58
|
Alarms
www.dell.com | support.dell.com
AC Power Supplies and Alarms
During system boot, if a redundant power supply is removed or fails, Dell Networking OS generates a
minor alarm message.
If only two power supplies are installed and one of them fails, Dell Networking OS generates an alarm
and an SNMP trap (if configured), and lights the RPM alarm LED and power supply LED.
Line card
Hardware failure
major (red)
major
amber
Exceeds high-temperature limit
major (red)
major
unlit
Exceeds warning temperature limit
minor (amber)
minor
green
Individual interface fails
minor (amber)
reported
amber
a
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit
major (red)
major
unlit
Exceeds warning temperature limit
minor (amber)
minor
green
RPM fails but Control Processor (CP) is OK
major (red)
major
amber
a.
Table A-1. Alarm Events and Reporting
Module
Alarm Event
Alarm LED
Reported in
event log
Status LED on
Module
Summary of Contents for C7004/C150
Page 1: ...Installing and Maintaining the C7004 C150 System ...
Page 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 14: ...14 Preparing the Site w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 18: ...18 Installing the C7004 C150 Chassis w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 28: ...28 Management Cable Pinout w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 40: ...40 Installing DC Power Entry Modules w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 44: ...44 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 61: ...System Specifications 61 Figure B 2 Chassis Dimensions Depth 15 5 inches ...
Page 70: ...70 Contacting Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 71: ......
Page 72: ...w w w d ell com support dell com Printed in the U S A ...