Table 22. System-diagnostic lights (continued)
Blinking pattern
Problem description
Suggested resolution
Amber
White
2
4
Memory/RAM failure
●
Reset and swap memory
modules among the slots.
●
If problem persists,
replace the memory
module.
2
5
Invalid memory installed
●
Reset and swap memory
modules among the slots.
●
If problem persists,
replace the memory
module.
2
6
System board/Chipset Error
Replace the system board.
2
7
LCD failure (SBIOS message)
Replace the LCD module.
2
8
LCD failure (EC detection of
power rail failure)
Replace the system board.
3
1
CMOS battery failure
●
Reset the main battery
connection.
●
If problem persists,
replace the main battery.
3
2
PCI or Video card/chip failure
Replace the system board.
3
3
BIOS Recovery image not
found
●
Flash latest BIOS version
●
If problem persists,
replace the system board.
3
4
BIOS Recovery image found
but invalid
●
Flash latest BIOS version
●
If problem persists,
replace the system board.
3
5
Power rail failure
Replace the system board.
3
6
Flash corruption detected by
SBIOS.
●
Press power button for
over 25 seconds to do
RTC reset. If problem
persists, replace the
system board.
●
Disconnect all power
source (AC, battery, coin
cell) and drain flea power
by pressing and holding
down power button 3~5
seconds to ensure all
power are drained.
●
Run "BIOS recovery from
USB", and the instructions
are in the website
.
●
If problem persists,
replace the system board.
3
7
Timeout waiting on ME to
reply to HECI message.
Replace the system board.
116
Troubleshooting
Summary of Contents for D03T
Page 13: ...Removing and installing components 13 ...
Page 87: ...Removing and installing components 87 ...
Page 89: ...Removing and installing components 89 ...
Page 90: ...90 Removing and installing components ...
Page 94: ...94 Removing and installing components ...