Powering Up
|
41
9
Powering Up
Before you supply power to the chassis, Dell Networking recommends that you re-inspect your
equipment rack and chassis. Verify that:
•
The equipment rack is properly secured and grounded.
•
The chassis is bolted and secured into your equipment rack.
•
Make sure the ambient temperature around the unit (which may be higher than the room temperature) is
within the limit specified for the unit.
•
Make sure there is sufficient airflow around the unit.
•
Make sure electrical circuits are not overloaded – consider the nameplate rating of all the connected
equipment, and make sure you have over current protection.
• At least one power supply module is installed.
• All power supply modules are properly installed.
• All power supply modules are switched to the
OFF
(left) position.
•
The remote power source complies with the input power specifications in the section
• AC Power cables connect to the remote power source (if applicable).
•
The fan tray is installed and cannot be removed by pulling on the fan tray handle.
• At least one RPM is installed.
• All line cards and RPMs are properly installed and secured.
• All chassis slots are filled. Blank panels and covers are installed in all empty slots.
•
Make sure no objects are placed on top of the unit.
To supply power to the C7004/C150 system:
WARNING:
Never operate the C7004/C150 System without a fan tray.
Step
Task
1
Verify that the power source complies with the system input power requirements in the section
2
Energize the remote power source or outlet.
3
Toggle the switch on the AC power supplies to the
ON
(right) position.
Summary of Contents for C7004/C150
Page 1: ...Installing and Maintaining the C7004 C150 System ...
Page 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 14: ...14 Preparing the Site w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 18: ...18 Installing the C7004 C150 Chassis w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 28: ...28 Management Cable Pinout w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 40: ...40 Installing DC Power Entry Modules w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 44: ...44 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 61: ...System Specifications 61 Figure B 2 Chassis Dimensions Depth 15 5 inches ...
Page 70: ...70 Contacting Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 71: ......
Page 72: ...w w w d ell com support dell com Printed in the U S A ...