82
Brocade Adapters Troubleshooting Guide
53-1002145-01
Statistics
3
where:
<port_id>
ID of port for which you want to display statistics. This could be the PWWN,
port hardware path, or user-specified port name. This could also be the
adapter-index/port-index. For example, to specify adapter 1, port 1 you would
use 1/1 as the port identification.
Port Performance
Use the BCU port --perf command to display throughput information, in number of bytes received
and transmitted, for a specific physical port.
port --perf <port_range|all> [-c count] [-i interval]
where:
port_range
Port range to be displayed. If the range exceeds 80 columns, a warning
displays. The maximum ports within the 80 column limit will display. Specify
port range as the adapter number/port number-adapter number/port
number. For example, the range 1/0-2/0, includes adapter 1, port 0 and
adapter 2, port 0.
c
Count. The number of iterations of the display. The default behavior is to
continuously refresh. Use Ctrl-C to terminate.
-i
Interval. The sampling delay in seconds [default is 1 second]. The sampling
interval can be between 1 and 10.
ESX 5.0 systems
On ESX 5.0 and later systems, the port --perf will not work unless the -c option is used. The -c option
can be any number (limited by esxcli buffer size). For example, you can use the following:
esxcli brocade bcu --command=”port --perf -c 1”
For more information on using BCU commands on ESX 5.0 and later systems, refer to
“VMware ESX
5.0 and later systems”
on page 66
Port statistics
Use BCU and HCM to display a variety of port statistics. Following is an overview of port statistics
for different adapter types:
•
For HBAs and Fabric Adapter ports configured in HBA mode, statistics include transmitted and
received frames and words, received loop initialization primitive (LIP) event counts, error
frames received, loss of synchronization, link failure and invalid CRS counts, end of frame
(EOF) errors, encoding non-frame errors, and credit recovery statistics. Use these statistics to
isolate link and frame errors. For example, loss of synch and loss of signal errors indicate a
physical link problem. To resolve these problems, check cables, SFPs on adapters (stand-up
adapters only) or switch, and patch panel connections.
•
For CNAs and Fabric Adapter ports configured in CNA mode, statistics include total transmit
and receive counts for different sizes and types of frames. Data is included on 64-byte to
1519-1522-byte, multicast, broadcast, control, jabber, drop, control, FCS error, alignment error,
code error, pause MAC control, zero pause MAC control, FCoE pause MAC control, and zero
pause MAC control frames.
Summary of Contents for Brocade 815
Page 3: ...Brocade Adapters Troubleshooting Guide iii 53 1002145 01 ...
Page 4: ...iv Brocade Adapters Troubleshooting Guide 53 1002145 01 ...
Page 24: ...xxiv Brocade Adapters Troubleshooting Guide 53 1002145 01 ...
Page 136: ...112 Brocade Adapters Troubleshooting Guide 53 1002145 01 Adapter queries 3 ...
Page 144: ...120 Brocade Adapters Troubleshooting Guide 53 1002145 01 Tuning network drivers CNA or NIC 4 ...
Page 172: ...148 Brocade Adapters Troubleshooting Guide 53 1002145 01 ...