Environmental requirements
NOTE: Enclosure meets IP50 with the pre-installed PCIe
blank bracket. System IP rating depends on the PCIe
card IP rating.
Temperature range:
Operating (with a maximum temperature gradation of
15°C per hour)
-30°C to 70°C (-22°F to 158°F)
NOTE: The maximum operating temperature is derated
1°C/305 m(1000 ft) above sea level altitude.
NOTE: The enclosure meets this specification without a
PCIe card. Operating temperature may change if a PCIe
card is installed.
NOTE: Any component to be installed in the IO module
shall have a still air temperature rating that is equal to or
higher than the PCIe card temperature rating. For IO
modules without PCIe cards, use a system ambient
temperature of +3°C (+37.4°F) to determine the inside
air temperature.
Non-operating
-40°C to 85°C (-40°F to 185 °F)
Relative humidity (maximum):
Operating (with maximum humidity gradation of 10%
per hour)
10% to 90% (non-condensing)
Non-operating ((with maximum humidity gradation of
10% per hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating
-15.2 m to 5000 m (-50 ft to 16,404 ft)
NOTE: The maximum operating temperature is derated
1°C/305 m (1000 ft) above sea level altitude.
Storage
-15.20 m to 10,668 m (-50 ft to 35,000 ft)
Supported PCIe card power
—PCIe card temperatures and power ratings must meet following requirements:
66