The control panel cable
is not connected, or is
improperly connected.
Reseat cables.
LCD screen message
No CMC
Found.
No CMC is present in the chassis.
Insert a CMC into the chassis or reseat
existing CMC if present.
Front Panel LCD Messages
This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages
on the LCD have a format that is similar to the System Event Log (SEL) viewed from the CLI or Web
interface.
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and
the possible cause of the message. Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information
on the LCD includes descriptive information about the modules in the chassis. The tables in this
section describe the information that is displayed for each component.
LCD Error Messages
Table 42. CMC Status Screens
Severity
Message
Cause
Critical
The CMC <number> battery failed.
CMC CMOS battery is missing or has no voltage.
Critical
CMC <number> LAN heartbeat was lost.
The CMC NIC connection has been removed or is not
connected.
Warning
A firmware or software incompatibility detected
between iDRAC in slot <number> and CMC.
Firmware between the two devices does not match in
order to support one or more features.
Warning
A firmware or software incompatibility detected
between system BIOS in slot <number> and
CMC.
Firmware between the two devices does not match in
order to support one or more features.
Warning
A firmware or software incompatibility detected
between CMC 1 and CMC 2.
Firmware between the two devices does not match in
order to support one or more features.
Table 43. Enclosure/Chassis Status Screen
Severity
Message
Cause
Critical
Fan <number> is removed.
This fan is required for proper cooling of the
enclosure/chassis.
Warning
Power supply redundancy is degraded.
One or more PSU have failed or removed and the
system can no longer support full PSU redundancy.
Critical
Power supply redundancy is lost.
One or more PSU have failed or removed and the
system is no longer redundant.
221
Summary of Contents for Chassis Management Controller
Page 1: ...Dell Chassis Management Controller Firmware Version 4 3 User s Guide ...
Page 42: ...42 ...
Page 56: ...56 ...
Page 84: ...84 ...
Page 98: ...98 ...
Page 104: ...104 ...
Page 130: ...130 ...
Page 136: ...136 ...
Page 200: ...200 ...
Page 214: ...214 ...