background image

6

I/O Module Overview

The I/O module allows you to install a PCIe x1 card and adds additional ports to your Dell Edge Gateway.

NOTE: The power module is required to be installed with the Dell Edge Gateway to enable and use the I/O expansion 
module.

 

IO module (optional) views

IO module—Front

Features

1

IO module expansion connector and guide pin

Connect the IO module to the Edge Gateway.

2

Power status light

Indicates the power state of the IO module and the Edge 
Gateway.

72

Summary of Contents for Edge 5000 Series

Page 1: ...Dell Edge Gateway 5000 Series Installation and Operation Manual Computer Model Dell Edge Gateway 5000 5100 Regulatory Model N01G N02G Regulatory Type N01G001 N02G001 ...

Page 2: ... to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2017 05 Rev A02 ...

Page 3: ...structions d installation professionnelles 17 Federal Communication Commission Interference Statement 17 Industry Canada Statement 18 Setting up the Edge Gateway 19 Powering on the Edge Gateway 19 Mounting the Edge Gateway on the wall 22 Mounting the Edge Gateway on a DIN rail 24 Inserting a micro SIM card and activating your mobile broadband 26 4 Setting up your operating system 30 Windows 10 LTS...

Page 4: ...ations 56 Component types 56 Operating systems 56 Processor 56 Memory 57 Drives and removable storage 57 Communications WLAN antenna 57 Communications WWAN antenna 59 Graphics video controller 63 External ports and connectors 63 Dimensions and weight 64 Product dimensions and weight 64 Packaging dimensions and weight 64 Mounting dimensions 64 Environmental and operating conditions 65 Environmental...

Page 5: ...Bottom 82 Power module Top 84 Power module Right 85 Setting up the power module 85 Specifications Power Module 88 8 Enclosure Overview 90 Enclosure optional view 90 Enclosure Side 90 Setting up the enclosure 91 9 Setting up the ZigBee dongle 96 10 BIOS defaults 97 System configuration 97 Performance 97 Security 97 Power management 98 Maintenance 98 POST behavior 99 Cloud desktop 99 Wireless 99 11 ...

Page 6: ...and Wind River Linux operating systems As part of a complete interoperable building automation system Edge Gateway provides precise monitoring and control of connected points I O expansion module provide the Edge Gateway with additional inputs and output module The power expansion module provide the Edge Gateway with power redundancy options by allowing you to connect a 24V AC DC a 19 5V DC and a ...

Page 7: ... views System Front Features 1 Power button Press and hold for 2 seconds to turn on the system if it is turned off NOTE For more details about the LED indicators on the front of the system see LED indicators 7 ...

Page 8: ...ED Indicates the connectivity status and network activity 8 RS485 port status LED Provides the status of the RS485 port connections 9 RS485 port status LED Provides the status of the RS485 port connections 10 RS422 485 port status LED Provides the status of the RS422 485 port connections 11 CANbus port status LED Provides the status of the CANbus port connection 12 Serial port status LED Provides ...

Page 9: ...a broadband modem for network or internet access NOTE For more details about the DIP switches on the bottom of the system see DIP switches NOTE For RS422 and RS485 Termination is 120 ohms between the members of the differential pair when enabled Bias is 4 7k pull up 5V pull down Gnd when enabled Serial port RS232 connector mapping Pin Signal Pin Signal 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 R...

Page 10: ...the bias resistor for the RS422 RS485 port 4 ePSA diagnostic switch When the position of the switch changes the system starts in ePSA Enhanced Preboot System Assessment mode on the next start 5 RS485 port resistor switch Enable disable the differential termination resistor for RS485 6 RS485 port bias resistor switch Enable disable the bias resistor for the RS485 port 7 RS485 port resistor switch E...

Page 11: ...nnect an antenna to increase the range and strength of Wi Fi signals 5 Intrusion detection connector Connect an intrusion detection switch to detect any intrusion into the system 6 Wi Fi antenna port port four Connect an antenna to increase the range and strength of Wi Fi signals 7 HDMI port Connect a monitor or other HDMI device Provides video and audio output Hot plugging is supported on Windows...

Page 12: ...DS Data2 Shield 3 TMDS Data2 4 TMDS Data1 5 TMDS Data1 Shield 6 TMDS Data1 7 TMDS Data0 8 TMDS Data0 Shield 9 TMDS Data0 10 TMDS Clock 11 TMDS Clock Shield 12 TMDS Clock 13 CEC 14 Reserved 15 SCL 16 SDA 17 Ground 18 5 V min 0 055 A 19 Hot Plug Detect 12 ...

Page 13: ...xternal power module for increased power options 2 24 V AC DC power Phoenix connector Connect an 24 V AC DC power connector to provide power to your system 3 19 5 V DC power adapter port Connect a 19 5 V DC power adapter connector to provide power to your system 13 ...

Page 14: ...24 V AC DC power port 19 5 V DC power adapter port 14 ...

Page 15: ...System Right Features 1 IO expansion port Connect an external expansion module for additional IO ports 15 ...

Page 16: ...es from 0 8 to 2 5 mm 18 to 14 AWG WARNING The symbol indicates hot surface or adjacent hot surface that can obtain temperature during normal use that can cause a burn Allow equipment to cool off or use protective gloves when handling to reduce risk of a burn WARNING If a battery is included as part of System Network battery must be must be installed with appropriate enclosure in accordance with l...

Page 17: ...nce de sortie final ne dépasse pas les limites fixées dans les règles pertinentes La violation de ces règles pourrait conduire à des sanctions fédérales graves Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept a...

Page 18: ...ation is subject to the condition that this device does not cause harmful interference Cet appareil est conforme à la norme RSS 210 d Industrie Canada L opération est soumise à la condition que cet appareil ne provoque aucune interférence nuisible This device and its antenna s must not be co located or operating in conjunction with any other antenna or transmitter except tested built in radios Cet...

Page 19: ...0 5350 MHz et 5470 5725 MHz doit se conformer à la limite de p i r e 3 Le gain maximal d antenne permis pour les dispositifs utilisant la bande 5725 5825 MHz doit se conformer à la limite de p i r e spécifiée pour l exploitation point à point et non point à point selon le cas 4 Les pires angles d inclinaison nécessaires pour rester conforme à l exigence de la p i r e applicable au masque d élévati...

Page 20: ...4 Install the WWAN antenna to enable the wireless connections optional 5 Connect a display to the Edge Gateway if necessary 20 ...

Page 21: ...f accessing the Edge Gateway directly 7 Connect a grounding cable to the Gateway if necessary 8 Connect a SELV limited energy circuit power source to the Edge Gateway and press the power button to turn it on 24 V AC DC or 19 5 V DC 21 ...

Page 22: ...word for Ubuntu Snappy Core is ubuntu NOTE The default username and password for Wind River is root 10 Connect and configure devices using the RS422 RS485 ports NOTE Turn on the corresponding dip switches to enable the RS422 R485 ports NOTE After the Edge Gateway setup is complete reinstall the dust covers on any unused ports Mounting the Edge Gateway on the wall You can mount the Edge Gateway on ...

Page 23: ...that correspond to the holes in the mounting bracket then place the Edge Gateway against the wall and align the holes in the mounting brackets with the holes in the wall 3 Tighten the screws to secure the Edge Gateway to the wall 23 ...

Page 24: ...ail The DIN rail bracket mounts to the back of the Edge Gateway 1 Align the screw holes on the DIN rail mount to the back of the Edge Gateway place the screws on the DIN rail mount and secure it to the Edge Gateway 2 Pull down on the tab to release the latch on the DIN rail mount 24 ...

Page 25: ...3 Mount the Edge Gateway on a DIN rail 4 Secure the Edge Gateway to the DIN rail by pressing the latch 25 ...

Page 26: ...M card slot 3 Use a paper clip or SIM eject tool to eject the micro SIM card tray 4 Place the micro SIM card on the tray CAUTION Ensure that the micro SIM card is aligned as shown in the image 5 Close the micro SIM card tray 6 Turn on your Edge Gateway 7 Connect to a mobile network Windows operating system If the Edge Gateway is shipped with HSPA DW5580 WWAN card a Launch the Telit Mobile Broadban...

Page 27: ...ect to the mobile network nmcli con up connection name NOTE To view the IMEI and ICCID number use the mmcli m 0 command CIMI command To disconnect from the mobile network nmcli con downconnection name Wind River operating system If the Edge Gateway is shipped with HSPA DW5580 WWAN card a Open the Terminal window b Configure the Mobile Broadband APN profile uci set network wwan apn apn uci commit n...

Page 28: ...e root WR IntelligentDevice ifconfig wwan0 100 106 47 7 netmask 255 0 0 0 up root WR IntelligentDevice route add default gw 100 106 47 8 wwan0 root WR IntelligentDevice echo nameserver 198 224 157 135 etc resolv conf h Log in to the Minicom module using the minicom D dev ttyACM0 command i Connect to the mobile network using the at cgdata command Example at cgdata M RAW_IP 3 NOTE To view the IMEI a...

Page 29: ...e route add default gw gw_addr wwan0 root WR IntelligentDevice echo nameserver DNS_prim_addr etc resolv conf Example root WR IntelligentDevice ifconfig wwan0 100 106 47 7 netmask 255 0 0 0 up root WR IntelligentDevice route add default gw 100 106 47 8 wwan0 root WR IntelligentDevice echo nameserver 198 224 157 135 etc resolv conf i Log in to the Minicom module using the minicom D dev ttyACM0 comma...

Page 30: ...icense Agreement 5 Connect to an available wireless or wired network 6 Create a user account Restoring Windows 10 IoT Enterprise LTSB 2015 You can restore Windows 10 IoT Enterprise LTSB 2015 on the Edge Gateway using the recovery Operating System image on the boot partition which resets the run time image back to the factory image 1 Connect a keyboard mouse and monitor to the Edge Gateway 2 Power ...

Page 31: ...ing carrier SIM card for the system After the WWAN module and the SIM cards are installed 1 Click the Start Icon and then type Settings and open the Settings window 2 Select Network Internet from the Settings Menu 3 Locate the WWAN connection in the Wi Fi section and select the entry to connect and disconnect from the WWAN adapter HE910 Network configuration Follow the Service Manual to install an...

Page 32: ...n entirely new mechanism for managing a system and its applications The Edge Gateway supports the following list of Ubuntu Snappy Linux OS distribution Ubuntu Core 15 Ubuntu Core 16 For more information on Ubuntu Snappy Core OS see www ubuntu com cloud snappy www ubuntu com desktop snappy www ubuntu com internetofthings Pre requisites Infrastructure An active connection to the internet is needed t...

Page 33: ...n 19 SLN301761 Factory OS recovery image You can restore Ubuntu Snappy Core on the Edge Gateway using the recovery OS image on the boot partition Reset the system back to the factory image if you encounter any of the following situations You are unable to start the operating system The operating system is damaged Connect a keyboard mouse and monitor to the Edge Gateway or connect to the Edge Gatew...

Page 34: ...OS basic function Basic Commands NOTE For more information about Ubuntu commands see Snapcraft io Table 1 Basic commands Action Ubuntu Core 15 Ubuntu Core 16 Viewing system attributes sudo snappy info sudo snap version Updating the image to the latest Release sudo snappy update sudo snap update Viewing a list of all the snaps that are currently installed snaps sudo snappy search sudo snap find Vie...

Page 35: ...tect and recover system from malfunctions the design reacts by itself when system hangs unexpected crash Trusted Platform Module NOTE For more information about Trusted Platform Module see http www sat dundee ac uk psc watchdog Linux Watchdog html WDT is recommended to be default enabled to active the fail safe circuitry Snappy is a Watchdog Timer compatible OS provides capability to detect and re...

Page 36: ...posed to the host system and to the host OS as a USB HID device Software application developed to communicate with the GPIOs may use the protocol defined in following set of references to communicate with the GPIO modules There is no native application software available on the factory OS image that communicates with the IO Module GPIOs Zigbee NOTE This feature is only supported if hardware module...

Page 37: ...u Snappy make sure the system is connected to internet 2 Run the sudo snappy seach softap command to find the application from the Ubuntu Snappy Store 3 Run the sudo snappy install sw access point command to install the application After the snap is installed the service should be running as default configuration below SSID Ubuntu Open authentication 802 11n 2 4GHz G mode IP Address 10 0 60 1 DHCP...

Page 38: ...n the wireless module and it s associated driver to act as a wireless access point 1 Login to Ubuntu Snappy make sure the system is connected to internet 2 Run the sudo snap seach wifi ap command to find the application from the Ubuntu Snappy Store 3 Run the sudo snap install wifi ap command to install the application 4 After snap is installed run the sudo wifi ap config set wifi interface mlan0 t...

Page 39: ... b Click Erase c Select the first bootable partition on the USB device as the disk to use d The bootable partition should be formatted as either an FAT16 or FAT32 file system This is the default for most USB flash drives e Click Make Startup Disk The message USB drive created successfully is displayed 4 Unmount by right clicking on the USB device icon on the Unity launcher Choose Safely Remove the...

Page 40: ...the next screen select the BIOS file Edge_Gateway5000_1 X X exe on the USB key 9 Start the Flash process 10 Wind River Linux Overview The Edge Gateway is shipped with Wind River Linux IDP XT version 3 1 For more information on Wind River operating system see www windriver com support More generic details and references on running Wind River Linux IDP 3 1 on a Gateway product see www intel com gate...

Page 41: ...e Edge Gateway using the recovery OS image on the boot partition which resets the run time image back to the factory image if you encounter any of the following situations You are unable to start Wind River Linux The Wind River Linux operating system is damaged Connect a keyboard mouse and monitor to the Edge Gateway or connect to the Edge Gateway through a KVM session Dell Wyse Cloud Client Manag...

Page 42: ...x xxxx xxxxxxxxxxxx xxxx UEFI Capsule update capability Run the fwupgmgr tool commands are used to update UEFI BIOS firmware on the system The UEFI BIOS for this system is released through online Linux Vendor File System based methods Operation command root WR IDP xxxx fwupdmgr get devices Expected result Device found Device xxxx xxxxxxxx xxxx xxxx xxxx xxxxxxxxxxxx xxxx Watchdog Timer Running the...

Page 43: ...shown below System reboot To reboot the system as a root user logged in to the system enter the root WR IDP xxxx reboot reboot at the command prompt Expected result System reboots back to the login prompt successfully System PowerOff Run the root WR IDP xxxx shutdown now command to shuts down the system Expected result System shuts down successfully Network Interface To determine the default suppo...

Page 44: ...terface By default eth0 interface is configured to be DHCP client interface When this ethernet port is connected to a DHCP server this interface obtains an IP address from the DHCP server Run the root WR IDP xxxx ifconfig eth0 command to identify the IP address The network IP interface information is available under inet addr x x x x where x x x x is the IP address of the system eth1 Wired LAN int...

Page 45: ...e configuration Add on modules can be installed on the edge gateway system to get Wireless WAN WWAN connectivity 4G LTE Interface using Telit LE910 module for carrier AT T 4G LTE Interface using Telit LE910 module for carrier Verizon HSPA Interface using Telit HE910 module LE910 WWAN connection configuration Follow the Service Manual to install the LE910 module and the corresponding carrier SIM ca...

Page 46: ... command DESCRIPTION If the SIM is locked with a PIN the at cpin 1234 AT command can be used to unlock the SIM Where the SIM PIN is 1234 if the PIN is different use appropriate PIN number in the command below DESCRIPTION Setting up the APN NCM can be activated using every available CID NOTE Skip this step for Verizon as it is preprogrammed use AT CGDCONT to identify if the CID3 is vzwinternet The ...

Page 47: ...47 7 255 0 0 0 100 1 06 47 8 198 224 157 135 0 0 0 0 0 0 0 0 0 0 0 0 CGCONTRDP 3 7 vzwinternet mnc480 mcc311 gprs 254 128 0 0 0 0 0 0 0 0 0 71 4 6 110 1 1 255 255 255 255 255 255 255 255 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 198 224 157 135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OK A X Y root WR IntelligentDevice ifconfig wwan0 100...

Page 48: ...configuration Description Follow the hardware installation guide to install the HE910 module and the corresponding carrier SIM card in the system Once the hardware module and the SIM are installed follow the instructions below to activate 3G HSPA connectivity The HSPA connection on Wind River Linux can be activated using the following UCI command set or through LuCi web interface Below are samples...

Page 49: ...in the Gateway This portal can be used for performing variety of configuration functions on the Gateway along with using it for developing software layers on top of the base Wind River Linux OS Image sensor devices integration to the gateway and hardening of the combined application base OS image for deployment The developer portal has to be used for registering the Edge Gateway 5000 at Intel Mark...

Page 50: ...that came with factory installed Wind River Linux OS image to an internet connected router that can assign a DHCP address to the Gateway s ETH1 interface Make sure this connection has direct internet access outside of firewall and proxy connection during initial setup Login into the OS using default root root credentials on the Gateway Find out the IP address of the ETH1 interface using ifconfig I...

Page 51: ...ntel Wind River If you have not gotten such email contact your sales contact at Dell to get you through the registration process to obtain credentials for the Windshare repository When the WindShare credentials are entered additional set of repositories from where packages can be downloaded are added to the channel list The additional set of channels can be reviewed by using the smart command in t...

Page 52: ...at the Windshare repository At this point the user should have an environment ready to develop other layers of applications on top of the Gateway 5000 system Below are some of the sample screenshots of the Developer Hub web interface described in the steps above Below are some of the sample screenshots of the Developer Hub web interface described in the steps above 52 ...

Page 53: ...inal dev ttyS2 Edge Gateway I O Module GPIO Mapping Description The GPIOs on the Gateway are managed through GPIO driver on the OS The cloud LED on the Gateway is attached to one of the GPIOs and below are the steps on how to control the cloud LED in Wind River Linux OS 1 Export Cloud LED PIN root WR IDP XXXX echo 346 sys class gpio export root WR IDP XXXX echo out sys class gpio gpio346 direction...

Page 54: ...cription The Edge Gateway supports a USB Zigbee dongle as an optional add on hardware When the Zigbee dongle is present on the system it is enumerated to the OS as a USB device and accessed through cdc_acm kernel driver layer on the Wind River Linux host There are no native application software on the factory installed OS image to perform Zigbee protocol for this device A basic communication with ...

Page 55: ...n the Wind River Linux host There are no native application software on the factory installed OS image to perform CAN protocol for this device The CAN module presence on the Gateway can be identified by issuing lsusb command in the Linux prompt and looking for Microchip Technology Inc based device For CAN communication protocols and software API references a separate set of references and articles...

Page 56: ...I O Fintek F81960D I Fintek F81960D I LAN on system board Realtek RTL81191 CG Realtek RTL81191 CG TPM Nuvoton NPCT6SO series Nuvoton NPCT6S4 series SSD 60D3 LITEON 60D3 LITEON WLAN MURATA LBEE5ZZ1EN MURATA LBEE5ZZ1EN WWAN TELIT HE910 TELIT LE910 SV TELIT LE910 TELIT HE910 TELIT LE910 SV TELIT LE910 Coin cell battery CR2032 BR2032 Operating systems Supported operating systems Microsoft Windows 10 I...

Page 57: ...billion bytes actual capacity varies with pre loaded material and operating environment and will be lower Communications WLAN antenna General specifications Antenna type PCB Dipole Number of ports 2 Frequency GHz 2 4 to 2 5 4 9 to 5 9 Voltage Standing Wave Ratio VSWR 2 1 2 1 Isolation dB 20 20 Peak gain 3 5 dBi 5 0 dBi Average gain on sphere 3D 4 dBi 5 dBi Polarization Linear Efficiency 55 55 Mech...

Page 58: ...tric outer diameter 2 79 mm 0 076 mm 0 110 in 0 003 in Velocity of propagation 80 Center conductor Solid copper 0 94 mm 0 025 mm 0 037 in 0 001 in Shield 1 Foil aluminium poly tape adhered to dielectric Diameter over foil 3 02 mm 0 07 mm 0 119 in 0 003 in Shield 2 Braid 90 36 AWG tin copper Outer jacket Plenum PVDF off white lead free and UV stable Outer diameter 4 52 mm 0 15 mm 0 178 in 0 006 in ...

Page 59: ...791 862 824 894 880 960 1710 1880 1850 1990 1710 2155 1920 2170 2500 2690 VSWR 2 1 Isolation dB 15 Peak gain 5 0dBi 5 0dBi 5 0dBi 3 7dBi 5 0dBi 3 3dBi 3 3dBi 5 0dBi 5 0dBi Average gain on sphere 3D 3 dBi Polarization Linear Efficiency 40 Mechanical and environmental specifications Height 254 mm 10 in Diameter 41 mm 1 61 in Weight 820 g with mounting holder IPX class IP65 Mounting Wall mounted Conn...

Page 60: ...ric Diameter over foil 3 02 mm 0 07 mm 0 119 in 0 003 in Shield 2 Braid 90 36 AWG tin copper Outer jacket Plenum PVDF off white lead free and UV stable Outer diameter 4 52 mm 0 15 mm 0 178 in 0 006 in Outer Jacket Plenum PVDF Off white lead free and UV stable Outer Diameter 4 52 mm 0 15 mm 0 178 in 0 006 in PLENUM rating CMP ETL C ETL Attenuation dB 100 feet nominal reference values 8 0 dB 450 MHz...

Page 61: ...9 746 0 38 0 92 1 00 1 03 734 0 49 1 12 1 16 1 10 740 0 67 1 42 1 39 1 11 746 0 95 1 56 1 51 1 20 756 1 48 2 10 1 63 1 53 765 1 81 2 42 1 64 1 63 772 1 93 2 47 1 40 1 57 777 2 00 2 50 1 33 1 60 782 1 85 2 36 1 02 1 48 787 1 67 2 25 0 73 1 43 791 1 62 2 21 0 90 1 37 806 1 69 2 34 1 68 1 61 821 1 70 2 02 1 97 1 91 824 1 63 1 93 1 91 1 91 836 1 65 1 65 1 80 1 71 849 1 63 1 46 1 79 1 40 862 1 65 1 34 ...

Page 62: ...8 1 76 0 66 1 50 1805 0 40 1 59 0 34 1 26 1840 0 12 1 49 0 01 1 18 1850 0 06 1 58 0 04 1 18 1880 0 36 1 65 0 51 1 49 1910 0 72 1 76 0 90 1 81 1920 0 86 1 85 0 91 1 99 1930 1 01 1 89 0 95 2 15 1950 1 29 2 16 0 99 2 28 1960 1 23 2 32 0 91 2 29 1980 0 98 2 43 0 95 2 19 1995 0 35 2 22 0 74 1 80 2110 0 72 1 06 1 37 1 28 2140 0 82 1 08 1 58 1 31 2170 1 15 1 22 1 85 1 18 2300 2 23 2 40 2 97 1 63 2325 1 7...

Page 63: ...0 1 98 2 20 2 02 2 59 2690 2 07 2 38 2 17 2 55 Graphics video controller 5000 5100 Intel integrated graphics External ports and connectors NOTE For locations of ports and connectors see system views NOTE For RS422 and RS485 Termination is 120 ohms between the members of the differential pair when enabled Bias is 4 7k pull up 5V pull down Gnd when enabled 5000 5100 RS 232 1 RS 485 2 RS 422 RS 485 c...

Page 64: ...2 93 in 47 70 mm 1 88 in 64 20 mm 2 53 in 79 80 mm 3 14 in NOTE The dimensions for the enclosure do not include the latches and wall bracket on the back of the enclosure The wall bracket adds 5 mm 0 04 inches to the depth Packaging dimensions and weight 5000 5100 IO Module Power module IP65 rugged enclosure Height 34 4 cm 13 56 in 34 4 cm 13 56 in 25 4 cm 10 in 25 4 cm 10 in 52 7 cm 20 75 in Width...

Page 65: ...urce 30 C to 70 C 22 F to 158 F when connected to a power adapter or battery NOTE The maximum operating temperature is derated 1 C 305 m 1000 ft above sea level altitude Non operating with a maximum temperature gradation of 15 C per hour 40 C to 85 C 40 F to 185 F Relative humidity maximum Operating with maximum humidity gradation of 10 per hour 10 to 90 non condensing Non operating with maximum h...

Page 66: ...perature rating that is equal to or higher than the PCIe card temperature rating For IO modules without PCIe cards use a system ambient temperature of 3 C 37 4 F to determine the inside air temperature Non operating 40 C to 85 C 40 F to 185 F Relative humidity maximum Operating with maximum humidity gradation of 10 per hour 10 to 90 non condensing Non operating with maximum humidity gradation of 1...

Page 67: ...on to calculate the maximum supported power NOTE If a PCIe card is rated at a temperature greater than 85 C it shall be treated as an 85 C rated card in determining the supported power Environmental conditions Power module Environmental requirements Ingress protection rating IP50 Temperature range Operating with a maximum temperature gradation of 15 C per hour 30 C to 70 C 22 F to 158 F when conne...

Page 68: ...is derated 18 C 32 4 F under direct solar thermal load Non operating with a maximum temperature gradation of 15 C per hour 40 C to 85 C 40 F to 185 F Relative humidity maximum Operating with maximum humidity gradation of 10 per hour 10 to 90 non condensing Non operating with maximum humidity gradation of 10 per hour 5 to 95 non condensing Altitude maximum unpressurized Operating 15 2 m to 5000 m 5...

Page 69: ...Hz 63 Hz Average efficiency ESTAR 5 2 compliant 87 DC parameters 19 5 v output 19 5 V 3 34 A Total power maximum 65 W BTUs h based on PSU max wattage 222 BTU Power input tolerances 24V AC DC 10 to 25 26 4 V to 18 V Power module Battery connector Charging Charging shuts down when the battery voltage reaches 14 V Powering the system System will shutdown is the voltage from the battery is below 10 V ...

Page 70: ...e When enclosure door is opened a message appears in the BIOS during Power On Self Test POST indicating door is open A log is also created NOTE TPM is not available in all countries Depending on your country regulations TPM system boards may be unavailable Software 5000 5100 Dell Edge Device Manager systems management Optional Environmental NOTE For more details on Dell environmental features see ...

Page 71: ...ttn Warranties One Dell Way Round Rock TX 78682 For more information visit www dell com warranty NOTE Service may be provided by third party A technician will be dispatched if necessary following phone based troubleshooting Subject to parts availability geographical restrictions and terms of service contract Service timing dependent upon time of day call placed to Dell U S 71 ...

Page 72: ...power module is required to be installed with the Dell Edge Gateway to enable and use the I O expansion module IO module optional views IO module Front Features 1 IO module expansion connector and guide pin Connect the IO module to the Edge Gateway 2 Power status light Indicates the power state of the IO module and the Edge Gateway 72 ...

Page 73: ...232 port Connect an RS232 cable 6 Cable routing slot Route any cable s that has to be connected to the PCI card installed in the IO module GPIO connector mapping Pin Signal PIC Pin Full Pin Name 1 GND 2 GPIO 1 AN22 RPE5 PMD5 RE5 3 GPIO 2 AN23 PMD6 RE6 4 GPIO 3 AN27 PMD7 RE7 5 GPIO 4 AN16 C1IND RPG6 SCK2 PMA5 RG6 6 GPIO 5 AN17 C1INC RPG7 PMA4 RG7 7 GPIO 6 AN18 C2IND RPG8 PMA3 RG8 8 GPIO 21 AN8 RPB8...

Page 74: ...touching anything inside the system ground yourself by touching an unpainted metal surface While you work periodically touch an unpainted metal surface to dissipate static electricity which could harm internal components NOTE Install the PCIe expansion card in the IO expansion module before mounting it on wall mount or DIN rail 1 Install the PCIe expansion card in the IO expansion module optional ...

Page 75: ...dule guide pins to the power module port on the Edge Gateway and slide the power module toward the Edge Gateway until fully seated 5 Ensure the top and bottom latches are locked to secure the module to the Edge Gateway 75 ...

Page 76: ...e Gateway and the IO module along with the power module at a desired location using a wall mount bracket or the DIN rail mount Wall mount bracket DIN rail mount 7 Connect to a power source and press the power button 76 ...

Page 77: ...an harm your device and potentially cause it not to function properly Ensure that you are properly grounded before handling the mobile broadband card NOTE Install the PCIe expansion card in the IO expansion module before mounting it on a wall mount or DIN rail 1 Open the IO module a Remove the dust caps and loosen the access cover screw that secures the IO expansion module to the cover b Slide the...

Page 78: ...2 Remove the PCIe expansion card slot cover 3 Install the PCIe card into the PCIe expansion card slot on the IO expansion module and secure with a screw 4 Replace the cover on the IO expansion module 78 ...

Page 79: ...5 Tighten the screw that secures the cover to the IO expansion module NOTE Replace the dust caps on any unused ports and connectors 79 ...

Page 80: ... to your Dell Edge Gateway The power module allows you to connect to all three power sources that is the 24V AC DC 19 5 VDC and a battery NOTE The Power Module is required to be installed with the Dell Edge Gateway to enable and use the I O expansion module Power module optional views 80 ...

Page 81: ...Power module Front Features 1 Power status LED Indicates the power state of the power module and the Edge Gateway 2 Battery status LED Indicates the power state of the attached battery 81 ...

Page 82: ...port Connect a 24 V AC DC power source to power your Edge Gateway 3 Sealed lead acid battery port Connect an external battery to the power module to provide back up power in case of power interruption 4 Bottom release latch Push both the top and bottom release latches to disconnect the power module from the Edge Gateway 19 5 V DC power adapter port 82 ...

Page 83: ...24 V AC DC power port Sealed lead acid battery port 83 ...

Page 84: ...Power module Top Features 1 Top release latch Push both the top and bottom release latches to disconnect the power module from the Edge Gateway 84 ...

Page 85: ...module WARNING Before installing the power module shut down the Edge Gateway and disconnect the power cable NOTE To enable and use the IO expansion module you must also install the power module 1 Attach either wall mount brackets or a DIN rail mounts to the power module as needed 2 Remove the screw and the dust cap covering the power module expansion port on the Edge Gateway connector 85 ...

Page 86: ...to the power module port on the Edge Gateway and slide the power module until fully seated 4 Ensure the top and bottom latches are locked to secure the module to the Edge Gateway 5 Secure the power module to the wall or to the DIN rail 86 ...

Page 87: ...Wall mount bracket DIN rail 6 Connect the power sources and press the power button on the Edge Gateway 87 ...

Page 88: ...ule Dimensions Height 117 80 mm 4 64 inches Width 216 mm 8 50 inches Depth 64 20 mm 2 53 inches Power requirements Terminal block connector input voltage current 24 VAC 50 Hz 60 Hz or 24 VDC 15A Power adapter input voltage current 19 5 VDC 6 67A Battery connector port 12VDC 15A Environmental requirements Ingress Protection Rating IP50 Temperature range Operating with a maximum temperature gradatio...

Page 89: ...mum Operating with maximum humidity gradation of 10 per hour 10 to 90 non condensing Non operating with maximum humidity gradation of 10 per hour 5 to 95 non condensing Altitude maximum unpressurized Operating 15 2m to 5000m 50ft to 16 404ft NOTE The maximum operating temperature is derated 1 C 305m 1000ft above sea level altitude Storage 15 20 m to 10 668 m 50 ft to 35 000 ft 89 ...

Page 90: ...d humidity Enclosure optional view Enclosure Side Features 1 Rugged enclosure Install the Edge Gateway in the rugged enclosure when using in harsh environments condition 2 Intrusion detection switch Detects unauthorized system access 3 Door securing latch 3 Secure the enclosure 4 Thermal ribs Dissipates the heat generated by the system 5 Latch lock out Secure the system with a padlock 90 ...

Page 91: ...oor stop cables 2 Restricts the door from opening 11 Door thermal ribs Dissipates the heat generated by the system Setting up the enclosure 1 Install the enclosure s wall mount bracket at a desired location and secure it to the wall using the wall mount screws NOTE Ensure that the notch on the bracket is on the top NOTE The wall mount screws are not included with the enclosure 2 Open the enclosure...

Page 92: ...ounting brackets to the Edge Gateway by using the screws NOTE Before attaching the brackets to the Edge Gateway note the correct orientation of the brackets 6 Position the Edge Gateway onto the enclosure s two locator pins and then place and tighten the screws to secure the Edge Gateway to the enclosure 92 ...

Page 93: ...ch to the system 8 Remove the desired conduit plugs on the bottom or the left side of the enclosure and install the wiring conduits NOTE To ensure that dust and water does not enter the enclosure install a conduit rated as IP65 93 ...

Page 94: ...through the conduits and connect the cables to the desired connectors NOTE To reduce the risk of accidental cable disconnection tie all cables to the cable tie off guides 10 Close and securely latch the enclosure door 94 ...

Page 95: ...95 ...

Page 96: ... IO expansion module 1 Shut down your Edge Gateway 2 Connect the ZigBee dongle to any external USB port on your Edge Gateway or Connect the ZigBee dongle to any external USB port on the IO module NOTE Do not connect the ZigBee dongle to the internal USB port of the IO expansion module 3 Turn on the Edge Gateway and complete the setup NOTE For ZigBee development information see www silabs com 96 ...

Page 97: ...t USB ports rear USB ports Enable boot support front USB ports rear USB ports Performance 5000 5100 Multiple core support All All Intel SpeedStep Enable Enable C states control Enable Enable Limit CPUID value Disable Disable Intel TurboBoost Enable Enable Rapid Start Technology Enable Enable HyperThread control Enable Enable Security 5000 5100 Internal HDD password Not set Not set Strong password ...

Page 98: ... hibernation S4 and power off S5 state Disable Turns the system on from hibernation S4 and power off S5 state Block sleep Disable Disable Intel ready mode Disable Disable NOTE With USB wake support from power off S5 a wired keyboard or mouse is able to wake the system if connected to the designated USB port marked with the Smart Power On icon For wireless keyboard and mice if both devices share th...

Page 99: ...s 255 255 255 255 255 255 255 255 Server port 06910 06910 Client address method DHCP DHCP Client IP address 255 255 255 255 255 255 255 255 Client subnet mask 255 255 255 255 255 255 255 255 Client gateway 255 255 255 255 255 255 255 255 DNS IP address 255 255 255 255 255 255 255 255 Advanced Disable Disable Wireless 5000 5100 Wireless device enable Enable WLAN WWAN Bluetooth Enable WLAN WWAN Blue...

Page 100: ...tps www dell com support manuals Dell Edge Device Manager Getting Started Guide Dell SupportAssist For Dell OpenManage Essentials Quick Start Guide Dell Command Monitor User s Guide Additionally for more information on using Dell Data Protection Encryption see the documentation for the software at https www dell com support manuals 100 ...

Page 101: ...ry and environmental compliance Product related conformity assessment and regulatory authorizations including Product Safety Electromagnetic Compatibility EMC Ergonomics and Communication Devices relevant to this product as well as the Data Sheet for this product are available at dell com regulatory_compliance Details of Dell s environmental stewardship program to conserve product energy consumpti...

Reviews: