIC
4
1
X16
Half length, Low profile
NIC
4
1
X16
Half length, Low profile
NIC
4
1
X16
Half length, Low profile
NIC
4
1
X16
Half length, Low profile
NIC
4
1
X16
Half length, Low profile
NIC
4
1
X16
Half length, Low profile
PERC
6
1
X8
Half length, Low profile
PERC
6
1
X8
Half length, Low profile
PERC
6
1
X8
Half length, Low profile
Processor and heat sink
Removing a processor and heat sink module
Prerequisites
WARNING:
The heat sink may be hot to touch for some time after the system is powered off. Allow the heat sink
to cool before removing it.
1. Follow the safety guidelines listed in the
.
2.
.
3.
.
Steps
1. Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order that is mentioned below:
a. Loosen the first screw three turns.
b. Loosen the second screw completely.
c. Return to the first screw and loosen it completely.
2. Pushing both blue retention clips simultaneously, lift the processor and heat sink module.
3. Set the processor and heat sink module aside with the processor side facing up.
Installing and removing system components
85