22
About Your System
E1114 Ambient Temp
exceeds
allowed range.
Ambient temperature has
a reached a point outside
of the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 147.
E1116 Memory
disabled, temp
above range.
Power cycle
AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 147.
If the problem persists,
see "Getting Help" on
page 169.
E1210 Motherboard
battery
failure. Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
See "Troubleshooting the
System Battery" on
page 146.
E1211 RAID
Controller
battery
failure. Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See
"Troubleshooting System
Cooling Problems" on
page 147.
E1216 3.3V Regulator
failure.
Reseat PCIe
cards.
3.3 V voltage regulator has
failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 155.
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage regulator
has failed.
Reseat the processor(s).
See "Troubleshooting the
Processors" on page 156.
If the problem persists,
see "Getting Help" on
page 169.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 22 Wednesday, December 22, 2010 2:13 PM
Summary of Contents for DX6000G
Page 1: ...Dell DX6000G Systems Hardware Owner s Manual ...
Page 8: ...8 Contents ...
Page 54: ...54 About Your System ...
Page 76: ...76 Using the System Setup Program and UEFI Boot Manager ...
Page 156: ...158 Troubleshooting Your System ...
Page 166: ...168 Jumpers and Connectors ...
Page 168: ...170 Getting Help ...